Electrical conductivity measurements (ECM) from the GRIP ice core, central Greenland ...

ECM data from the GRIP core obtained with the technique described by Hammer (1980). People involved in the measurements include Henrik B. Clausen, Dorthe Dahl-Jensen, Christine Hvidberg, Niels Gundestrup, Steffen B. Hansen, P. M. Kristinsdottir, Jakob Schwander, and J.P. Steffensen. Data were record...

Full description

Bibliographic Details
Main Authors: Rasmussen, Sune Olander, Hansen, Steffen Bo, Hvidberg, Christine Schøtt, Dahl-Jensen, Dorthe, Steffensen, Jørgen Peder
Format: Dataset
Language:English
Published: PANGAEA 2022
Subjects:
Online Access:https://dx.doi.org/10.1594/pangaea.942944
https://doi.pangaea.de/10.1594/PANGAEA.942944
id ftdatacite:10.1594/pangaea.942944
record_format openpolar
spelling ftdatacite:10.1594/pangaea.942944 2024-04-28T08:21:22+00:00 Electrical conductivity measurements (ECM) from the GRIP ice core, central Greenland ... Rasmussen, Sune Olander Hansen, Steffen Bo Hvidberg, Christine Schøtt Dahl-Jensen, Dorthe Steffensen, Jørgen Peder 2022 text/tab-separated-values https://dx.doi.org/10.1594/pangaea.942944 https://doi.pangaea.de/10.1594/PANGAEA.942944 en eng PANGAEA https://dx.doi.org/10.5194/essd-15-3351-2023 https://dx.doi.org/10.3189/s0022143000015227 Creative Commons Attribution 4.0 International https://creativecommons.org/licenses/by/4.0/legalcode cc-by-4.0 DEPTH, ice/snow Hydrogen ion concentration ISTUK electromechanical drill GRIP Sampling/drilling ice dataset Dataset 2022 ftdatacite https://doi.org/10.1594/pangaea.94294410.5194/essd-15-3351-202310.3189/s0022143000015227 2024-04-02T11:42:33Z ECM data from the GRIP core obtained with the technique described by Hammer (1980). People involved in the measurements include Henrik B. Clausen, Dorthe Dahl-Jensen, Christine Hvidberg, Niels Gundestrup, Steffen B. Hansen, P. M. Kristinsdottir, Jakob Schwander, and J.P. Steffensen. Data were recorded in parallel on paper in high resolution and digitally in 1 cm resolution. The main core was drilled during the GRIP project in 1989-1992 at the Summit of the Greenland ice sheet. The length is 3025 m. Present-day accumulation 0.23 m ice/yr. Data from the top 101.3 m comes from the S3 shallow core, but the two data sets have been fully integrated on a common depth scale. The data are given as H+ ion concentration versus depth (measured from the undisturbed surface in 1989), but the absolute calibration (H+ = 0.045 I^1.73) must be considered tentative. For more information on the measurements and calibration, see Hammer 1980 and Clausen et al. (1995). Please cite the Hammer (1980), Clausen et al. (1995), and ... Dataset Greenland GRIP ice core Ice Sheet DataCite Metadata Store (German National Library of Science and Technology)
institution Open Polar
collection DataCite Metadata Store (German National Library of Science and Technology)
op_collection_id ftdatacite
language English
topic DEPTH, ice/snow
Hydrogen ion concentration
ISTUK electromechanical drill
GRIP
Sampling/drilling ice
spellingShingle DEPTH, ice/snow
Hydrogen ion concentration
ISTUK electromechanical drill
GRIP
Sampling/drilling ice
Rasmussen, Sune Olander
Hansen, Steffen Bo
Hvidberg, Christine Schøtt
Dahl-Jensen, Dorthe
Steffensen, Jørgen Peder
Electrical conductivity measurements (ECM) from the GRIP ice core, central Greenland ...
topic_facet DEPTH, ice/snow
Hydrogen ion concentration
ISTUK electromechanical drill
GRIP
Sampling/drilling ice
description ECM data from the GRIP core obtained with the technique described by Hammer (1980). People involved in the measurements include Henrik B. Clausen, Dorthe Dahl-Jensen, Christine Hvidberg, Niels Gundestrup, Steffen B. Hansen, P. M. Kristinsdottir, Jakob Schwander, and J.P. Steffensen. Data were recorded in parallel on paper in high resolution and digitally in 1 cm resolution. The main core was drilled during the GRIP project in 1989-1992 at the Summit of the Greenland ice sheet. The length is 3025 m. Present-day accumulation 0.23 m ice/yr. Data from the top 101.3 m comes from the S3 shallow core, but the two data sets have been fully integrated on a common depth scale. The data are given as H+ ion concentration versus depth (measured from the undisturbed surface in 1989), but the absolute calibration (H+ = 0.045 I^1.73) must be considered tentative. For more information on the measurements and calibration, see Hammer 1980 and Clausen et al. (1995). Please cite the Hammer (1980), Clausen et al. (1995), and ...
format Dataset
author Rasmussen, Sune Olander
Hansen, Steffen Bo
Hvidberg, Christine Schøtt
Dahl-Jensen, Dorthe
Steffensen, Jørgen Peder
author_facet Rasmussen, Sune Olander
Hansen, Steffen Bo
Hvidberg, Christine Schøtt
Dahl-Jensen, Dorthe
Steffensen, Jørgen Peder
author_sort Rasmussen, Sune Olander
title Electrical conductivity measurements (ECM) from the GRIP ice core, central Greenland ...
title_short Electrical conductivity measurements (ECM) from the GRIP ice core, central Greenland ...
title_full Electrical conductivity measurements (ECM) from the GRIP ice core, central Greenland ...
title_fullStr Electrical conductivity measurements (ECM) from the GRIP ice core, central Greenland ...
title_full_unstemmed Electrical conductivity measurements (ECM) from the GRIP ice core, central Greenland ...
title_sort electrical conductivity measurements (ecm) from the grip ice core, central greenland ...
publisher PANGAEA
publishDate 2022
url https://dx.doi.org/10.1594/pangaea.942944
https://doi.pangaea.de/10.1594/PANGAEA.942944
genre Greenland
GRIP
ice core
Ice Sheet
genre_facet Greenland
GRIP
ice core
Ice Sheet
op_relation https://dx.doi.org/10.5194/essd-15-3351-2023
https://dx.doi.org/10.3189/s0022143000015227
op_rights Creative Commons Attribution 4.0 International
https://creativecommons.org/licenses/by/4.0/legalcode
cc-by-4.0
op_doi https://doi.org/10.1594/pangaea.94294410.5194/essd-15-3351-202310.3189/s0022143000015227
_version_ 1797583743407357952