Publishing

A study has been made of the optical performance to be expected from an Antarctic Ritchey Chrtien telescope with a 2 m diameter primary mirror imaging directly onto a detector array in the K and L infrared windows. Near diffraction limited performance is provided across a flat 30 arcmin diameter fie...

Full description

Bibliographic Details
Main Authors: For Editorial Enquiries, P. R. Gillingham
Other Authors: The Pennsylvania State University CiteSeerX Archives
Format: Text
Language:English
Subjects:
Online Access:http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.8.3583
http://www.phys.unsw.edu.au/~mgb/Antbib/hobart_gillingham.pdf
id ftciteseerx:oai:CiteSeerX.psu:10.1.1.8.3583
record_format openpolar
spelling ftciteseerx:oai:CiteSeerX.psu:10.1.1.8.3583 2023-05-15T13:45:22+02:00 Publishing For Editorial Enquiries P. R. Gillingham The Pennsylvania State University CiteSeerX Archives application/pdf http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.8.3583 http://www.phys.unsw.edu.au/~mgb/Antbib/hobart_gillingham.pdf en eng http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.8.3583 http://www.phys.unsw.edu.au/~mgb/Antbib/hobart_gillingham.pdf Metadata may be used without restrictions as long as the oai identifier remains attached to it. http://www.phys.unsw.edu.au/~mgb/Antbib/hobart_gillingham.pdf text ftciteseerx 2016-01-08T19:16:20Z A study has been made of the optical performance to be expected from an Antarctic Ritchey Chrtien telescope with a 2 m diameter primary mirror imaging directly onto a detector array in the K and L infrared windows. Near diffraction limited performance is provided across a flat 30 arcmin diameter field by compensating the astigmatism and field curvature with a meniscus lens which also serves as the Dewar window. With baffling inside and Narcissus mirrors outside the Dewar, extraneous radiation can be kept to a low level. Text Antarc* Antarctic Unknown Antarctic Dewar ENVELOPE(-21.158,-21.158,-80.534,-80.534)
institution Open Polar
collection Unknown
op_collection_id ftciteseerx
language English
description A study has been made of the optical performance to be expected from an Antarctic Ritchey Chrtien telescope with a 2 m diameter primary mirror imaging directly onto a detector array in the K and L infrared windows. Near diffraction limited performance is provided across a flat 30 arcmin diameter field by compensating the astigmatism and field curvature with a meniscus lens which also serves as the Dewar window. With baffling inside and Narcissus mirrors outside the Dewar, extraneous radiation can be kept to a low level.
author2 The Pennsylvania State University CiteSeerX Archives
format Text
author For Editorial Enquiries
P. R. Gillingham
spellingShingle For Editorial Enquiries
P. R. Gillingham
Publishing
author_facet For Editorial Enquiries
P. R. Gillingham
author_sort For Editorial Enquiries
title Publishing
title_short Publishing
title_full Publishing
title_fullStr Publishing
title_full_unstemmed Publishing
title_sort publishing
url http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.8.3583
http://www.phys.unsw.edu.au/~mgb/Antbib/hobart_gillingham.pdf
long_lat ENVELOPE(-21.158,-21.158,-80.534,-80.534)
geographic Antarctic
Dewar
geographic_facet Antarctic
Dewar
genre Antarc*
Antarctic
genre_facet Antarc*
Antarctic
op_source http://www.phys.unsw.edu.au/~mgb/Antbib/hobart_gillingham.pdf
op_relation http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.8.3583
http://www.phys.unsw.edu.au/~mgb/Antbib/hobart_gillingham.pdf
op_rights Metadata may be used without restrictions as long as the oai identifier remains attached to it.
_version_ 1766223326541250560