Refining the IceCube detector geometry using muon and LED calibration data

The IceCube Neutrino Observatory deployed 5160 digital optical modules (DOMs) on 86 cables, called strings, in a cubic kilometer of deep glacial ice below the geographic South Pole. These record the Cherenkov light of passing charged particles. Knowledge of the DOM positions is vital for event recon...

Full description

Bibliographic Details
Main Authors: Janson, Matti, Philippen, Saskia, Rongen, Martin
Format: Text
Language:unknown
Published: 2023
Subjects:
Online Access:http://arxiv.org/abs/2308.05330
id ftarxivpreprints:oai:arXiv.org:2308.05330
record_format openpolar
spelling ftarxivpreprints:oai:arXiv.org:2308.05330 2023-09-05T13:23:19+02:00 Refining the IceCube detector geometry using muon and LED calibration data Janson, Matti Philippen, Saskia Rongen, Martin 2023-08-10 http://arxiv.org/abs/2308.05330 unknown http://arxiv.org/abs/2308.05330 Astrophysics - High Energy Astrophysical Phenomena text 2023 ftarxivpreprints 2023-08-16T17:52:45Z The IceCube Neutrino Observatory deployed 5160 digital optical modules (DOMs) on 86 cables, called strings, in a cubic kilometer of deep glacial ice below the geographic South Pole. These record the Cherenkov light of passing charged particles. Knowledge of the DOM positions is vital for event reconstruction. While vertical positions have been calibrated, previous in-situ geometry calibration methods have been unable to measure horizontal deviations from the surface positions, largely due to degeneracies with ice model uncertainties. Thus the lateral position of the surface position of each hole is to date in almost all cases used as the lateral position of all DOMs on a given string. With the recent advances in ice modeling, two new in-situ measurements have now been undertaken. Using a large sample of muon tracks, the individual positions of all DOMs on a small number of strings around the center of the detector have been fitted. Verifying the results against LED calibration data shows that the string-average corrections improve detector modeling. Directly fitting string-average geometry corrections for the full array using LED data agrees with the average corrections as derived from muons where available. Analyses are now ongoing to obtain per-DOM positions using both methods and in addition, methods are being developed to correct the recorded arrival times for the expected scattering delay, allowing for multilateration of the positions using nanosecond-precision propagation delays. Comment: Presented at the 38th International Cosmic Ray Conference (ICRC2023). See arXiv:2307.13047 for all IceCube contributions Text South pole ArXiv.org (Cornell University Library) South Pole
institution Open Polar
collection ArXiv.org (Cornell University Library)
op_collection_id ftarxivpreprints
language unknown
topic Astrophysics - High Energy Astrophysical Phenomena
spellingShingle Astrophysics - High Energy Astrophysical Phenomena
Janson, Matti
Philippen, Saskia
Rongen, Martin
Refining the IceCube detector geometry using muon and LED calibration data
topic_facet Astrophysics - High Energy Astrophysical Phenomena
description The IceCube Neutrino Observatory deployed 5160 digital optical modules (DOMs) on 86 cables, called strings, in a cubic kilometer of deep glacial ice below the geographic South Pole. These record the Cherenkov light of passing charged particles. Knowledge of the DOM positions is vital for event reconstruction. While vertical positions have been calibrated, previous in-situ geometry calibration methods have been unable to measure horizontal deviations from the surface positions, largely due to degeneracies with ice model uncertainties. Thus the lateral position of the surface position of each hole is to date in almost all cases used as the lateral position of all DOMs on a given string. With the recent advances in ice modeling, two new in-situ measurements have now been undertaken. Using a large sample of muon tracks, the individual positions of all DOMs on a small number of strings around the center of the detector have been fitted. Verifying the results against LED calibration data shows that the string-average corrections improve detector modeling. Directly fitting string-average geometry corrections for the full array using LED data agrees with the average corrections as derived from muons where available. Analyses are now ongoing to obtain per-DOM positions using both methods and in addition, methods are being developed to correct the recorded arrival times for the expected scattering delay, allowing for multilateration of the positions using nanosecond-precision propagation delays. Comment: Presented at the 38th International Cosmic Ray Conference (ICRC2023). See arXiv:2307.13047 for all IceCube contributions
format Text
author Janson, Matti
Philippen, Saskia
Rongen, Martin
author_facet Janson, Matti
Philippen, Saskia
Rongen, Martin
author_sort Janson, Matti
title Refining the IceCube detector geometry using muon and LED calibration data
title_short Refining the IceCube detector geometry using muon and LED calibration data
title_full Refining the IceCube detector geometry using muon and LED calibration data
title_fullStr Refining the IceCube detector geometry using muon and LED calibration data
title_full_unstemmed Refining the IceCube detector geometry using muon and LED calibration data
title_sort refining the icecube detector geometry using muon and led calibration data
publishDate 2023
url http://arxiv.org/abs/2308.05330
geographic South Pole
geographic_facet South Pole
genre South pole
genre_facet South pole
op_relation http://arxiv.org/abs/2308.05330
_version_ 1776203892296515584