id ftarxivpreprints:oai:arXiv.org:1506.06953
record_format openpolar
spelling ftarxivpreprints:oai:arXiv.org:1506.06953 2023-09-05T13:12:31+02:00 The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat Gudmundsson, J. E. Ade, P. A. R. Amiri, M. Benton, S. J. Bock, J. J. Bond, J. R. Bryan, S. A. Chiang, H. C. Contaldi, C. R. Crill, B. P. Doré, O. Filippini, J. P. Fraisse, A. A. Gambrel, A. Gandilo, N. N. Hasselfield, M. Halpern, M. Hilton, G. C. Holmes, W. Hristov, V. V. Irwin, K. D. Jones, W. C. Kermish, Z. MacTavish, C. J. Mason, P. V. Megerian, K. Moncelsi, L. Montroy, T. E. Morford, T. A. Nagy, J. M. Netterfield, C. B. Rahlin, A. S. Reintsema, C. D. Ruhl, J. E. Runyan, M. C. Shariff, J. A. Soler, J. D. Trangsrud, A. Tucker, C. Tucker, R. S. Turner, A. D. Wiebe, D. V. Young, E. 2015-06-23 http://arxiv.org/abs/1506.06953 https://doi.org/10.1016/j.cryogenics.2015.09.002 unknown http://arxiv.org/abs/1506.06953 doi:10.1016/j.cryogenics.2015.09.002 Astrophysics - Instrumentation and Methods for Astrophysics Astrophysics - Cosmology and Nongalactic Astrophysics Physics - Instrumentation and Detectors text 2015 ftarxivpreprints https://doi.org/10.1016/j.cryogenics.2015.09.002 2023-08-16T13:41:11Z We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid helium tank and a smaller superfluid tank, allowing the latter to operate at 1.6 K as long as there is liquid in the 4.2 K main tank. Each telescope houses a closed cycle helium-3 adsorption refrigerator that further cools the focal planes down to 300 mK. Liquid helium vapor from the main tank is routed through heat exchangers that cool radiation shields, providing negative thermal feedback. The system performed successfully during a 17 day flight in the 2014-2015 Antarctic summer. The cryostat had a total hold time of 16.8 days, with 15.9 days occurring during flight. Comment: 15 pgs, 17 figs Text Antarc* Antarctic ArXiv.org (Cornell University Library) Antarctic Cryogenics 72 65 76
institution Open Polar
collection ArXiv.org (Cornell University Library)
op_collection_id ftarxivpreprints
language unknown
topic Astrophysics - Instrumentation and Methods for Astrophysics
Astrophysics - Cosmology and Nongalactic Astrophysics
Physics - Instrumentation and Detectors
spellingShingle Astrophysics - Instrumentation and Methods for Astrophysics
Astrophysics - Cosmology and Nongalactic Astrophysics
Physics - Instrumentation and Detectors
Gudmundsson, J. E.
Ade, P. A. R.
Amiri, M.
Benton, S. J.
Bock, J. J.
Bond, J. R.
Bryan, S. A.
Chiang, H. C.
Contaldi, C. R.
Crill, B. P.
Doré, O.
Filippini, J. P.
Fraisse, A. A.
Gambrel, A.
Gandilo, N. N.
Hasselfield, M.
Halpern, M.
Hilton, G. C.
Holmes, W.
Hristov, V. V.
Irwin, K. D.
Jones, W. C.
Kermish, Z.
MacTavish, C. J.
Mason, P. V.
Megerian, K.
Moncelsi, L.
Montroy, T. E.
Morford, T. A.
Nagy, J. M.
Netterfield, C. B.
Rahlin, A. S.
Reintsema, C. D.
Ruhl, J. E.
Runyan, M. C.
Shariff, J. A.
Soler, J. D.
Trangsrud, A.
Tucker, C.
Tucker, R. S.
Turner, A. D.
Wiebe, D. V.
Young, E.
The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat
topic_facet Astrophysics - Instrumentation and Methods for Astrophysics
Astrophysics - Cosmology and Nongalactic Astrophysics
Physics - Instrumentation and Detectors
description We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid helium tank and a smaller superfluid tank, allowing the latter to operate at 1.6 K as long as there is liquid in the 4.2 K main tank. Each telescope houses a closed cycle helium-3 adsorption refrigerator that further cools the focal planes down to 300 mK. Liquid helium vapor from the main tank is routed through heat exchangers that cool radiation shields, providing negative thermal feedback. The system performed successfully during a 17 day flight in the 2014-2015 Antarctic summer. The cryostat had a total hold time of 16.8 days, with 15.9 days occurring during flight. Comment: 15 pgs, 17 figs
format Text
author Gudmundsson, J. E.
Ade, P. A. R.
Amiri, M.
Benton, S. J.
Bock, J. J.
Bond, J. R.
Bryan, S. A.
Chiang, H. C.
Contaldi, C. R.
Crill, B. P.
Doré, O.
Filippini, J. P.
Fraisse, A. A.
Gambrel, A.
Gandilo, N. N.
Hasselfield, M.
Halpern, M.
Hilton, G. C.
Holmes, W.
Hristov, V. V.
Irwin, K. D.
Jones, W. C.
Kermish, Z.
MacTavish, C. J.
Mason, P. V.
Megerian, K.
Moncelsi, L.
Montroy, T. E.
Morford, T. A.
Nagy, J. M.
Netterfield, C. B.
Rahlin, A. S.
Reintsema, C. D.
Ruhl, J. E.
Runyan, M. C.
Shariff, J. A.
Soler, J. D.
Trangsrud, A.
Tucker, C.
Tucker, R. S.
Turner, A. D.
Wiebe, D. V.
Young, E.
author_facet Gudmundsson, J. E.
Ade, P. A. R.
Amiri, M.
Benton, S. J.
Bock, J. J.
Bond, J. R.
Bryan, S. A.
Chiang, H. C.
Contaldi, C. R.
Crill, B. P.
Doré, O.
Filippini, J. P.
Fraisse, A. A.
Gambrel, A.
Gandilo, N. N.
Hasselfield, M.
Halpern, M.
Hilton, G. C.
Holmes, W.
Hristov, V. V.
Irwin, K. D.
Jones, W. C.
Kermish, Z.
MacTavish, C. J.
Mason, P. V.
Megerian, K.
Moncelsi, L.
Montroy, T. E.
Morford, T. A.
Nagy, J. M.
Netterfield, C. B.
Rahlin, A. S.
Reintsema, C. D.
Ruhl, J. E.
Runyan, M. C.
Shariff, J. A.
Soler, J. D.
Trangsrud, A.
Tucker, C.
Tucker, R. S.
Turner, A. D.
Wiebe, D. V.
Young, E.
author_sort Gudmundsson, J. E.
title The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat
title_short The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat
title_full The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat
title_fullStr The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat
title_full_unstemmed The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat
title_sort thermal design, characterization, and performance of the spider long-duration balloon cryostat
publishDate 2015
url http://arxiv.org/abs/1506.06953
https://doi.org/10.1016/j.cryogenics.2015.09.002
geographic Antarctic
geographic_facet Antarctic
genre Antarc*
Antarctic
genre_facet Antarc*
Antarctic
op_relation http://arxiv.org/abs/1506.06953
doi:10.1016/j.cryogenics.2015.09.002
op_doi https://doi.org/10.1016/j.cryogenics.2015.09.002
container_title Cryogenics
container_volume 72
container_start_page 65
op_container_end_page 76
_version_ 1776200616420311040