Level-3 Data Processing- Daily

sent from the stations to ESRIN for instrument monitoring. The EGOI data has been interfaced at DFD and can be processed using the standard GDP processing chain. The on-line calibration parameters comput-ed by GDP in Kiruna will be used to process EGOI data (no straylight or polarisation correction...

Full description

Bibliographic Details
Main Authors: R. E. Meisner, W. Mett
Other Authors: The Pennsylvania State University CiteSeerX Archives
Format: Text
Language:English
Subjects:
Online Access:http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.624.7192
http://atmos.caf.dlr.de/gome/docs/loyola_97.pdf
id ftciteseerx:oai:CiteSeerX.psu:10.1.1.624.7192
record_format openpolar
spelling ftciteseerx:oai:CiteSeerX.psu:10.1.1.624.7192 2023-05-15T17:04:06+02:00 Level-3 Data Processing- Daily R. E. Meisner W. Mett The Pennsylvania State University CiteSeerX Archives application/pdf http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.624.7192 http://atmos.caf.dlr.de/gome/docs/loyola_97.pdf en eng http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.624.7192 http://atmos.caf.dlr.de/gome/docs/loyola_97.pdf Metadata may be used without restrictions as long as the oai identifier remains attached to it. http://atmos.caf.dlr.de/gome/docs/loyola_97.pdf text ftciteseerx 2016-01-08T15:10:05Z sent from the stations to ESRIN for instrument monitoring. The EGOI data has been interfaced at DFD and can be processed using the standard GDP processing chain. The on-line calibration parameters comput-ed by GDP in Kiruna will be used to process EGOI data (no straylight or polarisation correction possible with EGOI). Figure 2 shows the GOME NRT ground segment for EGOC and EGOI data processing. Using the calibration parameters from Kiruna, the EGOI ozone total column has only 0.2 % difference with respect to the EGOC product. The EGOI data is available at ESRIN two hours after acquisition. Text Kiruna Unknown Kiruna
institution Open Polar
collection Unknown
op_collection_id ftciteseerx
language English
description sent from the stations to ESRIN for instrument monitoring. The EGOI data has been interfaced at DFD and can be processed using the standard GDP processing chain. The on-line calibration parameters comput-ed by GDP in Kiruna will be used to process EGOI data (no straylight or polarisation correction possible with EGOI). Figure 2 shows the GOME NRT ground segment for EGOC and EGOI data processing. Using the calibration parameters from Kiruna, the EGOI ozone total column has only 0.2 % difference with respect to the EGOC product. The EGOI data is available at ESRIN two hours after acquisition.
author2 The Pennsylvania State University CiteSeerX Archives
format Text
author R. E. Meisner
W. Mett
spellingShingle R. E. Meisner
W. Mett
Level-3 Data Processing- Daily
author_facet R. E. Meisner
W. Mett
author_sort R. E. Meisner
title Level-3 Data Processing- Daily
title_short Level-3 Data Processing- Daily
title_full Level-3 Data Processing- Daily
title_fullStr Level-3 Data Processing- Daily
title_full_unstemmed Level-3 Data Processing- Daily
title_sort level-3 data processing- daily
url http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.624.7192
http://atmos.caf.dlr.de/gome/docs/loyola_97.pdf
geographic Kiruna
geographic_facet Kiruna
genre Kiruna
genre_facet Kiruna
op_source http://atmos.caf.dlr.de/gome/docs/loyola_97.pdf
op_relation http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.624.7192
http://atmos.caf.dlr.de/gome/docs/loyola_97.pdf
op_rights Metadata may be used without restrictions as long as the oai identifier remains attached to it.
_version_ 1766058147899768832