AOS: Carbon Monoxide Analyzer - aosco

As of 5 August, 2015, Los Gatos Research (LGR) CO/H2O/N2O analyzer instruments (COANALYZERs) were deployed in the Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF), the third ARM Mobile Facility (AMF3) Aerosol Observing System (AOS), Eastern North Atlantic (ENA) AOS, and Mobile AOS (MAOS...

Full description

Bibliographic Details
Main Author: Stephen Springston
Format: Dataset
Language:unknown
Published: ARM - Atmospheric Radiation Measurement Research Facility 2019
Subjects:
Online Access:https://search.dataone.org/view/b0ff50e6ca62ef8d551ee0b80449339f
id dataone:b0ff50e6ca62ef8d551ee0b80449339f
record_format openpolar
spelling dataone:b0ff50e6ca62ef8d551ee0b80449339f 2024-06-03T18:47:02+00:00 AOS: Carbon Monoxide Analyzer - aosco Stephen Springston ENVELOPE(105.74237,105.74237,87.385956,87.385956) 2019-10-11T00:44:33.729Z https://search.dataone.org/view/b0ff50e6ca62ef8d551ee0b80449339f unknown ARM - Atmospheric Radiation Measurement Research Facility Dataset 2019 dataone:urn:node:ARM 2024-06-03T18:16:46Z As of 5 August, 2015, Los Gatos Research (LGR) CO/H2O/N2O analyzer instruments (COANALYZERs) were deployed in the Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF), the third ARM Mobile Facility (AMF3) Aerosol Observing System (AOS), Eastern North Atlantic (ENA) AOS, and Mobile AOS (MAOS-C). \n \nThe N2O/CO analyzer uses LGR s patented Off-axis ICOS technology, which employs a high-finesse optical cavity as the measurement cell. LGR s technology has many proven advantages over conventional first-generation cavity ringdown spectroscopy (CRDS) techniques. In brief, since the laser beam does not have to be resonantly coupled to the measurement cell, precise beam alignment is not critical. Mentors can disassemble the cell for cleaning (CAREFULLY) the front surface mirrors. Analyzers are relatively inexpensive and inherently robust thermally and mechanically. In addition, since LGR s technology can record reliable absorption spectra over a far wider range of optical depths (absorbance values) than CRDS, LGR analyzers provide measurements over a much wider range of mixing ratios (gas concentrations). The N2O/CO analyzer includes an internal computer that sends real-time data to the local instrument computer through its digital (RS-232) output. Dataset North Atlantic ARM - Atmospheric Radiation Measurement Research Facility (via DataONE) ENVELOPE(105.74237,105.74237,87.385956,87.385956)
institution Open Polar
collection ARM - Atmospheric Radiation Measurement Research Facility (via DataONE)
op_collection_id dataone:urn:node:ARM
language unknown
description As of 5 August, 2015, Los Gatos Research (LGR) CO/H2O/N2O analyzer instruments (COANALYZERs) were deployed in the Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF), the third ARM Mobile Facility (AMF3) Aerosol Observing System (AOS), Eastern North Atlantic (ENA) AOS, and Mobile AOS (MAOS-C). \n \nThe N2O/CO analyzer uses LGR s patented Off-axis ICOS technology, which employs a high-finesse optical cavity as the measurement cell. LGR s technology has many proven advantages over conventional first-generation cavity ringdown spectroscopy (CRDS) techniques. In brief, since the laser beam does not have to be resonantly coupled to the measurement cell, precise beam alignment is not critical. Mentors can disassemble the cell for cleaning (CAREFULLY) the front surface mirrors. Analyzers are relatively inexpensive and inherently robust thermally and mechanically. In addition, since LGR s technology can record reliable absorption spectra over a far wider range of optical depths (absorbance values) than CRDS, LGR analyzers provide measurements over a much wider range of mixing ratios (gas concentrations). The N2O/CO analyzer includes an internal computer that sends real-time data to the local instrument computer through its digital (RS-232) output.
format Dataset
author Stephen Springston
spellingShingle Stephen Springston
AOS: Carbon Monoxide Analyzer - aosco
author_facet Stephen Springston
author_sort Stephen Springston
title AOS: Carbon Monoxide Analyzer - aosco
title_short AOS: Carbon Monoxide Analyzer - aosco
title_full AOS: Carbon Monoxide Analyzer - aosco
title_fullStr AOS: Carbon Monoxide Analyzer - aosco
title_full_unstemmed AOS: Carbon Monoxide Analyzer - aosco
title_sort aos: carbon monoxide analyzer - aosco
publisher ARM - Atmospheric Radiation Measurement Research Facility
publishDate 2019
url https://search.dataone.org/view/b0ff50e6ca62ef8d551ee0b80449339f
op_coverage ENVELOPE(105.74237,105.74237,87.385956,87.385956)
long_lat ENVELOPE(105.74237,105.74237,87.385956,87.385956)
genre North Atlantic
genre_facet North Atlantic
_version_ 1800874900728053760