Performance Studies of the Acoustic Module for the IceCube Upgrade

The IceCube Upgrade will augment the existing IceCube Neutrino Observatory by deploying 700 additional optical sensor modules and calibration devices within its center at a depth of 1.5 to 2.5 km in the Antarctic ice. One goal of the Upgrade is to improve the positioning calibration of the optical s...

Full description

Bibliographic Details
Main Authors: Benning, Charlotte, Borowka, Jürgen, Günther, Christoph, Gries, Oliver, Zierke, Simon
Format: Text
Language:unknown
Published: 2023
Subjects:
Online Access:http://arxiv.org/abs/2308.08506
id ftarxivpreprints:oai:arXiv.org:2308.08506
record_format openpolar
spelling ftarxivpreprints:oai:arXiv.org:2308.08506 2023-09-05T13:12:17+02:00 Performance Studies of the Acoustic Module for the IceCube Upgrade Benning, Charlotte Borowka, Jürgen Günther, Christoph Gries, Oliver Zierke, Simon 2023-08-16 http://arxiv.org/abs/2308.08506 unknown http://arxiv.org/abs/2308.08506 Astrophysics - High Energy Astrophysical Phenomena Astrophysics - Instrumentation and Methods for Astrophysics Physics - Instrumentation and Detectors text 2023 ftarxivpreprints 2023-08-20T01:05:36Z The IceCube Upgrade will augment the existing IceCube Neutrino Observatory by deploying 700 additional optical sensor modules and calibration devices within its center at a depth of 1.5 to 2.5 km in the Antarctic ice. One goal of the Upgrade is to improve the positioning calibration of the optical sensors to increase the angular resolution for neutrino directional reconstruction. An acoustic calibration system will be deployed to explore the capability of achieving this using trilateration of propagation times of acoustic signals. Ten Acoustic Modules (AM) capable of sending and receiving acoustic signals with frequencies from 5 to 30 kHz will be installed within the detector volume. Additionally, compact acoustic sensors inside 15 optical sensor modules will complement the acoustic calibration system. With this system, we aim for an accuracy of a few tens of cm to localize the Acoustic Modules and sensors. Due to the longer attenuation length of sound compared to light within the ice, acoustic position calibration is especially interesting for the upcoming IceCube-Gen2 detector, which will have a string spacing of around 240 m. In this contribution we present an overview of the technical design of the Acoustic Module as well as results of performance tests with a first complete prototype. Comment: Presented at the 38th International Cosmic Ray Conference (ICRC2023). See arXiv:2307.13048 for all IceCube-Gen2 contributions Text Antarc* Antarctic ArXiv.org (Cornell University Library) Antarctic The Antarctic
institution Open Polar
collection ArXiv.org (Cornell University Library)
op_collection_id ftarxivpreprints
language unknown
topic Astrophysics - High Energy Astrophysical Phenomena
Astrophysics - Instrumentation and Methods for Astrophysics
Physics - Instrumentation and Detectors
spellingShingle Astrophysics - High Energy Astrophysical Phenomena
Astrophysics - Instrumentation and Methods for Astrophysics
Physics - Instrumentation and Detectors
Benning, Charlotte
Borowka, Jürgen
Günther, Christoph
Gries, Oliver
Zierke, Simon
Performance Studies of the Acoustic Module for the IceCube Upgrade
topic_facet Astrophysics - High Energy Astrophysical Phenomena
Astrophysics - Instrumentation and Methods for Astrophysics
Physics - Instrumentation and Detectors
description The IceCube Upgrade will augment the existing IceCube Neutrino Observatory by deploying 700 additional optical sensor modules and calibration devices within its center at a depth of 1.5 to 2.5 km in the Antarctic ice. One goal of the Upgrade is to improve the positioning calibration of the optical sensors to increase the angular resolution for neutrino directional reconstruction. An acoustic calibration system will be deployed to explore the capability of achieving this using trilateration of propagation times of acoustic signals. Ten Acoustic Modules (AM) capable of sending and receiving acoustic signals with frequencies from 5 to 30 kHz will be installed within the detector volume. Additionally, compact acoustic sensors inside 15 optical sensor modules will complement the acoustic calibration system. With this system, we aim for an accuracy of a few tens of cm to localize the Acoustic Modules and sensors. Due to the longer attenuation length of sound compared to light within the ice, acoustic position calibration is especially interesting for the upcoming IceCube-Gen2 detector, which will have a string spacing of around 240 m. In this contribution we present an overview of the technical design of the Acoustic Module as well as results of performance tests with a first complete prototype. Comment: Presented at the 38th International Cosmic Ray Conference (ICRC2023). See arXiv:2307.13048 for all IceCube-Gen2 contributions
format Text
author Benning, Charlotte
Borowka, Jürgen
Günther, Christoph
Gries, Oliver
Zierke, Simon
author_facet Benning, Charlotte
Borowka, Jürgen
Günther, Christoph
Gries, Oliver
Zierke, Simon
author_sort Benning, Charlotte
title Performance Studies of the Acoustic Module for the IceCube Upgrade
title_short Performance Studies of the Acoustic Module for the IceCube Upgrade
title_full Performance Studies of the Acoustic Module for the IceCube Upgrade
title_fullStr Performance Studies of the Acoustic Module for the IceCube Upgrade
title_full_unstemmed Performance Studies of the Acoustic Module for the IceCube Upgrade
title_sort performance studies of the acoustic module for the icecube upgrade
publishDate 2023
url http://arxiv.org/abs/2308.08506
geographic Antarctic
The Antarctic
geographic_facet Antarctic
The Antarctic
genre Antarc*
Antarctic
genre_facet Antarc*
Antarctic
op_relation http://arxiv.org/abs/2308.08506
_version_ 1776199655191740416