GNWT - Great Slave Lake Water Quality Monitoring Program ...

The Great Slave Water Quality Monitoring Program is one component of the proposed Great Slave Lake Research and Monitoring Program which is in development with water partners to: coordinate long-term collection of baseline water quality across the lake; assess trends in water quality and quantity; c...

Full description

Bibliographic Details
Main Author: GNWT ECC Water Monitoring and Stewardship Division
Format: Dataset
Language:English
Published: DataStream 2024
Subjects:
Online Access:https://dx.doi.org/10.25976/3ogv-7n39
https://datastream.org/dataset/c0514cb5-a326-4183-90c0-7293574ee6bd
id ftdatacite:10.25976/3ogv-7n39
record_format openpolar
spelling ftdatacite:10.25976/3ogv-7n39 2024-06-09T07:46:12+00:00 GNWT - Great Slave Lake Water Quality Monitoring Program ... GNWT ECC Water Monitoring and Stewardship Division 2024 https://dx.doi.org/10.25976/3ogv-7n39 https://datastream.org/dataset/c0514cb5-a326-4183-90c0-7293574ee6bd en eng DataStream Dataset dataset 2024 ftdatacite https://doi.org/10.25976/3ogv-7n39 2024-05-13T12:32:31Z The Great Slave Water Quality Monitoring Program is one component of the proposed Great Slave Lake Research and Monitoring Program which is in development with water partners to: coordinate long-term collection of baseline water quality across the lake; assess trends in water quality and quantity; carry out vulnerability assessments; better understand natural variability and changes being observed in the watershed; and to create long term capacity building research and monitoring partnerships. ... : Water samples are collected 2-5 samples per year depending on the location of the sample site. Surface water grab samples are collected at ~10 cm – 50 cm beneath the surface into clean sample bottles. Discrete depth samples are collected at some sites, using a Kemmerer water sampler attached to a pre-measured line using a weighted messenger. Field measurements are also taken at site using YSI EXO 2 Sondes. A suite of water samples consists of ~3 L total of water collected into nine clean sample bottles separated by analysis type. All clean sample bottles are triple rinsed in the field with the sample water before filling. Most parameters are collected into PET bottles while trace mercury samples are collected into duplicate clean borosilicate vials using the “clean hands” and “dirty hands” protocol and additionally stored inside a double layer of PE bags. Total metals are preserved in the field to pH < 2 using HNO₃. QA/QC samples include field duplicates in addition to field and travel blanks. After ... Dataset Great Slave Lake DataCite Metadata Store (German National Library of Science and Technology) Great Slave Lake ENVELOPE(-114.001,-114.001,61.500,61.500)
institution Open Polar
collection DataCite Metadata Store (German National Library of Science and Technology)
op_collection_id ftdatacite
language English
description The Great Slave Water Quality Monitoring Program is one component of the proposed Great Slave Lake Research and Monitoring Program which is in development with water partners to: coordinate long-term collection of baseline water quality across the lake; assess trends in water quality and quantity; carry out vulnerability assessments; better understand natural variability and changes being observed in the watershed; and to create long term capacity building research and monitoring partnerships. ... : Water samples are collected 2-5 samples per year depending on the location of the sample site. Surface water grab samples are collected at ~10 cm – 50 cm beneath the surface into clean sample bottles. Discrete depth samples are collected at some sites, using a Kemmerer water sampler attached to a pre-measured line using a weighted messenger. Field measurements are also taken at site using YSI EXO 2 Sondes. A suite of water samples consists of ~3 L total of water collected into nine clean sample bottles separated by analysis type. All clean sample bottles are triple rinsed in the field with the sample water before filling. Most parameters are collected into PET bottles while trace mercury samples are collected into duplicate clean borosilicate vials using the “clean hands” and “dirty hands” protocol and additionally stored inside a double layer of PE bags. Total metals are preserved in the field to pH < 2 using HNO₃. QA/QC samples include field duplicates in addition to field and travel blanks. After ...
format Dataset
author GNWT ECC Water Monitoring and Stewardship Division
spellingShingle GNWT ECC Water Monitoring and Stewardship Division
GNWT - Great Slave Lake Water Quality Monitoring Program ...
author_facet GNWT ECC Water Monitoring and Stewardship Division
author_sort GNWT ECC Water Monitoring and Stewardship Division
title GNWT - Great Slave Lake Water Quality Monitoring Program ...
title_short GNWT - Great Slave Lake Water Quality Monitoring Program ...
title_full GNWT - Great Slave Lake Water Quality Monitoring Program ...
title_fullStr GNWT - Great Slave Lake Water Quality Monitoring Program ...
title_full_unstemmed GNWT - Great Slave Lake Water Quality Monitoring Program ...
title_sort gnwt - great slave lake water quality monitoring program ...
publisher DataStream
publishDate 2024
url https://dx.doi.org/10.25976/3ogv-7n39
https://datastream.org/dataset/c0514cb5-a326-4183-90c0-7293574ee6bd
long_lat ENVELOPE(-114.001,-114.001,61.500,61.500)
geographic Great Slave Lake
geographic_facet Great Slave Lake
genre Great Slave Lake
genre_facet Great Slave Lake
op_doi https://doi.org/10.25976/3ogv-7n39
_version_ 1801375958153822208