UC w 6 Submitted to Review of Scientific Instruments A Liquid-Helium-Cooled Absolute Reference Cold Load for Long-Wavelength Radiometric Calibration e Not to be taken from this room A liquid helium-cooled absolute reference cold load for long-wavelength r

ABSTRACT We describe a large (78-cm) diameter liquid-helium-cooled black-body absolute reference cold load for the calibration of microwave radiometers. The load provides an absolute calibration near the liquid helium (LHe) boiling point, accurate to better than 30 mK for wavelengths from 2.5 to 25...

Full description

Bibliographic Details
Main Authors: M Bensadoun, C Witebsky, G Smoot, G De Amici, A Kogut, S Levin, Marc Bensadoun, Chris Witebsky, George Smoot, Giovanni De Amici, A I Kogut, Steve Levin
Other Authors: The Pennsylvania State University CiteSeerX Archives
Format: Text
Language:English
Subjects:
Online Access:http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.1070.2769
id ftciteseerx:oai:CiteSeerX.psu:10.1.1.1070.2769
record_format openpolar
spelling ftciteseerx:oai:CiteSeerX.psu:10.1.1.1070.2769 2023-05-15T18:22:36+02:00 UC w 6 Submitted to Review of Scientific Instruments A Liquid-Helium-Cooled Absolute Reference Cold Load for Long-Wavelength Radiometric Calibration e Not to be taken from this room A liquid helium-cooled absolute reference cold load for long-wavelength r M Bensadoun C Witebsky G Smoot G De Amici A Kogut S Levin Marc Bensadoun Chris Witebsky George Smoot Giovanni De Amici A I Kogut Steve Levin The Pennsylvania State University CiteSeerX Archives application/pdf http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.1070.2769 en eng http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.1070.2769 Metadata may be used without restrictions as long as the oai identifier remains attached to it. https://digital.library.unt.edu/ark%3A/67531/metadc882907/m2/1/high_res_d/892912.pdf text ftciteseerx 2020-04-26T00:20:14Z ABSTRACT We describe a large (78-cm) diameter liquid-helium-cooled black-body absolute reference cold load for the calibration of microwave radiometers. The load provides an absolute calibration near the liquid helium (LHe) boiling point, accurate to better than 30 mK for wavelengths from 2.5 to 25 cm (12-1.2 GHz). The emission (from non-LHe temperature parts of the cold load) and reflection are small and well determined. Total corrections to the LHe boiling point temperature are 150 mK over the operating range. This cold load has been used at several wavelengths at the South Pole and at the White Mountain Research Station. In operation, the average LHe loss rate was 24.4 Vhr. Design considerations, radiometric and thermal performance and operational aspects are discussed. A comparison with other LHe-cooled reference loads including the predecessor of this cold load is given. Text South pole Unknown South Pole
institution Open Polar
collection Unknown
op_collection_id ftciteseerx
language English
description ABSTRACT We describe a large (78-cm) diameter liquid-helium-cooled black-body absolute reference cold load for the calibration of microwave radiometers. The load provides an absolute calibration near the liquid helium (LHe) boiling point, accurate to better than 30 mK for wavelengths from 2.5 to 25 cm (12-1.2 GHz). The emission (from non-LHe temperature parts of the cold load) and reflection are small and well determined. Total corrections to the LHe boiling point temperature are 150 mK over the operating range. This cold load has been used at several wavelengths at the South Pole and at the White Mountain Research Station. In operation, the average LHe loss rate was 24.4 Vhr. Design considerations, radiometric and thermal performance and operational aspects are discussed. A comparison with other LHe-cooled reference loads including the predecessor of this cold load is given.
author2 The Pennsylvania State University CiteSeerX Archives
format Text
author M Bensadoun
C Witebsky
G Smoot
G De Amici
A Kogut
S Levin
Marc Bensadoun
Chris Witebsky
George Smoot
Giovanni De Amici
A I Kogut
Steve Levin
spellingShingle M Bensadoun
C Witebsky
G Smoot
G De Amici
A Kogut
S Levin
Marc Bensadoun
Chris Witebsky
George Smoot
Giovanni De Amici
A I Kogut
Steve Levin
UC w 6 Submitted to Review of Scientific Instruments A Liquid-Helium-Cooled Absolute Reference Cold Load for Long-Wavelength Radiometric Calibration e Not to be taken from this room A liquid helium-cooled absolute reference cold load for long-wavelength r
author_facet M Bensadoun
C Witebsky
G Smoot
G De Amici
A Kogut
S Levin
Marc Bensadoun
Chris Witebsky
George Smoot
Giovanni De Amici
A I Kogut
Steve Levin
author_sort M Bensadoun
title UC w 6 Submitted to Review of Scientific Instruments A Liquid-Helium-Cooled Absolute Reference Cold Load for Long-Wavelength Radiometric Calibration e Not to be taken from this room A liquid helium-cooled absolute reference cold load for long-wavelength r
title_short UC w 6 Submitted to Review of Scientific Instruments A Liquid-Helium-Cooled Absolute Reference Cold Load for Long-Wavelength Radiometric Calibration e Not to be taken from this room A liquid helium-cooled absolute reference cold load for long-wavelength r
title_full UC w 6 Submitted to Review of Scientific Instruments A Liquid-Helium-Cooled Absolute Reference Cold Load for Long-Wavelength Radiometric Calibration e Not to be taken from this room A liquid helium-cooled absolute reference cold load for long-wavelength r
title_fullStr UC w 6 Submitted to Review of Scientific Instruments A Liquid-Helium-Cooled Absolute Reference Cold Load for Long-Wavelength Radiometric Calibration e Not to be taken from this room A liquid helium-cooled absolute reference cold load for long-wavelength r
title_full_unstemmed UC w 6 Submitted to Review of Scientific Instruments A Liquid-Helium-Cooled Absolute Reference Cold Load for Long-Wavelength Radiometric Calibration e Not to be taken from this room A liquid helium-cooled absolute reference cold load for long-wavelength r
title_sort uc w 6 submitted to review of scientific instruments a liquid-helium-cooled absolute reference cold load for long-wavelength radiometric calibration e not to be taken from this room a liquid helium-cooled absolute reference cold load for long-wavelength r
url http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.1070.2769
geographic South Pole
geographic_facet South Pole
genre South pole
genre_facet South pole
op_source https://digital.library.unt.edu/ark%3A/67531/metadc882907/m2/1/high_res_d/892912.pdf
op_relation http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.1070.2769
op_rights Metadata may be used without restrictions as long as the oai identifier remains attached to it.
_version_ 1766202014672355328