UVSIMN GUV Summit
This data set includes data of a GUV-511 radiometer installed at Summit, Greenland. The system has historically been part of the National Science Foundation's Office of Polar Programs Ultraviolet Spectral Irradiance Monitoring Network (UVSIMN) and is now part of the Arctic Observing Network. Th...
Main Author: | |
---|---|
Format: | Dataset |
Language: | unknown |
Published: |
Arctic Data Center
2009
|
Subjects: | |
Online Access: | https://doi.org/10.18739/A2T60P |
id |
dataone:doi:10.18739/A2T60P |
---|---|
record_format |
openpolar |
spelling |
dataone:doi:10.18739/A2T60P 2024-10-03T18:45:55+00:00 UVSIMN GUV Summit Germar Bernhard NORTH AMERICA > GREENLAND ENVELOPE(-38.455,-38.455,72.579,72.579) BEGINDATE: 2004-08-15T00:00:00Z ENDDATE: 2012-12-19T00:00:00Z 2009-11-18T00:00:00Z https://doi.org/10.18739/A2T60P unknown Arctic Data Center EARTH SCIENCE > ATMOSPHERE > ATMOSPHERIC RADIATION > ULTRAVIOLET RADIATION EARTH REMOTE SENSING INSTRUMENTS > PASSIVE REMOTE SENSING > SPECTROMETERS/RADIOMETERS > RADIOMETERS > RADIOMETERS MANNED PERMANENT STATION POINT 1 MINUTE TO 1 HOUR climatologyMeteorologyAtmosphere Dataset 2009 dataone:urn:node:ARCTIC https://doi.org/10.18739/A2T60P 2024-10-03T18:08:30Z This data set includes data of a GUV-511 radiometer installed at Summit, Greenland. The system has historically been part of the National Science Foundation's Office of Polar Programs Ultraviolet Spectral Irradiance Monitoring Network (UVSIMN) and is now part of the Arctic Observing Network. The instrument measures spectral irradiance at 305, 320, 340, and 380 nm with a bandwidth of approximately 10 nm. It also measures Photosynthetically Active Radiation (PAR). Several secondary data products are calculated from the instrument's irradiance measurements, including spectral integrals (e.g. UV-B or UV-A), UV dose-rates (e.g. erythemal irradiance, the UV Index, DNA damaging UV), and total ozone. Data from the GUV-511 instrument complement measurements of a collocated SUV-100 spectroradiometer. SUV-100 data are more accurate than GUV-511 data, but GUV-511 data a better time resolution and a better short-term (hours to days) stability than SUV-100 data. Additional information can be found at the project's portal http://uv.biospherical.com. Dataset Arctic Greenland Arctic Data Center (via DataONE) Arctic Greenland ENVELOPE(-38.455,-38.455,72.579,72.579) |
institution |
Open Polar |
collection |
Arctic Data Center (via DataONE) |
op_collection_id |
dataone:urn:node:ARCTIC |
language |
unknown |
topic |
EARTH SCIENCE > ATMOSPHERE > ATMOSPHERIC RADIATION > ULTRAVIOLET RADIATION EARTH REMOTE SENSING INSTRUMENTS > PASSIVE REMOTE SENSING > SPECTROMETERS/RADIOMETERS > RADIOMETERS > RADIOMETERS MANNED PERMANENT STATION POINT 1 MINUTE TO 1 HOUR climatologyMeteorologyAtmosphere |
spellingShingle |
EARTH SCIENCE > ATMOSPHERE > ATMOSPHERIC RADIATION > ULTRAVIOLET RADIATION EARTH REMOTE SENSING INSTRUMENTS > PASSIVE REMOTE SENSING > SPECTROMETERS/RADIOMETERS > RADIOMETERS > RADIOMETERS MANNED PERMANENT STATION POINT 1 MINUTE TO 1 HOUR climatologyMeteorologyAtmosphere Germar Bernhard UVSIMN GUV Summit |
topic_facet |
EARTH SCIENCE > ATMOSPHERE > ATMOSPHERIC RADIATION > ULTRAVIOLET RADIATION EARTH REMOTE SENSING INSTRUMENTS > PASSIVE REMOTE SENSING > SPECTROMETERS/RADIOMETERS > RADIOMETERS > RADIOMETERS MANNED PERMANENT STATION POINT 1 MINUTE TO 1 HOUR climatologyMeteorologyAtmosphere |
description |
This data set includes data of a GUV-511 radiometer installed at Summit, Greenland. The system has historically been part of the National Science Foundation's Office of Polar Programs Ultraviolet Spectral Irradiance Monitoring Network (UVSIMN) and is now part of the Arctic Observing Network. The instrument measures spectral irradiance at 305, 320, 340, and 380 nm with a bandwidth of approximately 10 nm. It also measures Photosynthetically Active Radiation (PAR). Several secondary data products are calculated from the instrument's irradiance measurements, including spectral integrals (e.g. UV-B or UV-A), UV dose-rates (e.g. erythemal irradiance, the UV Index, DNA damaging UV), and total ozone. Data from the GUV-511 instrument complement measurements of a collocated SUV-100 spectroradiometer. SUV-100 data are more accurate than GUV-511 data, but GUV-511 data a better time resolution and a better short-term (hours to days) stability than SUV-100 data. Additional information can be found at the project's portal http://uv.biospherical.com. |
format |
Dataset |
author |
Germar Bernhard |
author_facet |
Germar Bernhard |
author_sort |
Germar Bernhard |
title |
UVSIMN GUV Summit |
title_short |
UVSIMN GUV Summit |
title_full |
UVSIMN GUV Summit |
title_fullStr |
UVSIMN GUV Summit |
title_full_unstemmed |
UVSIMN GUV Summit |
title_sort |
uvsimn guv summit |
publisher |
Arctic Data Center |
publishDate |
2009 |
url |
https://doi.org/10.18739/A2T60P |
op_coverage |
NORTH AMERICA > GREENLAND ENVELOPE(-38.455,-38.455,72.579,72.579) BEGINDATE: 2004-08-15T00:00:00Z ENDDATE: 2012-12-19T00:00:00Z |
long_lat |
ENVELOPE(-38.455,-38.455,72.579,72.579) |
geographic |
Arctic Greenland |
geographic_facet |
Arctic Greenland |
genre |
Arctic Greenland |
genre_facet |
Arctic Greenland |
op_doi |
https://doi.org/10.18739/A2T60P |
_version_ |
1811922174951292928 |