Focal ratio degradation in lightly-fused hexabundles

We are now moving into an era where multi-object wide-field surveys, which traditionally use single fibres to observe many targets simultaneously, can exploit compact integral field units in place of single fibres. Current multi-object integral field instruments such as SAMI (Croom et al. 2012; Brya...

Full description

Bibliographic Details
Published in:Monthly Notices of the Royal Astronomical Society
Main Authors: Bryant, Julia, Bland-Hawthorn, Joss, Fogarty, Lisa, Lawrence, Jon, Croom, Scott
Format: Text
Language:unknown
Published: 2013
Subjects:
Online Access:http://arxiv.org/abs/1311.6865
https://doi.org/10.1093/mnras/stt2254
id ftarxivpreprints:oai:arXiv.org:1311.6865
record_format openpolar
spelling ftarxivpreprints:oai:arXiv.org:1311.6865 2023-09-05T13:22:56+02:00 Focal ratio degradation in lightly-fused hexabundles Bryant, Julia Bland-Hawthorn, Joss Fogarty, Lisa Lawrence, Jon Croom, Scott 2013-11-26 http://arxiv.org/abs/1311.6865 https://doi.org/10.1093/mnras/stt2254 unknown http://arxiv.org/abs/1311.6865 doi:10.1093/mnras/stt2254 Astrophysics - Instrumentation and Methods for Astrophysics text 2013 ftarxivpreprints https://doi.org/10.1093/mnras/stt2254 2023-08-16T13:11:34Z We are now moving into an era where multi-object wide-field surveys, which traditionally use single fibres to observe many targets simultaneously, can exploit compact integral field units in place of single fibres. Current multi-object integral field instruments such as SAMI (Croom et al. 2012; Bryant et al. 2012a) have driven the development of new imaging fibre bundles (hexabundles) for multi-object spectrographs. We have characterised the performance of hexabundles with different cladding thicknesses and compared them to that of the same type of bare fibre, across the range of fill-fractions and input f-ratios likely in an IFU instrument. Hexabundles with 7-cores and 61-cores were tested for focal ratio degradation (FRD), throughput and cross-talk when fed with inputs from F/3.4 to >F/8. The five 7-core bundles have cladding thickness ranging from 1 to 8 microns, and the 61-core bundles have 5micron cladding. As expected, the FRD improves as the input focal ratio decreases. We find that the FRD and throughput of the cores in the hexabundles match the performance of single fibres of the same material at low input f-ratios. The performance results presented can be used to set a limit on the f-ratio of a system based on the maximum loss allowable for a planned instrument. Our results confirm that hexabundles are a successful alternative for fibre imaging devices for multi-object spectroscopy on wide-field telescopes and have prompted further development of hexabundle designs with hexagonal packing and square cores. Comment: 9 pages, 7 figures. Accepted for publication in MNRAS Text sami ArXiv.org (Cornell University Library) Bryant ENVELOPE(-60.942,-60.942,-71.236,-71.236) Monthly Notices of the Royal Astronomical Society 438 1 869 877
institution Open Polar
collection ArXiv.org (Cornell University Library)
op_collection_id ftarxivpreprints
language unknown
topic Astrophysics - Instrumentation and Methods for Astrophysics
spellingShingle Astrophysics - Instrumentation and Methods for Astrophysics
Bryant, Julia
Bland-Hawthorn, Joss
Fogarty, Lisa
Lawrence, Jon
Croom, Scott
Focal ratio degradation in lightly-fused hexabundles
topic_facet Astrophysics - Instrumentation and Methods for Astrophysics
description We are now moving into an era where multi-object wide-field surveys, which traditionally use single fibres to observe many targets simultaneously, can exploit compact integral field units in place of single fibres. Current multi-object integral field instruments such as SAMI (Croom et al. 2012; Bryant et al. 2012a) have driven the development of new imaging fibre bundles (hexabundles) for multi-object spectrographs. We have characterised the performance of hexabundles with different cladding thicknesses and compared them to that of the same type of bare fibre, across the range of fill-fractions and input f-ratios likely in an IFU instrument. Hexabundles with 7-cores and 61-cores were tested for focal ratio degradation (FRD), throughput and cross-talk when fed with inputs from F/3.4 to >F/8. The five 7-core bundles have cladding thickness ranging from 1 to 8 microns, and the 61-core bundles have 5micron cladding. As expected, the FRD improves as the input focal ratio decreases. We find that the FRD and throughput of the cores in the hexabundles match the performance of single fibres of the same material at low input f-ratios. The performance results presented can be used to set a limit on the f-ratio of a system based on the maximum loss allowable for a planned instrument. Our results confirm that hexabundles are a successful alternative for fibre imaging devices for multi-object spectroscopy on wide-field telescopes and have prompted further development of hexabundle designs with hexagonal packing and square cores. Comment: 9 pages, 7 figures. Accepted for publication in MNRAS
format Text
author Bryant, Julia
Bland-Hawthorn, Joss
Fogarty, Lisa
Lawrence, Jon
Croom, Scott
author_facet Bryant, Julia
Bland-Hawthorn, Joss
Fogarty, Lisa
Lawrence, Jon
Croom, Scott
author_sort Bryant, Julia
title Focal ratio degradation in lightly-fused hexabundles
title_short Focal ratio degradation in lightly-fused hexabundles
title_full Focal ratio degradation in lightly-fused hexabundles
title_fullStr Focal ratio degradation in lightly-fused hexabundles
title_full_unstemmed Focal ratio degradation in lightly-fused hexabundles
title_sort focal ratio degradation in lightly-fused hexabundles
publishDate 2013
url http://arxiv.org/abs/1311.6865
https://doi.org/10.1093/mnras/stt2254
long_lat ENVELOPE(-60.942,-60.942,-71.236,-71.236)
geographic Bryant
geographic_facet Bryant
genre sami
genre_facet sami
op_relation http://arxiv.org/abs/1311.6865
doi:10.1093/mnras/stt2254
op_doi https://doi.org/10.1093/mnras/stt2254
container_title Monthly Notices of the Royal Astronomical Society
container_volume 438
container_issue 1
container_start_page 869
op_container_end_page 877
_version_ 1776203504001482752