Metal concentrations during operation of a Permeable Reactive Barrier containing zero-valent iron.
The data set consists of field solution metal concentrations for a new sequence of material installed within an existing permeable reactive barrier at the Casey Station Main Powerhouse. Three Excel files from ICP analysis are included. 1. The limit of quantification and certified reference material...
Other Authors: | , , , , , |
---|---|
Format: | Dataset |
Language: | unknown |
Published: |
Australian Antarctic Data Centre
|
Subjects: | |
Online Access: | https://researchdata.ands.org.au/metal-concentrations-operation-valent-iron/698959 https://doi.org/10.4225/15/53192062365BD https://data.aad.gov.au/metadata/records/AAS_4029_Field_ICP http://nla.gov.au/nla.party-617536 |
id |
ftands:oai:ands.org.au::698959 |
---|---|
record_format |
openpolar |
spelling |
ftands:oai:ands.org.au::698959 2023-05-15T13:46:57+02:00 Metal concentrations during operation of a Permeable Reactive Barrier containing zero-valent iron. Australian Antarctic Data Centre (publisher) MASON, LACHLAN (processor) MUMFORD, KATHRYN ANNE (hasPrincipalInvestigator) MUMFORD, KATHRYN ANNE (processor) STATHAM, TOM (hasPrincipalInvestigator) STATHAM, TOM (processor) Spatial: northlimit=-66.0; southlimit=-66.0; westlimit=110.0; eastLimit=110.0; projection=WGS84 Temporal: From 2013-01-21 to 2013-02-06 https://researchdata.ands.org.au/metal-concentrations-operation-valent-iron/698959 https://doi.org/10.4225/15/53192062365BD https://data.aad.gov.au/metadata/records/AAS_4029_Field_ICP http://nla.gov.au/nla.party-617536 unknown Australian Antarctic Data Centre https://researchdata.ands.org.au/metal-concentrations-operation-valent-iron/698959 2b3ecc34-4fb6-449e-8471-fdb1c68fe701 doi:10.4225/15/53192062365BD AAS_4029_Field_ICP https://data.aad.gov.au/metadata/records/AAS_4029_Field_ICP http://nla.gov.au/nla.party-617536 Australian Antarctic Data Centre environment CONTAMINANT LEVELS/SPILLS EARTH SCIENCE HUMAN DIMENSIONS ENVIRONMENTAL IMPACTS BUILDINGS INFRASTRUCTURE Permeable Reactive Barrier PRB Casey Contaminants FIELD INVESTIGATION FIELD SURVEYS LABORATORY CONTINENT > ANTARCTICA GEOGRAPHIC REGION > POLAR dataset ftands https://doi.org/10.4225/15/53192062365BD 2020-01-05T21:15:41Z The data set consists of field solution metal concentrations for a new sequence of material installed within an existing permeable reactive barrier at the Casey Station Main Powerhouse. Three Excel files from ICP analysis are included. 1. The limit of quantification and certified reference material results from 2013/14 2. Field sample results from 2012/13 3. Field sample results from 2013/14 The barrier was originally constructed in the 2005/06 summer for details refer to (Mumford et al., 2013). The reactive gate consists of five modified Australian Antarctic Division cage pallets with external dimensions 1.8 x L 1.1 W x 0.75 H m. During the 2012/13 field season, media in the fifth cage was replaced with a new trial media sequence (Statham draft publication). Refilling occurred on the 16th of January. In this process mixed media sequences were homogenised by a cement mixer in 40 L batches and then placed in the PRB cage. Samples for metal concentration analysis collected six times over each of the 2012/13 and 2013/14 summer seasons. Samples were drawn from the lowest unfrozen depth of each multiport in cage 5. To minimise collection interference the procedure started at the most downstream multiport and continued upgradient. From each port two 30 mL samples were drawn, the first was filtered to 0.45 microns, the second was used to measure pH, Eh and EC readings. All samples were acidified (pH less than 2 using nitric acid) and frozen for storage and transport to Australia. Element concentrations and analysed by inductively couple plasma-optical emission spectroscopy (ICP-OES) using a Varian 720-ES spectrometer at the Australian Antarctic Division. The emission intensity of standards and sample solutions was measured following 1:1 in-line mixing with a solution of 0.75% (w/v) CsCl matrix modifier in 10% (v/v) HNO3 containing 5 mg L-1 yttrium as an internal standard. It was deemed unnecessary to use a matrix modifier for the 2014 analysis. Dataset Antarc* Antarctic Antarctica Australian Antarctic Division Research Data Australia (Australian National Data Service - ANDS) Antarctic Casey Station ENVELOPE(110.528,110.528,-66.282,-66.282) Mumford ENVELOPE(-65.123,-65.123,-71.552,-71.552) ENVELOPE(110.0,110.0,-66.0,-66.0) |
institution |
Open Polar |
collection |
Research Data Australia (Australian National Data Service - ANDS) |
op_collection_id |
ftands |
language |
unknown |
topic |
environment CONTAMINANT LEVELS/SPILLS EARTH SCIENCE HUMAN DIMENSIONS ENVIRONMENTAL IMPACTS BUILDINGS INFRASTRUCTURE Permeable Reactive Barrier PRB Casey Contaminants FIELD INVESTIGATION FIELD SURVEYS LABORATORY CONTINENT > ANTARCTICA GEOGRAPHIC REGION > POLAR |
spellingShingle |
environment CONTAMINANT LEVELS/SPILLS EARTH SCIENCE HUMAN DIMENSIONS ENVIRONMENTAL IMPACTS BUILDINGS INFRASTRUCTURE Permeable Reactive Barrier PRB Casey Contaminants FIELD INVESTIGATION FIELD SURVEYS LABORATORY CONTINENT > ANTARCTICA GEOGRAPHIC REGION > POLAR Metal concentrations during operation of a Permeable Reactive Barrier containing zero-valent iron. |
topic_facet |
environment CONTAMINANT LEVELS/SPILLS EARTH SCIENCE HUMAN DIMENSIONS ENVIRONMENTAL IMPACTS BUILDINGS INFRASTRUCTURE Permeable Reactive Barrier PRB Casey Contaminants FIELD INVESTIGATION FIELD SURVEYS LABORATORY CONTINENT > ANTARCTICA GEOGRAPHIC REGION > POLAR |
description |
The data set consists of field solution metal concentrations for a new sequence of material installed within an existing permeable reactive barrier at the Casey Station Main Powerhouse. Three Excel files from ICP analysis are included. 1. The limit of quantification and certified reference material results from 2013/14 2. Field sample results from 2012/13 3. Field sample results from 2013/14 The barrier was originally constructed in the 2005/06 summer for details refer to (Mumford et al., 2013). The reactive gate consists of five modified Australian Antarctic Division cage pallets with external dimensions 1.8 x L 1.1 W x 0.75 H m. During the 2012/13 field season, media in the fifth cage was replaced with a new trial media sequence (Statham draft publication). Refilling occurred on the 16th of January. In this process mixed media sequences were homogenised by a cement mixer in 40 L batches and then placed in the PRB cage. Samples for metal concentration analysis collected six times over each of the 2012/13 and 2013/14 summer seasons. Samples were drawn from the lowest unfrozen depth of each multiport in cage 5. To minimise collection interference the procedure started at the most downstream multiport and continued upgradient. From each port two 30 mL samples were drawn, the first was filtered to 0.45 microns, the second was used to measure pH, Eh and EC readings. All samples were acidified (pH less than 2 using nitric acid) and frozen for storage and transport to Australia. Element concentrations and analysed by inductively couple plasma-optical emission spectroscopy (ICP-OES) using a Varian 720-ES spectrometer at the Australian Antarctic Division. The emission intensity of standards and sample solutions was measured following 1:1 in-line mixing with a solution of 0.75% (w/v) CsCl matrix modifier in 10% (v/v) HNO3 containing 5 mg L-1 yttrium as an internal standard. It was deemed unnecessary to use a matrix modifier for the 2014 analysis. |
author2 |
Australian Antarctic Data Centre (publisher) MASON, LACHLAN (processor) MUMFORD, KATHRYN ANNE (hasPrincipalInvestigator) MUMFORD, KATHRYN ANNE (processor) STATHAM, TOM (hasPrincipalInvestigator) STATHAM, TOM (processor) |
format |
Dataset |
title |
Metal concentrations during operation of a Permeable Reactive Barrier containing zero-valent iron. |
title_short |
Metal concentrations during operation of a Permeable Reactive Barrier containing zero-valent iron. |
title_full |
Metal concentrations during operation of a Permeable Reactive Barrier containing zero-valent iron. |
title_fullStr |
Metal concentrations during operation of a Permeable Reactive Barrier containing zero-valent iron. |
title_full_unstemmed |
Metal concentrations during operation of a Permeable Reactive Barrier containing zero-valent iron. |
title_sort |
metal concentrations during operation of a permeable reactive barrier containing zero-valent iron. |
publisher |
Australian Antarctic Data Centre |
url |
https://researchdata.ands.org.au/metal-concentrations-operation-valent-iron/698959 https://doi.org/10.4225/15/53192062365BD https://data.aad.gov.au/metadata/records/AAS_4029_Field_ICP http://nla.gov.au/nla.party-617536 |
op_coverage |
Spatial: northlimit=-66.0; southlimit=-66.0; westlimit=110.0; eastLimit=110.0; projection=WGS84 Temporal: From 2013-01-21 to 2013-02-06 |
long_lat |
ENVELOPE(110.528,110.528,-66.282,-66.282) ENVELOPE(-65.123,-65.123,-71.552,-71.552) ENVELOPE(110.0,110.0,-66.0,-66.0) |
geographic |
Antarctic Casey Station Mumford |
geographic_facet |
Antarctic Casey Station Mumford |
genre |
Antarc* Antarctic Antarctica Australian Antarctic Division |
genre_facet |
Antarc* Antarctic Antarctica Australian Antarctic Division |
op_source |
Australian Antarctic Data Centre |
op_relation |
https://researchdata.ands.org.au/metal-concentrations-operation-valent-iron/698959 2b3ecc34-4fb6-449e-8471-fdb1c68fe701 doi:10.4225/15/53192062365BD AAS_4029_Field_ICP https://data.aad.gov.au/metadata/records/AAS_4029_Field_ICP http://nla.gov.au/nla.party-617536 |
op_doi |
https://doi.org/10.4225/15/53192062365BD |
_version_ |
1766245788989521920 |