Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the gray wolf.

Finite Element Analysis (FEA) is a powerful tool gaining use in studies of biological form and function. This method is particularly conducive to studies of extinct and fossilized organisms, as models can be assigned properties that approximate living tissues. In disciplines where model validation i...

Full description

Bibliographic Details
Published in:PLoS ONE
Main Authors: Zhijie Jack Tseng, Jill L McNitt-Gray, Henryk Flashner, Xiaoming Wang, Reyes Enciso
Format: Article in Journal/Newspaper
Language:English
Published: Public Library of Science (PLoS) 2011
Subjects:
R
Q
Online Access:https://doi.org/10.1371/journal.pone.0019171
https://doaj.org/article/6c0fe617cc4242e1852958ec2a557fc0
id ftdoajarticles:oai:doaj.org/article:6c0fe617cc4242e1852958ec2a557fc0
record_format openpolar
spelling ftdoajarticles:oai:doaj.org/article:6c0fe617cc4242e1852958ec2a557fc0 2023-05-15T15:51:13+02:00 Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the gray wolf. Zhijie Jack Tseng Jill L McNitt-Gray Henryk Flashner Xiaoming Wang Reyes Enciso 2011-01-01T00:00:00Z https://doi.org/10.1371/journal.pone.0019171 https://doaj.org/article/6c0fe617cc4242e1852958ec2a557fc0 EN eng Public Library of Science (PLoS) http://europepmc.org/articles/PMC3084775?pdf=render https://doaj.org/toc/1932-6203 1932-6203 doi:10.1371/journal.pone.0019171 https://doaj.org/article/6c0fe617cc4242e1852958ec2a557fc0 PLoS ONE, Vol 6, Iss 4, p e19171 (2011) Medicine R Science Q article 2011 ftdoajarticles https://doi.org/10.1371/journal.pone.0019171 2022-12-31T13:22:43Z Finite Element Analysis (FEA) is a powerful tool gaining use in studies of biological form and function. This method is particularly conducive to studies of extinct and fossilized organisms, as models can be assigned properties that approximate living tissues. In disciplines where model validation is difficult or impossible, the choice of model parameters and their effects on the results become increasingly important, especially in comparing outputs to infer function. To evaluate the extent to which performance measures are affected by initial model input, we tested the sensitivity of bite force, strain energy, and stress to changes in seven parameters that are required in testing craniodental function with FEA. Simulations were performed on FE models of a Gray Wolf (Canis lupus) mandible. Results showed that unilateral bite force outputs are least affected by the relative ratios of the balancing and working muscles, but only ratios above 0.5 provided balancing-working side joint reaction force relationships that are consistent with experimental data. The constraints modeled at the bite point had the greatest effect on bite force output, but the most appropriate constraint may depend on the study question. Strain energy is least affected by variation in bite point constraint, but larger variations in strain energy values are observed in models with different number of tetrahedral elements, masticatory muscle ratios and muscle subgroups present, and number of material properties. These findings indicate that performance measures are differentially affected by variation in initial model parameters. In the absence of validated input values, FE models can nevertheless provide robust comparisons if these parameters are standardized within a given study to minimize variation that arise during the model-building process. Sensitivity tests incorporated into the study design not only aid in the interpretation of simulation results, but can also provide additional insights on form and function. Article in Journal/Newspaper Canis lupus gray wolf Directory of Open Access Journals: DOAJ Articles PLoS ONE 6 4 e19171
institution Open Polar
collection Directory of Open Access Journals: DOAJ Articles
op_collection_id ftdoajarticles
language English
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Zhijie Jack Tseng
Jill L McNitt-Gray
Henryk Flashner
Xiaoming Wang
Reyes Enciso
Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the gray wolf.
topic_facet Medicine
R
Science
Q
description Finite Element Analysis (FEA) is a powerful tool gaining use in studies of biological form and function. This method is particularly conducive to studies of extinct and fossilized organisms, as models can be assigned properties that approximate living tissues. In disciplines where model validation is difficult or impossible, the choice of model parameters and their effects on the results become increasingly important, especially in comparing outputs to infer function. To evaluate the extent to which performance measures are affected by initial model input, we tested the sensitivity of bite force, strain energy, and stress to changes in seven parameters that are required in testing craniodental function with FEA. Simulations were performed on FE models of a Gray Wolf (Canis lupus) mandible. Results showed that unilateral bite force outputs are least affected by the relative ratios of the balancing and working muscles, but only ratios above 0.5 provided balancing-working side joint reaction force relationships that are consistent with experimental data. The constraints modeled at the bite point had the greatest effect on bite force output, but the most appropriate constraint may depend on the study question. Strain energy is least affected by variation in bite point constraint, but larger variations in strain energy values are observed in models with different number of tetrahedral elements, masticatory muscle ratios and muscle subgroups present, and number of material properties. These findings indicate that performance measures are differentially affected by variation in initial model parameters. In the absence of validated input values, FE models can nevertheless provide robust comparisons if these parameters are standardized within a given study to minimize variation that arise during the model-building process. Sensitivity tests incorporated into the study design not only aid in the interpretation of simulation results, but can also provide additional insights on form and function.
format Article in Journal/Newspaper
author Zhijie Jack Tseng
Jill L McNitt-Gray
Henryk Flashner
Xiaoming Wang
Reyes Enciso
author_facet Zhijie Jack Tseng
Jill L McNitt-Gray
Henryk Flashner
Xiaoming Wang
Reyes Enciso
author_sort Zhijie Jack Tseng
title Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the gray wolf.
title_short Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the gray wolf.
title_full Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the gray wolf.
title_fullStr Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the gray wolf.
title_full_unstemmed Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the gray wolf.
title_sort model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the gray wolf.
publisher Public Library of Science (PLoS)
publishDate 2011
url https://doi.org/10.1371/journal.pone.0019171
https://doaj.org/article/6c0fe617cc4242e1852958ec2a557fc0
genre Canis lupus
gray wolf
genre_facet Canis lupus
gray wolf
op_source PLoS ONE, Vol 6, Iss 4, p e19171 (2011)
op_relation http://europepmc.org/articles/PMC3084775?pdf=render
https://doaj.org/toc/1932-6203
1932-6203
doi:10.1371/journal.pone.0019171
https://doaj.org/article/6c0fe617cc4242e1852958ec2a557fc0
op_doi https://doi.org/10.1371/journal.pone.0019171
container_title PLoS ONE
container_volume 6
container_issue 4
container_start_page e19171
_version_ 1766386324682571776