Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia

Abstract Background Pregnant women frequently show low-density Plasmodium infections that require more sensitive methods for accurate diagnosis and early treatment of malaria. This is particularly relevant in low-malaria transmission areas, where intermittent preventive treatment is not recommended....

Full description

Bibliographic Details
Published in:Malaria Journal
Main Authors: Ana María Vásquez, Lina Zuluaga, Alberto Tobón, Maritza Posada, Gabriel Vélez, Iveth J. González, Ana Campillo, Xavier Ding
Format: Article in Journal/Newspaper
Language:English
Published: BMC 2018
Subjects:
Online Access:https://doi.org/10.1186/s12936-018-2403-5
https://doaj.org/article/13609820da4f4d15afba0892938635ab
id ftdoajarticles:oai:doaj.org/article:13609820da4f4d15afba0892938635ab
record_format openpolar
spelling ftdoajarticles:oai:doaj.org/article:13609820da4f4d15afba0892938635ab 2023-05-15T15:17:34+02:00 Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia Ana María Vásquez Lina Zuluaga Alberto Tobón Maritza Posada Gabriel Vélez Iveth J. González Ana Campillo Xavier Ding 2018-07-01T00:00:00Z https://doi.org/10.1186/s12936-018-2403-5 https://doaj.org/article/13609820da4f4d15afba0892938635ab EN eng BMC http://link.springer.com/article/10.1186/s12936-018-2403-5 https://doaj.org/toc/1475-2875 doi:10.1186/s12936-018-2403-5 1475-2875 https://doaj.org/article/13609820da4f4d15afba0892938635ab Malaria Journal, Vol 17, Iss 1, Pp 1-11 (2018) Malaria in pregnancy Diagnostics Rapid diagnostic test Light microscopy Loop mediated isothermal amplification Polymerase chain reaction Arctic medicine. Tropical medicine RC955-962 Infectious and parasitic diseases RC109-216 article 2018 ftdoajarticles https://doi.org/10.1186/s12936-018-2403-5 2022-12-31T11:57:15Z Abstract Background Pregnant women frequently show low-density Plasmodium infections that require more sensitive methods for accurate diagnosis and early treatment of malaria. This is particularly relevant in low-malaria transmission areas, where intermittent preventive treatment is not recommended. Molecular methods, such as polymerase chain reaction (PCR) are highly sensitive, but require sophisticated equipment and advanced training. Instead, loop mediated isothermal amplification (LAMP) provides an opportunity for molecular detection of malaria infections in remote endemic areas, outside a reference laboratory. The aim of the study is to evaluate the performance of LAMP for the screening of malaria in pregnant women in Colombia. Methods This is a nested prospective study that uses data and samples from a larger cross-sectional project conducted from May 2016 to January 2017 in three Colombian endemic areas (El Bagre, Quibdó, and Tumaco). A total of 531 peripheral and placental samples from pregnant women self-presenting at local hospitals for antenatal care visits, at delivery or seeking medical care for suspected malaria were collected. Samples were analysed for Plasmodium parasites by light microscopy (LM), rapid diagnostic test (RDT) and LAMP. Diagnostic accuracy endpoints (sensitivity, specificity, predictive values, and kappa scores) of LM, RDT and LAMP were compared with nested PCR (nPCR) as the reference standard. Results In peripheral samples, LAMP showed an improved sensitivity (100.0%) when compared with LM 79.5% and RDT 76.9% (p < 0.01), particularly in afebrile women, for which LAMP sensitivity was two-times higher than LM and RDT. Overall agreement among LAMP and nPCR was high (kappa value = 1.0). Specificity was similar in all tests (100%). In placental blood, LAMP evidenced a four-fold improvement in sensitivity (88.9%) when compared with LM and RDT (22.2%), being the only method, together with nPCR, able to detect placental infections in peripheral blood. Conclusions LAMP is a simple, ... Article in Journal/Newspaper Arctic Directory of Open Access Journals: DOAJ Articles Arctic Malaria Journal 17 1
institution Open Polar
collection Directory of Open Access Journals: DOAJ Articles
op_collection_id ftdoajarticles
language English
topic Malaria in pregnancy
Diagnostics
Rapid diagnostic test
Light microscopy
Loop mediated isothermal amplification
Polymerase chain reaction
Arctic medicine. Tropical medicine
RC955-962
Infectious and parasitic diseases
RC109-216
spellingShingle Malaria in pregnancy
Diagnostics
Rapid diagnostic test
Light microscopy
Loop mediated isothermal amplification
Polymerase chain reaction
Arctic medicine. Tropical medicine
RC955-962
Infectious and parasitic diseases
RC109-216
Ana María Vásquez
Lina Zuluaga
Alberto Tobón
Maritza Posada
Gabriel Vélez
Iveth J. González
Ana Campillo
Xavier Ding
Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia
topic_facet Malaria in pregnancy
Diagnostics
Rapid diagnostic test
Light microscopy
Loop mediated isothermal amplification
Polymerase chain reaction
Arctic medicine. Tropical medicine
RC955-962
Infectious and parasitic diseases
RC109-216
description Abstract Background Pregnant women frequently show low-density Plasmodium infections that require more sensitive methods for accurate diagnosis and early treatment of malaria. This is particularly relevant in low-malaria transmission areas, where intermittent preventive treatment is not recommended. Molecular methods, such as polymerase chain reaction (PCR) are highly sensitive, but require sophisticated equipment and advanced training. Instead, loop mediated isothermal amplification (LAMP) provides an opportunity for molecular detection of malaria infections in remote endemic areas, outside a reference laboratory. The aim of the study is to evaluate the performance of LAMP for the screening of malaria in pregnant women in Colombia. Methods This is a nested prospective study that uses data and samples from a larger cross-sectional project conducted from May 2016 to January 2017 in three Colombian endemic areas (El Bagre, Quibdó, and Tumaco). A total of 531 peripheral and placental samples from pregnant women self-presenting at local hospitals for antenatal care visits, at delivery or seeking medical care for suspected malaria were collected. Samples were analysed for Plasmodium parasites by light microscopy (LM), rapid diagnostic test (RDT) and LAMP. Diagnostic accuracy endpoints (sensitivity, specificity, predictive values, and kappa scores) of LM, RDT and LAMP were compared with nested PCR (nPCR) as the reference standard. Results In peripheral samples, LAMP showed an improved sensitivity (100.0%) when compared with LM 79.5% and RDT 76.9% (p < 0.01), particularly in afebrile women, for which LAMP sensitivity was two-times higher than LM and RDT. Overall agreement among LAMP and nPCR was high (kappa value = 1.0). Specificity was similar in all tests (100%). In placental blood, LAMP evidenced a four-fold improvement in sensitivity (88.9%) when compared with LM and RDT (22.2%), being the only method, together with nPCR, able to detect placental infections in peripheral blood. Conclusions LAMP is a simple, ...
format Article in Journal/Newspaper
author Ana María Vásquez
Lina Zuluaga
Alberto Tobón
Maritza Posada
Gabriel Vélez
Iveth J. González
Ana Campillo
Xavier Ding
author_facet Ana María Vásquez
Lina Zuluaga
Alberto Tobón
Maritza Posada
Gabriel Vélez
Iveth J. González
Ana Campillo
Xavier Ding
author_sort Ana María Vásquez
title Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia
title_short Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia
title_full Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia
title_fullStr Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia
title_full_unstemmed Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia
title_sort diagnostic accuracy of loop-mediated isothermal amplification (lamp) for screening malaria in peripheral and placental blood samples from pregnant women in colombia
publisher BMC
publishDate 2018
url https://doi.org/10.1186/s12936-018-2403-5
https://doaj.org/article/13609820da4f4d15afba0892938635ab
geographic Arctic
geographic_facet Arctic
genre Arctic
genre_facet Arctic
op_source Malaria Journal, Vol 17, Iss 1, Pp 1-11 (2018)
op_relation http://link.springer.com/article/10.1186/s12936-018-2403-5
https://doaj.org/toc/1475-2875
doi:10.1186/s12936-018-2403-5
1475-2875
https://doaj.org/article/13609820da4f4d15afba0892938635ab
op_doi https://doi.org/10.1186/s12936-018-2403-5
container_title Malaria Journal
container_volume 17
container_issue 1
_version_ 1766347815220412416