Porcelain Insulator Performance Under Different Condition Of Installation Around Aligarh

Modern Society is strongly dependent on a reliable power supply. The availability of cheap and reliable supply of electrical energy is an indicator of societal welfare. Uninterrupted reliable operation of a modern power system depends to a great extent on reliable and satisfactory performance of ins...

Full description

Bibliographic Details
Main Authors: Asfar Ali Khan, Ekram Husain
Format: Text
Language:English
Published: Zenodo 2013
Subjects:
Online Access:https://dx.doi.org/10.5281/zenodo.1087339
https://zenodo.org/record/1087339
id ftdatacite:10.5281/zenodo.1087339
record_format openpolar
institution Open Polar
collection DataCite Metadata Store (German National Library of Science and Technology)
op_collection_id ftdatacite
language English
topic Porcelain insulators
Flashover Voltage
pH value
Conductivity
ESDD.
spellingShingle Porcelain insulators
Flashover Voltage
pH value
Conductivity
ESDD.
Asfar Ali Khan
Ekram Husain
Porcelain Insulator Performance Under Different Condition Of Installation Around Aligarh
topic_facet Porcelain insulators
Flashover Voltage
pH value
Conductivity
ESDD.
description Modern Society is strongly dependent on a reliable power supply. The availability of cheap and reliable supply of electrical energy is an indicator of societal welfare. Uninterrupted reliable operation of a modern power system depends to a great extent on reliable and satisfactory performance of insulators under different environmental conditions. This paper reports result of natural pollution tests that have been done at sites around city of Aligarh (India). Flashover voltage per insulation distance (FOVUID) of porcelain disc insulator for different pH values, ESDD has been recorded for proper correlation between electrical and chemical parameters. The pH of the contaminants has been suggested to be an effective pollution severity indicator and may be used as a diagnostic parameter for proper maintenance of porcelain insulators. : {"references": ["", "J.S.T.Looms, \"Insulators for High Voltage\", Peter Peregrinus Ltd.,\nLondon, 1990.", "Mackevich J and Shah,Minesh, \"Polymer Outdoor Insulating Materials\nPart I: Comparison of Porcelain and Polymer Electrical Insulation\",\nIEEE Electrical Insulation Magazine, May/June 1997, Vol13, No3,\npage 5-12.", "Lambeth, P.J, \"Effect of pollution on high voltage outdoor insulators\",\nProceedings of IEE, IEE Reviews, Vol. 118, No.9R, pp.1107-1130,\n1971.", "IEEE Working Group, \"Application of Insulators in a contaminated\nenvironment\", IEEE Transactions on Power Apparatus and Systems,\nVol.PAS-98, No.5, pp.1676-1695, 1979.", "Ely, C.H.A and Lambeth, P.J \" Artificial Pollution Test for High\nVoltage Outdoor Insulators\", Proceedings of IEE, Vol. 111, No. 5,\npp.991-998,1964.", "Asfar A Khan et al, \"A Study of Flashover Voltage of Artificially\nPolluted Porcelain Disc Insulator under Natural Fog Conditions\"\nProceedings of 2008 International conference on condition monitoring\nand diagnosis (CMD2008), Beijing April 2008,, pp 369-371.", "Asfar Ali Khan et al, \" Effect of Contaminant pH and natural fog on\nnaturally polluted porcelain disc insulators in northern region of India\",\n2009 Annual report of IEEE Conference on Electrical Insulation and\nDielectric Phenomena (CEIDP 2009), Virginia USA, 18-21Oct. 2009, pp\n343-347.", "Asfar Ali Khan, \"Condition monitoring of insulators under pollution\"\nPh.D thesis, AMU, Aligarh 2009.", "Asfar A Khan and Ekram Husain, \"Flashover Characteristics of\nPorcelain Insulators near a Coal Fired Thermal Power plant\",\nProceedings of National Conference on Recent Trends in Electrical\nEngineering, LNCT Bhopal, 26-27 March 2010, pp 63-66.\n[10] Indian Standard IS 1876-1963.\n[11] M Ashfaq Ahmad, \"Study of artificially polluted suspension insulators\nunder Natural fog conditions\" M.Sc (Engg) Dissertation 1995.\n[12] McElroy, A.J et al,\"Insulators with contaminated surfaces, Part I: Field\nconditions and their laboratory simulation\" IEEE Transactions on Power\nApparatus and Systems, Vol.PAS-89, No.8, pp.1848-1858, 1970.\n[13] W. A .Chisholm, et al,\" Accurate measurement of low insulator\ncontamination levels\" IEEE Transactions on Power Delivery,\nVol.PWRD-9, No.3, July, 1994, pp.1552-1557.\n[14] M. Sami Ahmad et al, \"Pollution of Shallow Aquifer in Aligarh Muslim\nUniversity Campus, District Aligarh UP\", Proc. All India Seminar on\nGround Water development, Lucknow, February 1988, pp 107-116.\n[15] Sharifa A Qureshi and Shamshad Ahmad, M.Sc (Geology) Project\nreport, AMU, 2009.\n[16] The Hindustan Times, New Delhi Edition, Page 1, 8th ,9th March 2008\n[17] Saqib, M et al, \"Correlation among Pollution Severity Indicators and\nFlashover Voltage on Porcelain Insulator\" International Conference\nTeerthankar Mahaveer University Moradabad India April 2012\n[18] Khan Asfar Ali and M Rihan \"Smart pH sensor for condition monitoring\nof insulators in the smart grid” ISGT (India) 2011, pp 274-277."]}
format Text
author Asfar Ali Khan
Ekram Husain
author_facet Asfar Ali Khan
Ekram Husain
author_sort Asfar Ali Khan
title Porcelain Insulator Performance Under Different Condition Of Installation Around Aligarh
title_short Porcelain Insulator Performance Under Different Condition Of Installation Around Aligarh
title_full Porcelain Insulator Performance Under Different Condition Of Installation Around Aligarh
title_fullStr Porcelain Insulator Performance Under Different Condition Of Installation Around Aligarh
title_full_unstemmed Porcelain Insulator Performance Under Different Condition Of Installation Around Aligarh
title_sort porcelain insulator performance under different condition of installation around aligarh
publisher Zenodo
publishDate 2013
url https://dx.doi.org/10.5281/zenodo.1087339
https://zenodo.org/record/1087339
long_lat ENVELOPE(-63.187,-63.187,-74.152,-74.152)
geographic Indian
McElroy
geographic_facet Indian
McElroy
genre sami
genre_facet sami
op_relation https://dx.doi.org/10.5281/zenodo.1087340
op_rights Open Access
Creative Commons Attribution 4.0
https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
op_rightsnorm CC-BY
op_doi https://doi.org/10.5281/zenodo.1087339
https://doi.org/10.5281/zenodo.1087340
_version_ 1766186853354962944
spelling ftdatacite:10.5281/zenodo.1087339 2023-05-15T18:14:09+02:00 Porcelain Insulator Performance Under Different Condition Of Installation Around Aligarh Asfar Ali Khan Ekram Husain 2013 https://dx.doi.org/10.5281/zenodo.1087339 https://zenodo.org/record/1087339 en eng Zenodo https://dx.doi.org/10.5281/zenodo.1087340 Open Access Creative Commons Attribution 4.0 https://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess CC-BY Porcelain insulators Flashover Voltage pH value Conductivity ESDD. Text Journal article article-journal ScholarlyArticle 2013 ftdatacite https://doi.org/10.5281/zenodo.1087339 https://doi.org/10.5281/zenodo.1087340 2021-11-05T12:55:41Z Modern Society is strongly dependent on a reliable power supply. The availability of cheap and reliable supply of electrical energy is an indicator of societal welfare. Uninterrupted reliable operation of a modern power system depends to a great extent on reliable and satisfactory performance of insulators under different environmental conditions. This paper reports result of natural pollution tests that have been done at sites around city of Aligarh (India). Flashover voltage per insulation distance (FOVUID) of porcelain disc insulator for different pH values, ESDD has been recorded for proper correlation between electrical and chemical parameters. The pH of the contaminants has been suggested to be an effective pollution severity indicator and may be used as a diagnostic parameter for proper maintenance of porcelain insulators. : {"references": ["", "J.S.T.Looms, \"Insulators for High Voltage\", Peter Peregrinus Ltd.,\nLondon, 1990.", "Mackevich J and Shah,Minesh, \"Polymer Outdoor Insulating Materials\nPart I: Comparison of Porcelain and Polymer Electrical Insulation\",\nIEEE Electrical Insulation Magazine, May/June 1997, Vol13, No3,\npage 5-12.", "Lambeth, P.J, \"Effect of pollution on high voltage outdoor insulators\",\nProceedings of IEE, IEE Reviews, Vol. 118, No.9R, pp.1107-1130,\n1971.", "IEEE Working Group, \"Application of Insulators in a contaminated\nenvironment\", IEEE Transactions on Power Apparatus and Systems,\nVol.PAS-98, No.5, pp.1676-1695, 1979.", "Ely, C.H.A and Lambeth, P.J \" Artificial Pollution Test for High\nVoltage Outdoor Insulators\", Proceedings of IEE, Vol. 111, No. 5,\npp.991-998,1964.", "Asfar A Khan et al, \"A Study of Flashover Voltage of Artificially\nPolluted Porcelain Disc Insulator under Natural Fog Conditions\"\nProceedings of 2008 International conference on condition monitoring\nand diagnosis (CMD2008), Beijing April 2008,, pp 369-371.", "Asfar Ali Khan et al, \" Effect of Contaminant pH and natural fog on\nnaturally polluted porcelain disc insulators in northern region of India\",\n2009 Annual report of IEEE Conference on Electrical Insulation and\nDielectric Phenomena (CEIDP 2009), Virginia USA, 18-21Oct. 2009, pp\n343-347.", "Asfar Ali Khan, \"Condition monitoring of insulators under pollution\"\nPh.D thesis, AMU, Aligarh 2009.", "Asfar A Khan and Ekram Husain, \"Flashover Characteristics of\nPorcelain Insulators near a Coal Fired Thermal Power plant\",\nProceedings of National Conference on Recent Trends in Electrical\nEngineering, LNCT Bhopal, 26-27 March 2010, pp 63-66.\n[10] Indian Standard IS 1876-1963.\n[11] M Ashfaq Ahmad, \"Study of artificially polluted suspension insulators\nunder Natural fog conditions\" M.Sc (Engg) Dissertation 1995.\n[12] McElroy, A.J et al,\"Insulators with contaminated surfaces, Part I: Field\nconditions and their laboratory simulation\" IEEE Transactions on Power\nApparatus and Systems, Vol.PAS-89, No.8, pp.1848-1858, 1970.\n[13] W. A .Chisholm, et al,\" Accurate measurement of low insulator\ncontamination levels\" IEEE Transactions on Power Delivery,\nVol.PWRD-9, No.3, July, 1994, pp.1552-1557.\n[14] M. Sami Ahmad et al, \"Pollution of Shallow Aquifer in Aligarh Muslim\nUniversity Campus, District Aligarh UP\", Proc. All India Seminar on\nGround Water development, Lucknow, February 1988, pp 107-116.\n[15] Sharifa A Qureshi and Shamshad Ahmad, M.Sc (Geology) Project\nreport, AMU, 2009.\n[16] The Hindustan Times, New Delhi Edition, Page 1, 8th ,9th March 2008\n[17] Saqib, M et al, \"Correlation among Pollution Severity Indicators and\nFlashover Voltage on Porcelain Insulator\" International Conference\nTeerthankar Mahaveer University Moradabad India April 2012\n[18] Khan Asfar Ali and M Rihan \"Smart pH sensor for condition monitoring\nof insulators in the smart grid” ISGT (India) 2011, pp 274-277."]} Text sami DataCite Metadata Store (German National Library of Science and Technology) Indian McElroy ENVELOPE(-63.187,-63.187,-74.152,-74.152)