Technical and procedural comparison of two different cryoballoon ablation systems in patients with atrial fibrillation.

PURPOSE The aim was to report procedural and technical differences of a novel cryoballoon (NCB) ablation catheter for pulmonary vein isolation (PVI) compared to the standard cryoballoon (SCB) catheter. METHODS Consecutive patients with atrial fibrillation (AF) undergoing PVI using the NCB and the SC...

Full description

Bibliographic Details
Main Authors: Knecht, Sven, Sticherling, Christian, Roten, Laurent, Badertscher, Patrick, Chollet, Laurève, Küffer, Thomas, Spies, Florian, Madaffari, Antonio, Mühl, Aline, Baldinger, Samuel H., Servatius, Helge, Osswald, Stefan, Reichlin, Tobias, Kühne, Michael
Format: Article in Journal/Newspaper
Language:unknown
Published: Springer 2021
Subjects:
Online Access:https://dx.doi.org/10.48350/163325
https://boris.unibe.ch/163325/
id ftdatacite:10.48350/163325
record_format openpolar
spelling ftdatacite:10.48350/163325 2023-05-15T16:38:20+02:00 Technical and procedural comparison of two different cryoballoon ablation systems in patients with atrial fibrillation. Knecht, Sven Sticherling, Christian Roten, Laurent Badertscher, Patrick Chollet, Laurève Küffer, Thomas Spies, Florian Madaffari, Antonio Mühl, Aline Baldinger, Samuel H. Servatius, Helge Osswald, Stefan Reichlin, Tobias Kühne, Michael 2021 https://dx.doi.org/10.48350/163325 https://boris.unibe.ch/163325/ unknown Springer https://dx.doi.org/10.1007/s10840-021-01035-6 open access Creative Commons Attribution 4.0 International https://creativecommons.org/licenses/by/4.0/legalcode cc-by-4.0 http://purl.org/coar/access_right/c_abf2 CC-BY 610 Medicine & health ScholarlyArticle article-journal Text journal article 2021 ftdatacite https://doi.org/10.48350/163325 https://doi.org/10.1007/s10840-021-01035-6 2022-02-09T13:02:52Z PURPOSE The aim was to report procedural and technical differences of a novel cryoballoon (NCB) ablation catheter for pulmonary vein isolation (PVI) compared to the standard cryoballoon (SCB) catheter. METHODS Consecutive patients with atrial fibrillation (AF) undergoing PVI using the NCB and the SCB were included. Procedural parameters, technical differences, acute efficacy, and safety are reported. RESULTS Eighty patients (age 66 ± 10 years, ejection fraction 57 ± 10%, left atrial volume index 40 ± 6 ml/m2) were studied. With the NCB, 156 of 158 PVs (99%) were isolated compared to isolation of 159 of 159 PVs (100%) with the SCB. The median number of freezes in the NCB and the SCB group was 6 (IQR 5-8) and 5 (IQR 4-7), respectively (p = 0.051), with 73% and 71% of the PVs isolated with a single freeze, respectively. Nadir temperature and temperature at isolation were - 59 ± 6 °C and - 45 ± 17 °C in the NCB group and - 46 ± 7 °C and - 32 ± 23 °C in the SCB group, respectively (both p < 0.001) with no difference in time to isolation (TTI). Procedural differences were observed for the total procedure time (84 ± 29 min in the NCB group and 65 ± 17 min in the SCB group, p = 0.003). There was a peri-procedural stroke in one patient in the NCB group. Differences in catheter design were observed that may account for the differences in temperature recordings and ice cap formation. CONCLUSIONS Acute efficacy and TTI were similar with the NCB compared to the SCB. Measured temperatures were lower with the NCB, most likely due to differences in catheter design. Article in Journal/Newspaper Ice cap DataCite Metadata Store (German National Library of Science and Technology)
institution Open Polar
collection DataCite Metadata Store (German National Library of Science and Technology)
op_collection_id ftdatacite
language unknown
topic 610 Medicine & health
spellingShingle 610 Medicine & health
Knecht, Sven
Sticherling, Christian
Roten, Laurent
Badertscher, Patrick
Chollet, Laurève
Küffer, Thomas
Spies, Florian
Madaffari, Antonio
Mühl, Aline
Baldinger, Samuel H.
Servatius, Helge
Osswald, Stefan
Reichlin, Tobias
Kühne, Michael
Technical and procedural comparison of two different cryoballoon ablation systems in patients with atrial fibrillation.
topic_facet 610 Medicine & health
description PURPOSE The aim was to report procedural and technical differences of a novel cryoballoon (NCB) ablation catheter for pulmonary vein isolation (PVI) compared to the standard cryoballoon (SCB) catheter. METHODS Consecutive patients with atrial fibrillation (AF) undergoing PVI using the NCB and the SCB were included. Procedural parameters, technical differences, acute efficacy, and safety are reported. RESULTS Eighty patients (age 66 ± 10 years, ejection fraction 57 ± 10%, left atrial volume index 40 ± 6 ml/m2) were studied. With the NCB, 156 of 158 PVs (99%) were isolated compared to isolation of 159 of 159 PVs (100%) with the SCB. The median number of freezes in the NCB and the SCB group was 6 (IQR 5-8) and 5 (IQR 4-7), respectively (p = 0.051), with 73% and 71% of the PVs isolated with a single freeze, respectively. Nadir temperature and temperature at isolation were - 59 ± 6 °C and - 45 ± 17 °C in the NCB group and - 46 ± 7 °C and - 32 ± 23 °C in the SCB group, respectively (both p < 0.001) with no difference in time to isolation (TTI). Procedural differences were observed for the total procedure time (84 ± 29 min in the NCB group and 65 ± 17 min in the SCB group, p = 0.003). There was a peri-procedural stroke in one patient in the NCB group. Differences in catheter design were observed that may account for the differences in temperature recordings and ice cap formation. CONCLUSIONS Acute efficacy and TTI were similar with the NCB compared to the SCB. Measured temperatures were lower with the NCB, most likely due to differences in catheter design.
format Article in Journal/Newspaper
author Knecht, Sven
Sticherling, Christian
Roten, Laurent
Badertscher, Patrick
Chollet, Laurève
Küffer, Thomas
Spies, Florian
Madaffari, Antonio
Mühl, Aline
Baldinger, Samuel H.
Servatius, Helge
Osswald, Stefan
Reichlin, Tobias
Kühne, Michael
author_facet Knecht, Sven
Sticherling, Christian
Roten, Laurent
Badertscher, Patrick
Chollet, Laurève
Küffer, Thomas
Spies, Florian
Madaffari, Antonio
Mühl, Aline
Baldinger, Samuel H.
Servatius, Helge
Osswald, Stefan
Reichlin, Tobias
Kühne, Michael
author_sort Knecht, Sven
title Technical and procedural comparison of two different cryoballoon ablation systems in patients with atrial fibrillation.
title_short Technical and procedural comparison of two different cryoballoon ablation systems in patients with atrial fibrillation.
title_full Technical and procedural comparison of two different cryoballoon ablation systems in patients with atrial fibrillation.
title_fullStr Technical and procedural comparison of two different cryoballoon ablation systems in patients with atrial fibrillation.
title_full_unstemmed Technical and procedural comparison of two different cryoballoon ablation systems in patients with atrial fibrillation.
title_sort technical and procedural comparison of two different cryoballoon ablation systems in patients with atrial fibrillation.
publisher Springer
publishDate 2021
url https://dx.doi.org/10.48350/163325
https://boris.unibe.ch/163325/
genre Ice cap
genre_facet Ice cap
op_relation https://dx.doi.org/10.1007/s10840-021-01035-6
op_rights open access
Creative Commons Attribution 4.0 International
https://creativecommons.org/licenses/by/4.0/legalcode
cc-by-4.0
http://purl.org/coar/access_right/c_abf2
op_rightsnorm CC-BY
op_doi https://doi.org/10.48350/163325
https://doi.org/10.1007/s10840-021-01035-6
_version_ 1766028608634093568