Qualidade do Ar Interno (QAI) em uma estação científica na Antártica: Identificação de fontes de poluição e estratégias de controle

The research stations in Antarctica present real building operation situations, which makes them potential objects for the investigation of Indoor Air Quality (IAQ). In this context, this paper identifies the main air pollution sources based on data previously collected at the Brazilian Comandante F...

Full description

Bibliographic Details
Main Authors: Érica, Érica Coelho Pagel, Engel de Alvarez, Cristina, Neyval, Neyval Costa Reis Júnior
Format: Article in Journal/Newspaper
Language:Portuguese
Published: 2016
Subjects:
Online Access:https://dialnet.unirioja.es/servlet/oaiart?codigo=5567778
id ftdialnet:oai:dialnet.unirioja.es:ART0000998456
record_format openpolar
institution Open Polar
collection Dialnet - Portada de revistas (Universidad de La Rioja)
op_collection_id ftdialnet
language Portuguese
topic Indoor Air Quality
indoor sources
Antarctic buildings
Qualidade do Ar Interno
fontes internas
edificações Antárticas
spellingShingle Indoor Air Quality
indoor sources
Antarctic buildings
Qualidade do Ar Interno
fontes internas
edificações Antárticas
Érica, Érica Coelho Pagel
Engel de Alvarez, Cristina
Neyval, Neyval Costa Reis Júnior
Qualidade do Ar Interno (QAI) em uma estação científica na Antártica: Identificação de fontes de poluição e estratégias de controle
topic_facet Indoor Air Quality
indoor sources
Antarctic buildings
Qualidade do Ar Interno
fontes internas
edificações Antárticas
description The research stations in Antarctica present real building operation situations, which makes them potential objects for the investigation of Indoor Air Quality (IAQ). In this context, this paper identifies the main air pollution sources based on data previously collected at the Brazilian Comandante Ferraz Antarctic Station (EACF) and determines IAQ control strategies for Brazilian Antarctic buildings. These strategies were incorporated into the EACF reconstruction project after a fire in February 2012 destroyed the main section of the station. Among the most important points proposed by the new project in relation to indoor air quality were the implementation of blocks, an efficient air exchange system, and the specification of materials with low Volatile Organic Compound (VOC) emissions. The construction of the building in blocks based on function avoided the crossing of air pollution from service areas to habitable environments. However, due to the confined characteristics of an Antarctic research station, the specification of materials containing adhesives and resins, even those that are certified, is still a concern for human health. As estações cientí cas na Antártica con guram situações reais de funcionamento de um edifício, o que as torna um potencial objeto na investigação da Qualidade do Ar Interno (QAI). Neste contexto, o presente trabalho diagnosticou as principais fontes de contaminação aérea, baseado em dados previamente coletados na Estação Antártica Comandante Ferraz (EACF) e determinou estratégias de controle da QAI para edi cações brasileiras antárticas. Essas estratégias foram incorporadas ao projeto de reconstrução da EACF, necessário após o incêndio em fevereiro de 2012 que destruiu o corpo principal da Estação. Dentre os pontos positivos propostos pelo novo projeto, em relação à qualidade do ar interno, tem-se a implantação por blocos, um sistema de renovação de ar e ciente e a preocupação na especi cação de materiais com baixa emissão de compostos orgânicos voláteis (COV). A setorização ...
format Article in Journal/Newspaper
author Érica, Érica Coelho Pagel
Engel de Alvarez, Cristina
Neyval, Neyval Costa Reis Júnior
author_facet Érica, Érica Coelho Pagel
Engel de Alvarez, Cristina
Neyval, Neyval Costa Reis Júnior
author_sort Érica, Érica Coelho Pagel
title Qualidade do Ar Interno (QAI) em uma estação científica na Antártica: Identificação de fontes de poluição e estratégias de controle
title_short Qualidade do Ar Interno (QAI) em uma estação científica na Antártica: Identificação de fontes de poluição e estratégias de controle
title_full Qualidade do Ar Interno (QAI) em uma estação científica na Antártica: Identificação de fontes de poluição e estratégias de controle
title_fullStr Qualidade do Ar Interno (QAI) em uma estação científica na Antártica: Identificação de fontes de poluição e estratégias de controle
title_full_unstemmed Qualidade do Ar Interno (QAI) em uma estação científica na Antártica: Identificação de fontes de poluição e estratégias de controle
title_sort qualidade do ar interno (qai) em uma estação científica na antártica: identificação de fontes de poluição e estratégias de controle
publishDate 2016
url https://dialnet.unirioja.es/servlet/oaiart?codigo=5567778
long_lat ENVELOPE(-64.117,-64.117,-65.117,-65.117)
ENVELOPE(44.209,44.209,68.045,68.045)
geographic Antarctic
Ferraz
Torna
geographic_facet Antarctic
Ferraz
Torna
genre Antarc*
Antarctic
Antarctica
Antártica
genre_facet Antarc*
Antarctic
Antarctica
Antártica
op_source Hábitat Sustentable, ISSN 0719-0700, Vol. 6, Nº. 1 (Junio), 2016, pags. 60-71
op_relation https://dialnet.unirioja.es/servlet/oaiart?codigo=5567778
(Revista) ISSN 0719-0700
op_rights LICENCIA DE USO: Los documentos a texto completo incluidos en Dialnet son de acceso libre y propiedad de sus autores y/o editores. Por tanto, cualquier acto de reproducción, distribución, comunicación pública y/o transformación total o parcial requiere el consentimiento expreso y escrito de aquéllos. Cualquier enlace al texto completo de estos documentos deberá hacerse a través de la URL oficial de éstos en Dialnet. Más información: https://dialnet.unirioja.es/info/derechosOAI | INTELLECTUAL PROPERTY RIGHTS STATEMENT: Full text documents hosted by Dialnet are protected by copyright and/or related rights. This digital object is accessible without charge, but its use is subject to the licensing conditions set by its authors or editors. Unless expressly stated otherwise in the licensing conditions, you are free to linking, browsing, printing and making a copy for your own personal purposes. All other acts of reproduction and communication to the public are subject to the licensing conditions expressed by editors and authors and require consent from them. Any link to this document should be made using its official URL in Dialnet. More info: https://dialnet.unirioja.es/info/derechosOAI
_version_ 1802651229577281536
spelling ftdialnet:oai:dialnet.unirioja.es:ART0000998456 2024-06-23T07:47:08+00:00 Qualidade do Ar Interno (QAI) em uma estação científica na Antártica: Identificação de fontes de poluição e estratégias de controle Érica, Érica Coelho Pagel Engel de Alvarez, Cristina Neyval, Neyval Costa Reis Júnior 2016 application/pdf https://dialnet.unirioja.es/servlet/oaiart?codigo=5567778 por por https://dialnet.unirioja.es/servlet/oaiart?codigo=5567778 (Revista) ISSN 0719-0700 LICENCIA DE USO: Los documentos a texto completo incluidos en Dialnet son de acceso libre y propiedad de sus autores y/o editores. Por tanto, cualquier acto de reproducción, distribución, comunicación pública y/o transformación total o parcial requiere el consentimiento expreso y escrito de aquéllos. Cualquier enlace al texto completo de estos documentos deberá hacerse a través de la URL oficial de éstos en Dialnet. Más información: https://dialnet.unirioja.es/info/derechosOAI | INTELLECTUAL PROPERTY RIGHTS STATEMENT: Full text documents hosted by Dialnet are protected by copyright and/or related rights. This digital object is accessible without charge, but its use is subject to the licensing conditions set by its authors or editors. Unless expressly stated otherwise in the licensing conditions, you are free to linking, browsing, printing and making a copy for your own personal purposes. All other acts of reproduction and communication to the public are subject to the licensing conditions expressed by editors and authors and require consent from them. Any link to this document should be made using its official URL in Dialnet. More info: https://dialnet.unirioja.es/info/derechosOAI Hábitat Sustentable, ISSN 0719-0700, Vol. 6, Nº. 1 (Junio), 2016, pags. 60-71 Indoor Air Quality indoor sources Antarctic buildings Qualidade do Ar Interno fontes internas edificações Antárticas text (article) 2016 ftdialnet 2024-06-11T14:35:06Z The research stations in Antarctica present real building operation situations, which makes them potential objects for the investigation of Indoor Air Quality (IAQ). In this context, this paper identifies the main air pollution sources based on data previously collected at the Brazilian Comandante Ferraz Antarctic Station (EACF) and determines IAQ control strategies for Brazilian Antarctic buildings. These strategies were incorporated into the EACF reconstruction project after a fire in February 2012 destroyed the main section of the station. Among the most important points proposed by the new project in relation to indoor air quality were the implementation of blocks, an efficient air exchange system, and the specification of materials with low Volatile Organic Compound (VOC) emissions. The construction of the building in blocks based on function avoided the crossing of air pollution from service areas to habitable environments. However, due to the confined characteristics of an Antarctic research station, the specification of materials containing adhesives and resins, even those that are certified, is still a concern for human health. As estações cientí cas na Antártica con guram situações reais de funcionamento de um edifício, o que as torna um potencial objeto na investigação da Qualidade do Ar Interno (QAI). Neste contexto, o presente trabalho diagnosticou as principais fontes de contaminação aérea, baseado em dados previamente coletados na Estação Antártica Comandante Ferraz (EACF) e determinou estratégias de controle da QAI para edi cações brasileiras antárticas. Essas estratégias foram incorporadas ao projeto de reconstrução da EACF, necessário após o incêndio em fevereiro de 2012 que destruiu o corpo principal da Estação. Dentre os pontos positivos propostos pelo novo projeto, em relação à qualidade do ar interno, tem-se a implantação por blocos, um sistema de renovação de ar e ciente e a preocupação na especi cação de materiais com baixa emissão de compostos orgânicos voláteis (COV). A setorização ... Article in Journal/Newspaper Antarc* Antarctic Antarctica Antártica Dialnet - Portada de revistas (Universidad de La Rioja) Antarctic Ferraz ENVELOPE(-64.117,-64.117,-65.117,-65.117) Torna ENVELOPE(44.209,44.209,68.045,68.045)