Water Table Depth (WTD) NIMS grid Atqasuk, Alaska 2011

Water table depth (WTD) measurements were taken along the Networked Info-mechanical Systems (NIMS) grid in Atqasuk, Alaska during the summer of 2011. The NIMS grid is situated about 50 meters to the south of the The International Tundra Experiment (ITEX) dry site. If a uniform representation of the...

Full description

Bibliographic Details
Main Author: Vargas, Sergio
Format: Dataset
Language:English
Published: Arctic Data Center 2011
Subjects:
Online Access:https://dx.doi.org/10.18739/a2m33x
https://arcticdata.io/catalog/view/doi:10.18739/A2M33X
id ftdatacite:10.18739/a2m33x
record_format openpolar
spelling ftdatacite:10.18739/a2m33x 2023-05-15T17:58:10+02:00 Water Table Depth (WTD) NIMS grid Atqasuk, Alaska 2011 Vargas, Sergio 2011 text/xml https://dx.doi.org/10.18739/a2m33x https://arcticdata.io/catalog/view/doi:10.18739/A2M33X en eng Arctic Data Center EARTH SCIENCE > LAND SURFACE > SOILS > SOIL MOISTURE/WATER CONTENT IN SITU/LABORATORY INSTRUMENTS > PROBES > PROBES FIELD SURVEY TRANSECT 30 METERS TO 100 METERS MONTHLY TO ANNUAL environment dataset Dataset 2011 ftdatacite https://doi.org/10.18739/a2m33x 2021-11-05T12:55:41Z Water table depth (WTD) measurements were taken along the Networked Info-mechanical Systems (NIMS) grid in Atqasuk, Alaska during the summer of 2011. The NIMS grid is situated about 50 meters to the south of the The International Tundra Experiment (ITEX) dry site. If a uniform representation of the water table within each plot was visible, then a WTD tube was placed there to measure the change in water table throughout the season. For instance if the plot was half saturated and half dry, then that plot was skipped and no tube was placed there. The exact location of WTD tubes are as follows: Between meters 0-1, 3-4, 5-6, 7-8, 9-10, 11-12, 13-14, 15-16, 17-18, 19-20, 21-22, 23-24, 25-26, 32-33, 34-35, 36-37, 38-39, 40-41, 42-43, 44-45, 46-47 & 48-49. A total of 22 WTD tubes were installed into the NIMS grid in Atqasuk. Measurements were made every few days during the summer snow free period between mid June and mid August. WTD was calculated as the difference between the depth (cm) of the water table above or below the measuring tube (- Values = water above tube, + Values= water level below the height of the tube) and the height of the top of the measuring tube above the ground level. Measurements were not made (NA in data sheet) if there was persistent snow cover, interference or disturbance from other experimental infrastructure, or if water table depth tubes were dry to the upper surface of the permafrost. Dataset permafrost Tundra Alaska DataCite Metadata Store (German National Library of Science and Technology)
institution Open Polar
collection DataCite Metadata Store (German National Library of Science and Technology)
op_collection_id ftdatacite
language English
topic EARTH SCIENCE > LAND SURFACE > SOILS > SOIL MOISTURE/WATER CONTENT
IN SITU/LABORATORY INSTRUMENTS > PROBES > PROBES
FIELD SURVEY
TRANSECT
30 METERS TO 100 METERS
MONTHLY TO ANNUAL
environment
spellingShingle EARTH SCIENCE > LAND SURFACE > SOILS > SOIL MOISTURE/WATER CONTENT
IN SITU/LABORATORY INSTRUMENTS > PROBES > PROBES
FIELD SURVEY
TRANSECT
30 METERS TO 100 METERS
MONTHLY TO ANNUAL
environment
Vargas, Sergio
Water Table Depth (WTD) NIMS grid Atqasuk, Alaska 2011
topic_facet EARTH SCIENCE > LAND SURFACE > SOILS > SOIL MOISTURE/WATER CONTENT
IN SITU/LABORATORY INSTRUMENTS > PROBES > PROBES
FIELD SURVEY
TRANSECT
30 METERS TO 100 METERS
MONTHLY TO ANNUAL
environment
description Water table depth (WTD) measurements were taken along the Networked Info-mechanical Systems (NIMS) grid in Atqasuk, Alaska during the summer of 2011. The NIMS grid is situated about 50 meters to the south of the The International Tundra Experiment (ITEX) dry site. If a uniform representation of the water table within each plot was visible, then a WTD tube was placed there to measure the change in water table throughout the season. For instance if the plot was half saturated and half dry, then that plot was skipped and no tube was placed there. The exact location of WTD tubes are as follows: Between meters 0-1, 3-4, 5-6, 7-8, 9-10, 11-12, 13-14, 15-16, 17-18, 19-20, 21-22, 23-24, 25-26, 32-33, 34-35, 36-37, 38-39, 40-41, 42-43, 44-45, 46-47 & 48-49. A total of 22 WTD tubes were installed into the NIMS grid in Atqasuk. Measurements were made every few days during the summer snow free period between mid June and mid August. WTD was calculated as the difference between the depth (cm) of the water table above or below the measuring tube (- Values = water above tube, + Values= water level below the height of the tube) and the height of the top of the measuring tube above the ground level. Measurements were not made (NA in data sheet) if there was persistent snow cover, interference or disturbance from other experimental infrastructure, or if water table depth tubes were dry to the upper surface of the permafrost.
format Dataset
author Vargas, Sergio
author_facet Vargas, Sergio
author_sort Vargas, Sergio
title Water Table Depth (WTD) NIMS grid Atqasuk, Alaska 2011
title_short Water Table Depth (WTD) NIMS grid Atqasuk, Alaska 2011
title_full Water Table Depth (WTD) NIMS grid Atqasuk, Alaska 2011
title_fullStr Water Table Depth (WTD) NIMS grid Atqasuk, Alaska 2011
title_full_unstemmed Water Table Depth (WTD) NIMS grid Atqasuk, Alaska 2011
title_sort water table depth (wtd) nims grid atqasuk, alaska 2011
publisher Arctic Data Center
publishDate 2011
url https://dx.doi.org/10.18739/a2m33x
https://arcticdata.io/catalog/view/doi:10.18739/A2M33X
genre permafrost
Tundra
Alaska
genre_facet permafrost
Tundra
Alaska
op_doi https://doi.org/10.18739/a2m33x
_version_ 1766166725655527424