Engineering Applications in Permafrost Areas 545 Preservation of permafrost for a fuel storage tank

.The w e history is presented of the successful installation of an insulated and ventilated foundation pad for a two million gallon (9100 m3) fuel storage tank in Inuvik, N.W.T. Because the tank is only heated locally in the winter at the fuel pick-up point near the tank bottom, the tank temperature...