Supplementary material: CLT Walls: Assessing the Role of Vapour Barriers and Adaptive Membranes for Enhanced Building Durability ...

Supplementary material for the conference paper "CLT Walls: Assessing the Role of Vapour Barriers and Adaptive Membranes for Enhanced Building Durability" submitted to the International Building Physics Conference IBPC 2024, 25-27 Juni, Toronto, Canada. The supplementary material contains...

Full description

Bibliographic Details
Main Author: Jensen, Nickolaj Feldt
Format: Dataset
Language:unknown
Published: VBN 2024
Subjects:
Online Access:https://dx.doi.org/10.5278/07cb7a00-aa68-41d1-a149-b7218314d057
https://vbn.aau.dk/da/datasets/07cb7a00-aa68-41d1-a149-b7218314d057
_version_ 1830569182682415104
author Jensen, Nickolaj Feldt
author_facet Jensen, Nickolaj Feldt
author_sort Jensen, Nickolaj Feldt
collection DataCite
description Supplementary material for the conference paper "CLT Walls: Assessing the Role of Vapour Barriers and Adaptive Membranes for Enhanced Building Durability" submitted to the International Building Physics Conference IBPC 2024, 25-27 Juni, Toronto, Canada. The supplementary material contains the following: - Drawings of CLT wall models - WUFI Pro model report (describing the model build up and chosen settings) - WUFI Pro simulation results (in Excel format), presented for two sets of models: (1) with initial moisture set to default 80% RH, and (2) with initial moisture at saturation in the outermost 30 mm of the CLT element and remaining parts set to default RH. - VTT mould growth results (in Excel format). - The Danish climate data for Sjælsmark, used for the simulations. (Data for Kiruna, Bergen and Jyväskylä were obtained from the WUFI climate files database and cannot be uploaded as part of this dataset) ...
format Dataset
genre Kiruna
genre_facet Kiruna
geographic Bergen
Canada
Kiruna
geographic_facet Bergen
Canada
Kiruna
id ftdatacite:10.5278/07cb7a00-aa68-41d1-a149-b7218314d057
institution Open Polar
language unknown
op_collection_id ftdatacite
op_doi https://doi.org/10.5278/07cb7a00-aa68-41d1-a149-b7218314d057
op_rights Creative Commons Attribution Share Alike 4.0 International
https://creativecommons.org/licenses/by-sa/4.0/legalcode
cc-by-sa-4.0
publishDate 2024
publisher VBN
record_format openpolar
spelling ftdatacite:10.5278/07cb7a00-aa68-41d1-a149-b7218314d057 2025-04-27T14:32:17+00:00 Supplementary material: CLT Walls: Assessing the Role of Vapour Barriers and Adaptive Membranes for Enhanced Building Durability ... Jensen, Nickolaj Feldt 2024 application/zip https://dx.doi.org/10.5278/07cb7a00-aa68-41d1-a149-b7218314d057 https://vbn.aau.dk/da/datasets/07cb7a00-aa68-41d1-a149-b7218314d057 unknown VBN Creative Commons Attribution Share Alike 4.0 International https://creativecommons.org/licenses/by-sa/4.0/legalcode cc-by-sa-4.0 Cross Laminated Timber Membrane placement Rain exposure Mould growth risk Vapour barrier Moisture adaptive membrane dataset Dataset 2024 ftdatacite https://doi.org/10.5278/07cb7a00-aa68-41d1-a149-b7218314d057 2025-04-02T15:09:13Z Supplementary material for the conference paper "CLT Walls: Assessing the Role of Vapour Barriers and Adaptive Membranes for Enhanced Building Durability" submitted to the International Building Physics Conference IBPC 2024, 25-27 Juni, Toronto, Canada. The supplementary material contains the following: - Drawings of CLT wall models - WUFI Pro model report (describing the model build up and chosen settings) - WUFI Pro simulation results (in Excel format), presented for two sets of models: (1) with initial moisture set to default 80% RH, and (2) with initial moisture at saturation in the outermost 30 mm of the CLT element and remaining parts set to default RH. - VTT mould growth results (in Excel format). - The Danish climate data for Sjælsmark, used for the simulations. (Data for Kiruna, Bergen and Jyväskylä were obtained from the WUFI climate files database and cannot be uploaded as part of this dataset) ... Dataset Kiruna DataCite Bergen Canada Kiruna
spellingShingle Cross Laminated Timber
Membrane placement
Rain exposure
Mould growth risk
Vapour barrier
Moisture adaptive membrane
Jensen, Nickolaj Feldt
Supplementary material: CLT Walls: Assessing the Role of Vapour Barriers and Adaptive Membranes for Enhanced Building Durability ...
title Supplementary material: CLT Walls: Assessing the Role of Vapour Barriers and Adaptive Membranes for Enhanced Building Durability ...
title_full Supplementary material: CLT Walls: Assessing the Role of Vapour Barriers and Adaptive Membranes for Enhanced Building Durability ...
title_fullStr Supplementary material: CLT Walls: Assessing the Role of Vapour Barriers and Adaptive Membranes for Enhanced Building Durability ...
title_full_unstemmed Supplementary material: CLT Walls: Assessing the Role of Vapour Barriers and Adaptive Membranes for Enhanced Building Durability ...
title_short Supplementary material: CLT Walls: Assessing the Role of Vapour Barriers and Adaptive Membranes for Enhanced Building Durability ...
title_sort supplementary material: clt walls: assessing the role of vapour barriers and adaptive membranes for enhanced building durability ...
topic Cross Laminated Timber
Membrane placement
Rain exposure
Mould growth risk
Vapour barrier
Moisture adaptive membrane
topic_facet Cross Laminated Timber
Membrane placement
Rain exposure
Mould growth risk
Vapour barrier
Moisture adaptive membrane
url https://dx.doi.org/10.5278/07cb7a00-aa68-41d1-a149-b7218314d057
https://vbn.aau.dk/da/datasets/07cb7a00-aa68-41d1-a149-b7218314d057