TEMPERATURE ANALYSIS OF HIGH LATITUDES AND LOW ALTITUDE ISLAND PERMAFROST DURING THE CONSTRUCTION OF CFG PILE
Cement fly ash gravel (CFG) pile composite foundation is an effective and economic foundation treatment approach, which is significant to building a foundation, subgrade construction, and so forth. The present paper aims to investigate the temperature behaviours of high latitudes and low altitude is...
Published in: | Stavební obzor - Civil Engineering Journal |
---|---|
Main Authors: | , |
Format: | Article in Journal/Newspaper |
Language: | English |
Published: |
Czech Technical University, Prague
2018
|
Subjects: | |
Online Access: | https://doi.org/10.14311/CEJ.2018.03.0024 https://doaj.org/article/85268746e68747b0985245f288ade415 |
id |
ftdoajarticles:oai:doaj.org/article:85268746e68747b0985245f288ade415 |
---|---|
record_format |
openpolar |
spelling |
ftdoajarticles:oai:doaj.org/article:85268746e68747b0985245f288ade415 2023-08-27T04:11:28+02:00 TEMPERATURE ANALYSIS OF HIGH LATITUDES AND LOW ALTITUDE ISLAND PERMAFROST DURING THE CONSTRUCTION OF CFG PILE Liu Jin-liang Jia Yan-min 2018-10-01T00:00:00Z https://doi.org/10.14311/CEJ.2018.03.0024 https://doaj.org/article/85268746e68747b0985245f288ade415 EN eng Czech Technical University, Prague http://civilengineeringjournal.cz/archive/issues/2018/2018_3/3-2018-0024-(291-306)-Final.pdf https://doaj.org/toc/1805-2576 doi:10.14311/CEJ.2018.03.0024 1805-2576 https://doaj.org/article/85268746e68747b0985245f288ade415 Civil Engineering Journal, Vol 2018, Iss 3, Pp 291-306 (2018) High latitudes and low altitude island permafrost CFG pile composite foundation Temperature monitoring Finite element model Height of subgrade Engineering (General). Civil engineering (General) TA1-2040 article 2018 ftdoajarticles https://doi.org/10.14311/CEJ.2018.03.0024 2023-08-06T00:45:33Z Cement fly ash gravel (CFG) pile composite foundation is an effective and economic foundation treatment approach, which is significant to building a foundation, subgrade construction, and so forth. The present paper aims to investigate the temperature behaviours of high latitudes and low altitude island permafrost when the CFG pile was constructed, in which FEM and field temperature monitoring of permafrost was utilized. The proposed findings demonstrate that the temperature disturbance of permafrost is obvious when the CFG pile was constructed, and the temperature variation of CFG pile and permafrost in FEM has a good agreement with the results of field temperature monitoring. Additionally, the influence of different height subgrade on the temperature field of CFG pile composite foundation was analyzed by FEM. The proposed findings demonstrate that the height of subgrade affects the maximum temperature increase of permafrost and the re-frozen time of permafrost after the construction of CFG pile composite foundation. Article in Journal/Newspaper permafrost Directory of Open Access Journals: DOAJ Articles Stavební obzor - Civil Engineering Journal 27 3 291 306 |
institution |
Open Polar |
collection |
Directory of Open Access Journals: DOAJ Articles |
op_collection_id |
ftdoajarticles |
language |
English |
topic |
High latitudes and low altitude island permafrost CFG pile composite foundation Temperature monitoring Finite element model Height of subgrade Engineering (General). Civil engineering (General) TA1-2040 |
spellingShingle |
High latitudes and low altitude island permafrost CFG pile composite foundation Temperature monitoring Finite element model Height of subgrade Engineering (General). Civil engineering (General) TA1-2040 Liu Jin-liang Jia Yan-min TEMPERATURE ANALYSIS OF HIGH LATITUDES AND LOW ALTITUDE ISLAND PERMAFROST DURING THE CONSTRUCTION OF CFG PILE |
topic_facet |
High latitudes and low altitude island permafrost CFG pile composite foundation Temperature monitoring Finite element model Height of subgrade Engineering (General). Civil engineering (General) TA1-2040 |
description |
Cement fly ash gravel (CFG) pile composite foundation is an effective and economic foundation treatment approach, which is significant to building a foundation, subgrade construction, and so forth. The present paper aims to investigate the temperature behaviours of high latitudes and low altitude island permafrost when the CFG pile was constructed, in which FEM and field temperature monitoring of permafrost was utilized. The proposed findings demonstrate that the temperature disturbance of permafrost is obvious when the CFG pile was constructed, and the temperature variation of CFG pile and permafrost in FEM has a good agreement with the results of field temperature monitoring. Additionally, the influence of different height subgrade on the temperature field of CFG pile composite foundation was analyzed by FEM. The proposed findings demonstrate that the height of subgrade affects the maximum temperature increase of permafrost and the re-frozen time of permafrost after the construction of CFG pile composite foundation. |
format |
Article in Journal/Newspaper |
author |
Liu Jin-liang Jia Yan-min |
author_facet |
Liu Jin-liang Jia Yan-min |
author_sort |
Liu Jin-liang |
title |
TEMPERATURE ANALYSIS OF HIGH LATITUDES AND LOW ALTITUDE ISLAND PERMAFROST DURING THE CONSTRUCTION OF CFG PILE |
title_short |
TEMPERATURE ANALYSIS OF HIGH LATITUDES AND LOW ALTITUDE ISLAND PERMAFROST DURING THE CONSTRUCTION OF CFG PILE |
title_full |
TEMPERATURE ANALYSIS OF HIGH LATITUDES AND LOW ALTITUDE ISLAND PERMAFROST DURING THE CONSTRUCTION OF CFG PILE |
title_fullStr |
TEMPERATURE ANALYSIS OF HIGH LATITUDES AND LOW ALTITUDE ISLAND PERMAFROST DURING THE CONSTRUCTION OF CFG PILE |
title_full_unstemmed |
TEMPERATURE ANALYSIS OF HIGH LATITUDES AND LOW ALTITUDE ISLAND PERMAFROST DURING THE CONSTRUCTION OF CFG PILE |
title_sort |
temperature analysis of high latitudes and low altitude island permafrost during the construction of cfg pile |
publisher |
Czech Technical University, Prague |
publishDate |
2018 |
url |
https://doi.org/10.14311/CEJ.2018.03.0024 https://doaj.org/article/85268746e68747b0985245f288ade415 |
genre |
permafrost |
genre_facet |
permafrost |
op_source |
Civil Engineering Journal, Vol 2018, Iss 3, Pp 291-306 (2018) |
op_relation |
http://civilengineeringjournal.cz/archive/issues/2018/2018_3/3-2018-0024-(291-306)-Final.pdf https://doaj.org/toc/1805-2576 doi:10.14311/CEJ.2018.03.0024 1805-2576 https://doaj.org/article/85268746e68747b0985245f288ade415 |
op_doi |
https://doi.org/10.14311/CEJ.2018.03.0024 |
container_title |
Stavební obzor - Civil Engineering Journal |
container_volume |
27 |
container_issue |
3 |
container_start_page |
291 |
op_container_end_page |
306 |
_version_ |
1775354270806179840 |