Integrated water vapor of HATPRO microwave radiometer at AWIPEV, Ny-Ålesund (2019) ...

The microwave radiometer HATPRO has seven K band (22.235-31.4 GHz) channels that are sensitive to the path integrated amount of cloud liquid water (clwvi) and the path integrated amount of water vapor (precipitable water, prw). These files contain prw as a function of measurement time, elevation and...

Full description

Bibliographic Details
Main Authors: Ebell, Kerstin, Ritter, Christoph
Format: Dataset
Language:English
Published: PANGAEA 2022
Subjects:
Online Access:https://dx.doi.org/10.1594/pangaea.943120
https://doi.pangaea.de/10.1594/PANGAEA.943120
id ftdatacite:10.1594/pangaea.943120
record_format openpolar
spelling ftdatacite:10.1594/pangaea.943120 2023-10-01T03:54:02+02:00 Integrated water vapor of HATPRO microwave radiometer at AWIPEV, Ny-Ålesund (2019) ... Ebell, Kerstin Ritter, Christoph 2022 text/tab-separated-values https://dx.doi.org/10.1594/pangaea.943120 https://doi.pangaea.de/10.1594/PANGAEA.943120 en eng PANGAEA https://dx.doi.org/10.1594/pangaea.943004 https://dx.doi.org/10.1029/2002rs002654 https://dx.doi.org/10.5194/acp-19-4105-2019 Creative Commons Attribution 4.0 International https://creativecommons.org/licenses/by/4.0/legalcode cc-by-4.0 integrated water vapor microwave radiometer precipitable water DATE/TIME Binary Object Media Type Binary Object File Size Binary Object Research station AWIPEV_based AWIPEV Arctic Amplification AC3 Dataset dataset 2022 ftdatacite https://doi.org/10.1594/pangaea.94312010.1594/pangaea.94300410.1029/2002rs00265410.5194/acp-19-4105-2019 2023-09-04T14:52:34Z The microwave radiometer HATPRO has seven K band (22.235-31.4 GHz) channels that are sensitive to the path integrated amount of cloud liquid water (clwvi) and the path integrated amount of water vapor (precipitable water, prw). These files contain prw as a function of measurement time, elevation and azimuth angle observing direction. prw is based on multi-variate regression retrievals (see also Löhnert and Crewell, 2003; doi:10.1029/2002RS002654; Nomokonova et al, 2019; doi:10.5194/acp-19-4105-2019). Provided uncertainties describe the expected standard error of prw. Note, that prw values are given for all available times so that it is up to the user to decide whether or not to use the values if quality flags are set. Additionally included are temperature, pressure and humidity at the instrument location as well quality flags characterizing the instrument and retrieval performance. ... Dataset Arctic Ny Ålesund Ny-Ålesund DataCite Metadata Store (German National Library of Science and Technology) Arctic Ny-Ålesund
institution Open Polar
collection DataCite Metadata Store (German National Library of Science and Technology)
op_collection_id ftdatacite
language English
topic integrated water vapor
microwave radiometer
precipitable water
DATE/TIME
Binary Object Media Type
Binary Object File Size
Binary Object
Research station
AWIPEV_based
AWIPEV
Arctic Amplification AC3
spellingShingle integrated water vapor
microwave radiometer
precipitable water
DATE/TIME
Binary Object Media Type
Binary Object File Size
Binary Object
Research station
AWIPEV_based
AWIPEV
Arctic Amplification AC3
Ebell, Kerstin
Ritter, Christoph
Integrated water vapor of HATPRO microwave radiometer at AWIPEV, Ny-Ålesund (2019) ...
topic_facet integrated water vapor
microwave radiometer
precipitable water
DATE/TIME
Binary Object Media Type
Binary Object File Size
Binary Object
Research station
AWIPEV_based
AWIPEV
Arctic Amplification AC3
description The microwave radiometer HATPRO has seven K band (22.235-31.4 GHz) channels that are sensitive to the path integrated amount of cloud liquid water (clwvi) and the path integrated amount of water vapor (precipitable water, prw). These files contain prw as a function of measurement time, elevation and azimuth angle observing direction. prw is based on multi-variate regression retrievals (see also Löhnert and Crewell, 2003; doi:10.1029/2002RS002654; Nomokonova et al, 2019; doi:10.5194/acp-19-4105-2019). Provided uncertainties describe the expected standard error of prw. Note, that prw values are given for all available times so that it is up to the user to decide whether or not to use the values if quality flags are set. Additionally included are temperature, pressure and humidity at the instrument location as well quality flags characterizing the instrument and retrieval performance. ...
format Dataset
author Ebell, Kerstin
Ritter, Christoph
author_facet Ebell, Kerstin
Ritter, Christoph
author_sort Ebell, Kerstin
title Integrated water vapor of HATPRO microwave radiometer at AWIPEV, Ny-Ålesund (2019) ...
title_short Integrated water vapor of HATPRO microwave radiometer at AWIPEV, Ny-Ålesund (2019) ...
title_full Integrated water vapor of HATPRO microwave radiometer at AWIPEV, Ny-Ålesund (2019) ...
title_fullStr Integrated water vapor of HATPRO microwave radiometer at AWIPEV, Ny-Ålesund (2019) ...
title_full_unstemmed Integrated water vapor of HATPRO microwave radiometer at AWIPEV, Ny-Ålesund (2019) ...
title_sort integrated water vapor of hatpro microwave radiometer at awipev, ny-ålesund (2019) ...
publisher PANGAEA
publishDate 2022
url https://dx.doi.org/10.1594/pangaea.943120
https://doi.pangaea.de/10.1594/PANGAEA.943120
geographic Arctic
Ny-Ålesund
geographic_facet Arctic
Ny-Ålesund
genre Arctic
Ny Ålesund
Ny-Ålesund
genre_facet Arctic
Ny Ålesund
Ny-Ålesund
op_relation https://dx.doi.org/10.1594/pangaea.943004
https://dx.doi.org/10.1029/2002rs002654
https://dx.doi.org/10.5194/acp-19-4105-2019
op_rights Creative Commons Attribution 4.0 International
https://creativecommons.org/licenses/by/4.0/legalcode
cc-by-4.0
op_doi https://doi.org/10.1594/pangaea.94312010.1594/pangaea.94300410.1029/2002rs00265410.5194/acp-19-4105-2019
_version_ 1778521258625859584