Importance of the Webb, Pearman, and Leuning (WPL) correction for the measurement of small CO 2 fluxes

The WPL (Webb, Pearman, and Leuning) correction is fully accepted to correct trace gas fluxes like CO 2 for density fluctuations due to water vapour and temperature fluctuations for open-path gas analysers. It is known that this additive correction can be on the order of magnitude of the actual flux...

Full description

Bibliographic Details
Published in:Atmospheric Measurement Techniques
Main Authors: K. Jentzsch, J. Boike, T. Foken
Format: Article in Journal/Newspaper
Language:English
Published: Copernicus Publications 2021
Subjects:
Online Access:https://doi.org/10.5194/amt-14-7291-2021
https://doaj.org/article/86b0c568e7244de090aab8a4e3bb3c86
Description
Summary:The WPL (Webb, Pearman, and Leuning) correction is fully accepted to correct trace gas fluxes like CO 2 for density fluctuations due to water vapour and temperature fluctuations for open-path gas analysers. It is known that this additive correction can be on the order of magnitude of the actual flux. However, this is hardly ever included in the analysis of data quality. An example from the Arctic shows the problems, because the size of the correction is a multiple of the actual flux. As a general result, we examined and tabulated the magnitude of the WPL correction for carbon dioxide flux as a function of sensible and latent heat flux. Furthermore, we propose a parameter to better estimate possible deficits in data quality and recommend integrating the quality flag derived with this parameter into the general study of small carbon dioxide fluxes.