Comparison of real-time PCR and microscopy for malaria parasite detection in Malawian pregnant women

Abstract Background New diagnostic tools for malaria are required owing to the changing epidemiology of malaria, particularly among pregnant women in sub-Saharan Africa. Real-time PCR assays targeting Plasmodium falciparum lactate dehydrogenase ( pfldh ) gene may facilitate the identification of a h...

Full description

Bibliographic Details
Published in:Malaria Journal
Main Authors: Maleta Kenneth, Mbewe Bernard, Luntamo Mari, Trottman Paul A, Taylor Steve M, Rantala Anne-Maria, Kulmala Teija, Ashorn Per, Meshnick Steven R
Format: Article in Journal/Newspaper
Language:English
Published: BMC 2010
Subjects:
Online Access:https://doi.org/10.1186/1475-2875-9-269
https://doaj.org/article/5dbb0856968144ccad896980af15dd3b
Description
Summary:Abstract Background New diagnostic tools for malaria are required owing to the changing epidemiology of malaria, particularly among pregnant women in sub-Saharan Africa. Real-time PCR assays targeting Plasmodium falciparum lactate dehydrogenase ( pfldh ) gene may facilitate the identification of a high proportion of pregnant women with a P. falciparum parasitaemia below the threshold of microscopy. These molecular methods will enable further studies on the effects of these submicroscopic infections on maternal health and birth outcomes. Methods The pfldh real-time PCR assay and conventional microscopy were compared for the detection of P. falciparum from dried blood spots and blood smears collected from the peripheral blood of 475 Malawian women at delivery. A cycle threshold (Ct) of the real-time PCR was determined optimizing the sensitivity and specificity of the pfldh PCR assay compared to microscopy. A real-time PCR species-specific assay was applied to identify the contribution to malaria infections of three Plasmodium species ( P. falciparum P. ovale and P. malariae ) in 44 discordant smear and pfldh PCR assay results. Results Of the 475 women, P. falciparum was detected in 11 (2.3%) by microscopy and in 51 (10.7%) by real-time PCR; compared to microscopy, the sensitivity of real-time PCR was 90.9% and the specificity 91.2%. If a Ct value of 38 was used as a cut-off, specificity improved to 94.6% with no change in sensitivity. The real-time PCR species-specific assay detected P. falciparum alone in all but four samples: two samples were mixed infections with P. falciparum and P. malariae , one was a pure P. malariae infection and one was a pfldh PCR assay-positive/species-specific assay-negative sample. Of three P. malariae infections detected by microscopy, only one was confirmed by the species-specific assay. Conclusions Although microscopy remains the most appropriate method for clinical malaria diagnosis in field settings, molecular diagnostics such as real-time PCR offer a more reliable means to ...