Standard operation procedures and performance of the MICADAS radiocarbon laboratory at Alfred Wegener Institute (AWI), Germany

The radiocarbon analysis laboratory at Alfred Wegener Institute Helmholtz Centre for Polar and Marine Research (AWI) is equipped with an accelerator mass spectrometer (AMS) MICADAS (MIni CArbon Dating System). The laboratory provides routine 14C analyses on bulk organic matter, plant fragments, diss...

Full description

Bibliographic Details
Published in:Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Main Authors: Mollenhauer, Gesine, Grotheer, Hendrik, Gentz, Torben, Bonk, Elizabeth, Hefter, Jens H.
Format: Article in Journal/Newspaper
Language:unknown
Published: 2021
Subjects:
Online Access:https://epic.awi.de/id/eprint/54265/
https://doi.org/10.1016/j.nimb.2021.03.016
https://hdl.handle.net/10013/epic.af698461-5a27-42d4-96a7-d97f8d4545d0
id ftawi:oai:epic.awi.de:54265
record_format openpolar
spelling ftawi:oai:epic.awi.de:54265 2024-09-15T17:36:34+00:00 Standard operation procedures and performance of the MICADAS radiocarbon laboratory at Alfred Wegener Institute (AWI), Germany Mollenhauer, Gesine Grotheer, Hendrik Gentz, Torben Bonk, Elizabeth Hefter, Jens H. 2021-04-03 https://epic.awi.de/id/eprint/54265/ https://doi.org/10.1016/j.nimb.2021.03.016 https://hdl.handle.net/10013/epic.af698461-5a27-42d4-96a7-d97f8d4545d0 unknown Mollenhauer, G. orcid:0000-0001-5138-564X , Grotheer, H. orcid:0000-0003-0207-3767 , Gentz, T. orcid:0000-0001-6739-5359 , Bonk, E. and Hefter, J. H. orcid:0000-0002-5823-1966 (2021) Standard operation procedures and performance of the MICADAS radiocarbon laboratory at Alfred Wegener Institute (AWI), Germany , Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 496 , pp. 45-51 . doi:10.1016/j.nimb.2021.03.016 <https://doi.org/10.1016/j.nimb.2021.03.016> , hdl:10013/epic.af698461-5a27-42d4-96a7-d97f8d4545d0 EPIC3Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 496, pp. 45-51, ISSN: 0168583X Article isiRev 2021 ftawi https://doi.org/10.1016/j.nimb.2021.03.016 2024-06-24T04:27:29Z The radiocarbon analysis laboratory at Alfred Wegener Institute Helmholtz Centre for Polar and Marine Research (AWI) is equipped with an accelerator mass spectrometer (AMS) MICADAS (MIni CArbon Dating System). The laboratory provides routine 14C analyses on bulk organic matter, plant fragments, dissolved and particulate organic matter, individual molecular lipids, and carbonate (micro-) fossils with the aim to foster international research efforts in vulnerable high latitudes. The AWI MICADAS allows AMS 14C analysis on graphite targets as well as on CO2 samples via gas injection into the hybrid ion source. The laboratory thus provides reliable datasets even if only small amounts of sample material are available, a problem often encountered in polar research. Here we describe the standard operation procedures and sample preparation methods employed, and demonstrate the instrument performance and data quality based on repeat analysis of international reference materials. Article in Journal/Newspaper Alfred Wegener Institute Alfred Wegener Institute for Polar- and Marine Research (AWI): ePIC (electronic Publication Information Center) Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 496 45 51
institution Open Polar
collection Alfred Wegener Institute for Polar- and Marine Research (AWI): ePIC (electronic Publication Information Center)
op_collection_id ftawi
language unknown
description The radiocarbon analysis laboratory at Alfred Wegener Institute Helmholtz Centre for Polar and Marine Research (AWI) is equipped with an accelerator mass spectrometer (AMS) MICADAS (MIni CArbon Dating System). The laboratory provides routine 14C analyses on bulk organic matter, plant fragments, dissolved and particulate organic matter, individual molecular lipids, and carbonate (micro-) fossils with the aim to foster international research efforts in vulnerable high latitudes. The AWI MICADAS allows AMS 14C analysis on graphite targets as well as on CO2 samples via gas injection into the hybrid ion source. The laboratory thus provides reliable datasets even if only small amounts of sample material are available, a problem often encountered in polar research. Here we describe the standard operation procedures and sample preparation methods employed, and demonstrate the instrument performance and data quality based on repeat analysis of international reference materials.
format Article in Journal/Newspaper
author Mollenhauer, Gesine
Grotheer, Hendrik
Gentz, Torben
Bonk, Elizabeth
Hefter, Jens H.
spellingShingle Mollenhauer, Gesine
Grotheer, Hendrik
Gentz, Torben
Bonk, Elizabeth
Hefter, Jens H.
Standard operation procedures and performance of the MICADAS radiocarbon laboratory at Alfred Wegener Institute (AWI), Germany
author_facet Mollenhauer, Gesine
Grotheer, Hendrik
Gentz, Torben
Bonk, Elizabeth
Hefter, Jens H.
author_sort Mollenhauer, Gesine
title Standard operation procedures and performance of the MICADAS radiocarbon laboratory at Alfred Wegener Institute (AWI), Germany
title_short Standard operation procedures and performance of the MICADAS radiocarbon laboratory at Alfred Wegener Institute (AWI), Germany
title_full Standard operation procedures and performance of the MICADAS radiocarbon laboratory at Alfred Wegener Institute (AWI), Germany
title_fullStr Standard operation procedures and performance of the MICADAS radiocarbon laboratory at Alfred Wegener Institute (AWI), Germany
title_full_unstemmed Standard operation procedures and performance of the MICADAS radiocarbon laboratory at Alfred Wegener Institute (AWI), Germany
title_sort standard operation procedures and performance of the micadas radiocarbon laboratory at alfred wegener institute (awi), germany
publishDate 2021
url https://epic.awi.de/id/eprint/54265/
https://doi.org/10.1016/j.nimb.2021.03.016
https://hdl.handle.net/10013/epic.af698461-5a27-42d4-96a7-d97f8d4545d0
genre Alfred Wegener Institute
genre_facet Alfred Wegener Institute
op_source EPIC3Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 496, pp. 45-51, ISSN: 0168583X
op_relation Mollenhauer, G. orcid:0000-0001-5138-564X , Grotheer, H. orcid:0000-0003-0207-3767 , Gentz, T. orcid:0000-0001-6739-5359 , Bonk, E. and Hefter, J. H. orcid:0000-0002-5823-1966 (2021) Standard operation procedures and performance of the MICADAS radiocarbon laboratory at Alfred Wegener Institute (AWI), Germany , Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 496 , pp. 45-51 . doi:10.1016/j.nimb.2021.03.016 <https://doi.org/10.1016/j.nimb.2021.03.016> , hdl:10013/epic.af698461-5a27-42d4-96a7-d97f8d4545d0
op_doi https://doi.org/10.1016/j.nimb.2021.03.016
container_title Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
container_volume 496
container_start_page 45
op_container_end_page 51
_version_ 1810490326364717056