Thermal Load Reduction of Truck Tractor Sleeper Cabins

Copyright © 2008 SAE International Several configurations of truck tractor sleeper cabs were tested and modeled to investigate the potential to reduce heating and cooling loads. Two trucks were tested outdoors and a third was used as a control. Data from the testing were used to validate a computati...

Full description

Bibliographic Details
Main Author: Eric Sailor
Other Authors: The Pennsylvania State University CiteSeerX Archives
Format: Text
Language:English
Subjects:
Online Access:http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.527.3620
http://www.nrel.gov/vehiclesandfuels/fleettest/pdfs/43402.pdf
id ftciteseerx:oai:CiteSeerX.psu:10.1.1.527.3620
record_format openpolar
spelling ftciteseerx:oai:CiteSeerX.psu:10.1.1.527.3620 2023-05-15T14:57:45+02:00 Thermal Load Reduction of Truck Tractor Sleeper Cabins Eric Sailor The Pennsylvania State University CiteSeerX Archives application/pdf http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.527.3620 http://www.nrel.gov/vehiclesandfuels/fleettest/pdfs/43402.pdf en eng http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.527.3620 http://www.nrel.gov/vehiclesandfuels/fleettest/pdfs/43402.pdf Metadata may be used without restrictions as long as the oai identifier remains attached to it. http://www.nrel.gov/vehiclesandfuels/fleettest/pdfs/43402.pdf text ftciteseerx 2016-01-08T10:24:56Z Copyright © 2008 SAE International Several configurations of truck tractor sleeper cabs were tested and modeled to investigate the potential to reduce heating and cooling loads. Two trucks were tested outdoors and a third was used as a control. Data from the testing were used to validate a computational fluid dynamics (CFD) model and this model was used to predict reductions in cooling loads during daytime rest periods. The test configurations included the application of standard-equipped sleeper privacy curtain and window shades, an optional insulated or arctic sleeper curtain, and insulated window coverings. The standard curtain reduced sleeper area heating load by 21 % in one test truck, while the arctic curtain decreased it by 26%. Insulated window coverings reduced the heating load by 16 % in the other test truck and lowered daytime solar temperature gain by 8˚C. The lowered temperature resulted in a predicted 34 % reduction in cooling load from the model. Modeling also predicted doubling cab insulation could reduce cooling load by 35 % and up to 54 % with the sleeper curtain closed. Infrared images of the truck cabs identified other potential areas to reduce heat loss that included areas around window and door seals, at body and structural seams, and areas where insulation may be lacking around air circulation ducts. Text Arctic Unknown Arctic
institution Open Polar
collection Unknown
op_collection_id ftciteseerx
language English
description Copyright © 2008 SAE International Several configurations of truck tractor sleeper cabs were tested and modeled to investigate the potential to reduce heating and cooling loads. Two trucks were tested outdoors and a third was used as a control. Data from the testing were used to validate a computational fluid dynamics (CFD) model and this model was used to predict reductions in cooling loads during daytime rest periods. The test configurations included the application of standard-equipped sleeper privacy curtain and window shades, an optional insulated or arctic sleeper curtain, and insulated window coverings. The standard curtain reduced sleeper area heating load by 21 % in one test truck, while the arctic curtain decreased it by 26%. Insulated window coverings reduced the heating load by 16 % in the other test truck and lowered daytime solar temperature gain by 8˚C. The lowered temperature resulted in a predicted 34 % reduction in cooling load from the model. Modeling also predicted doubling cab insulation could reduce cooling load by 35 % and up to 54 % with the sleeper curtain closed. Infrared images of the truck cabs identified other potential areas to reduce heat loss that included areas around window and door seals, at body and structural seams, and areas where insulation may be lacking around air circulation ducts.
author2 The Pennsylvania State University CiteSeerX Archives
format Text
author Eric Sailor
spellingShingle Eric Sailor
Thermal Load Reduction of Truck Tractor Sleeper Cabins
author_facet Eric Sailor
author_sort Eric Sailor
title Thermal Load Reduction of Truck Tractor Sleeper Cabins
title_short Thermal Load Reduction of Truck Tractor Sleeper Cabins
title_full Thermal Load Reduction of Truck Tractor Sleeper Cabins
title_fullStr Thermal Load Reduction of Truck Tractor Sleeper Cabins
title_full_unstemmed Thermal Load Reduction of Truck Tractor Sleeper Cabins
title_sort thermal load reduction of truck tractor sleeper cabins
url http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.527.3620
http://www.nrel.gov/vehiclesandfuels/fleettest/pdfs/43402.pdf
geographic Arctic
geographic_facet Arctic
genre Arctic
genre_facet Arctic
op_source http://www.nrel.gov/vehiclesandfuels/fleettest/pdfs/43402.pdf
op_relation http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.527.3620
http://www.nrel.gov/vehiclesandfuels/fleettest/pdfs/43402.pdf
op_rights Metadata may be used without restrictions as long as the oai identifier remains attached to it.
_version_ 1766329870489485312