Dynamic Viscosity of Methane Hydrate Systems from Non-Einsteinian, Plasma-Functionalized Carbon Nanotube Nanofluids

The viscosity of oxygen-functionalized multi-walled carbon nanotube (O-MWCNT) nanofluids was measured for concentrations from 0.1 to 10 ppm under conditions of 0 to 30 MPag pressures and 0 to 10 C temperatures. The presence of O-MWCNTs did not affect the temperature dependence of viscosity but did r...

Full description

Bibliographic Details
Published in:Nanoscale
Main Authors: McElligott, Adam, Guerra, André, Du, Chong Yang, Rey, Alejandro D., Meunier, Jean-Luc, Servio, Phillip
Format: Text
Language:unknown
Published: 2023
Subjects:
Online Access:http://arxiv.org/abs/2306.16253
https://doi.org/10.1039/D2NR02712G
id ftarxivpreprints:oai:arXiv.org:2306.16253
record_format openpolar
spelling ftarxivpreprints:oai:arXiv.org:2306.16253 2023-09-05T13:21:07+02:00 Dynamic Viscosity of Methane Hydrate Systems from Non-Einsteinian, Plasma-Functionalized Carbon Nanotube Nanofluids McElligott, Adam Guerra, André Du, Chong Yang Rey, Alejandro D. Meunier, Jean-Luc Servio, Phillip 2023-06-28 http://arxiv.org/abs/2306.16253 https://doi.org/10.1039/D2NR02712G unknown http://arxiv.org/abs/2306.16253 Nanoscale, 2022,14, 10211-10225 doi:10.1039/D2NR02712G Physics - Applied Physics text 2023 ftarxivpreprints https://doi.org/10.1039/D2NR02712G 2023-08-16T17:47:39Z The viscosity of oxygen-functionalized multi-walled carbon nanotube (O-MWCNT) nanofluids was measured for concentrations from 0.1 to 10 ppm under conditions of 0 to 30 MPag pressures and 0 to 10 C temperatures. The presence of O-MWCNTs did not affect the temperature dependence of viscosity but did reduce the effective viscosity of solution due to cumulative hydrogen bond-disrupting surface effects, which overcame internal drag forces. O-MWCNTs added a weak pressure dependence to the viscosity of solution because of their ability to align more with the flow direction as pressure increased. In the liquid to hydrate phase transition, the times to reach the maximum viscosity were faster in O-MWCNT systems compared to the pure water baseline. However, the presence of O-MWCNTs limited the conditions at which hydrates formed as increased nanoparticle collisions in those systems inhibited the formation of critical clusters of hydrate nuclei. The times to viscosity values most relevant to technological applications were minimally 28.02 % (200 mPa s) and 21.08 % (500 mPa s) slower than the baseline, both in the 1 ppm system, even though all systems were faster to the final viscosity. This was attributed to O-MWCNT entanglement, which resulted in a hydrate slurry occurring at lower viscosity values. Text Methane hydrate ArXiv.org (Cornell University Library) Nanoscale 14 28 10211 10225
institution Open Polar
collection ArXiv.org (Cornell University Library)
op_collection_id ftarxivpreprints
language unknown
topic Physics - Applied Physics
spellingShingle Physics - Applied Physics
McElligott, Adam
Guerra, André
Du, Chong Yang
Rey, Alejandro D.
Meunier, Jean-Luc
Servio, Phillip
Dynamic Viscosity of Methane Hydrate Systems from Non-Einsteinian, Plasma-Functionalized Carbon Nanotube Nanofluids
topic_facet Physics - Applied Physics
description The viscosity of oxygen-functionalized multi-walled carbon nanotube (O-MWCNT) nanofluids was measured for concentrations from 0.1 to 10 ppm under conditions of 0 to 30 MPag pressures and 0 to 10 C temperatures. The presence of O-MWCNTs did not affect the temperature dependence of viscosity but did reduce the effective viscosity of solution due to cumulative hydrogen bond-disrupting surface effects, which overcame internal drag forces. O-MWCNTs added a weak pressure dependence to the viscosity of solution because of their ability to align more with the flow direction as pressure increased. In the liquid to hydrate phase transition, the times to reach the maximum viscosity were faster in O-MWCNT systems compared to the pure water baseline. However, the presence of O-MWCNTs limited the conditions at which hydrates formed as increased nanoparticle collisions in those systems inhibited the formation of critical clusters of hydrate nuclei. The times to viscosity values most relevant to technological applications were minimally 28.02 % (200 mPa s) and 21.08 % (500 mPa s) slower than the baseline, both in the 1 ppm system, even though all systems were faster to the final viscosity. This was attributed to O-MWCNT entanglement, which resulted in a hydrate slurry occurring at lower viscosity values.
format Text
author McElligott, Adam
Guerra, André
Du, Chong Yang
Rey, Alejandro D.
Meunier, Jean-Luc
Servio, Phillip
author_facet McElligott, Adam
Guerra, André
Du, Chong Yang
Rey, Alejandro D.
Meunier, Jean-Luc
Servio, Phillip
author_sort McElligott, Adam
title Dynamic Viscosity of Methane Hydrate Systems from Non-Einsteinian, Plasma-Functionalized Carbon Nanotube Nanofluids
title_short Dynamic Viscosity of Methane Hydrate Systems from Non-Einsteinian, Plasma-Functionalized Carbon Nanotube Nanofluids
title_full Dynamic Viscosity of Methane Hydrate Systems from Non-Einsteinian, Plasma-Functionalized Carbon Nanotube Nanofluids
title_fullStr Dynamic Viscosity of Methane Hydrate Systems from Non-Einsteinian, Plasma-Functionalized Carbon Nanotube Nanofluids
title_full_unstemmed Dynamic Viscosity of Methane Hydrate Systems from Non-Einsteinian, Plasma-Functionalized Carbon Nanotube Nanofluids
title_sort dynamic viscosity of methane hydrate systems from non-einsteinian, plasma-functionalized carbon nanotube nanofluids
publishDate 2023
url http://arxiv.org/abs/2306.16253
https://doi.org/10.1039/D2NR02712G
genre Methane hydrate
genre_facet Methane hydrate
op_relation http://arxiv.org/abs/2306.16253
Nanoscale, 2022,14, 10211-10225
doi:10.1039/D2NR02712G
op_doi https://doi.org/10.1039/D2NR02712G
container_title Nanoscale
container_volume 14
container_issue 28
container_start_page 10211
op_container_end_page 10225
_version_ 1776201730789212160