SU‐FF‐T‐76: Analysis of a Novel Method of IMRT QA Using EPID‐Acquired QA Planes

Purpose: To assess the efficacy and quantify the accuracy of a novel method for IMRT QA in which the measured dose plane is derived from an EPID image. Method and Materials: aSi EPID data was acquired and converted using a novel method based on a machine‐specific beam model to estimate QA dose plane...

Full description

Bibliographic Details
Published in:Medical Physics
Main Authors: Rasmussen, K, Nelms, B, Tome, W
Format: Article in Journal/Newspaper
Language:English
Published: Wiley 2007
Subjects:
Online Access:http://dx.doi.org/10.1118/1.2760727
https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1118%2F1.2760727
https://onlinelibrary.wiley.com/doi/full/10.1118/1.2760727
id crwiley:10.1118/1.2760727
record_format openpolar
spelling crwiley:10.1118/1.2760727 2023-12-03T10:20:55+01:00 SU‐FF‐T‐76: Analysis of a Novel Method of IMRT QA Using EPID‐Acquired QA Planes Rasmussen, K Nelms, B Tome, W 2007 http://dx.doi.org/10.1118/1.2760727 https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1118%2F1.2760727 https://onlinelibrary.wiley.com/doi/full/10.1118/1.2760727 en eng Wiley http://onlinelibrary.wiley.com/termsAndConditions#vor Medical Physics volume 34, issue 6Part8, page 2418-2418 ISSN 0094-2405 2473-4209 General Medicine journal-article 2007 crwiley https://doi.org/10.1118/1.2760727 2023-11-09T13:13:16Z Purpose: To assess the efficacy and quantify the accuracy of a novel method for IMRT QA in which the measured dose plane is derived from an EPID image. Method and Materials: aSi EPID data was acquired and converted using a novel method based on a machine‐specific beam model to estimate QA dose planes from mega voltage (MV) EPID images. Dose planes were calculated in a homogeneous, water‐equivalent QA phantom using the model and an acquired MV EPID image with no additional buildup required on the EPID. Specific parameters, such as field size output dependency, dose redistribution kernel, potential off‐axis corrections and absolute dose calibration, were measured to create the model that is based on the raw EPID files. QA dose planes were compared to ion chamber measurements, MapCHECK® measurements, and planar fluences generated by ADAC Pinnacle 3 ® TPS. MapCHECK® and ion chamber (IC) measurements were taken at multiple depths at a source to detector distance (SDD) of 100cm. Dose planes in homogenous media were estimated using EPID images acquired at a distance of 140cm SDD. Data was collected for both 6 MV and 10 MV energies to determine the accuracy of the model for these two energies. Results: Preliminary sample analysis demonstrates that the dose planes estimated by the model using EPID images of complex IMRT fields result in >98% pass rate of all point measurements from MapCHECK®, employing a 3% dose or a 2mm distance to agreement criterion. Agreement between MapCHECK® and IC measurements were within 1%. Conclusion: This novel method shows promise as a tool for IMRT QA with reasonable accuracy. Setup, acquisition and analysis can be performed in a more time efficient manner than is possible with current methods of IMRT QA. Conflict of Interest: This work was partially funded by Sun‐Nuclear Co.® and Canis Lupus LLC. Article in Journal/Newspaper Canis lupus Wiley Online Library (via Crossref) Pinnacle ENVELOPE(-54.900,-54.900,-61.067,-61.067) Medical Physics 34 6Part8 2418 2418
institution Open Polar
collection Wiley Online Library (via Crossref)
op_collection_id crwiley
language English
topic General Medicine
spellingShingle General Medicine
Rasmussen, K
Nelms, B
Tome, W
SU‐FF‐T‐76: Analysis of a Novel Method of IMRT QA Using EPID‐Acquired QA Planes
topic_facet General Medicine
description Purpose: To assess the efficacy and quantify the accuracy of a novel method for IMRT QA in which the measured dose plane is derived from an EPID image. Method and Materials: aSi EPID data was acquired and converted using a novel method based on a machine‐specific beam model to estimate QA dose planes from mega voltage (MV) EPID images. Dose planes were calculated in a homogeneous, water‐equivalent QA phantom using the model and an acquired MV EPID image with no additional buildup required on the EPID. Specific parameters, such as field size output dependency, dose redistribution kernel, potential off‐axis corrections and absolute dose calibration, were measured to create the model that is based on the raw EPID files. QA dose planes were compared to ion chamber measurements, MapCHECK® measurements, and planar fluences generated by ADAC Pinnacle 3 ® TPS. MapCHECK® and ion chamber (IC) measurements were taken at multiple depths at a source to detector distance (SDD) of 100cm. Dose planes in homogenous media were estimated using EPID images acquired at a distance of 140cm SDD. Data was collected for both 6 MV and 10 MV energies to determine the accuracy of the model for these two energies. Results: Preliminary sample analysis demonstrates that the dose planes estimated by the model using EPID images of complex IMRT fields result in >98% pass rate of all point measurements from MapCHECK®, employing a 3% dose or a 2mm distance to agreement criterion. Agreement between MapCHECK® and IC measurements were within 1%. Conclusion: This novel method shows promise as a tool for IMRT QA with reasonable accuracy. Setup, acquisition and analysis can be performed in a more time efficient manner than is possible with current methods of IMRT QA. Conflict of Interest: This work was partially funded by Sun‐Nuclear Co.® and Canis Lupus LLC.
format Article in Journal/Newspaper
author Rasmussen, K
Nelms, B
Tome, W
author_facet Rasmussen, K
Nelms, B
Tome, W
author_sort Rasmussen, K
title SU‐FF‐T‐76: Analysis of a Novel Method of IMRT QA Using EPID‐Acquired QA Planes
title_short SU‐FF‐T‐76: Analysis of a Novel Method of IMRT QA Using EPID‐Acquired QA Planes
title_full SU‐FF‐T‐76: Analysis of a Novel Method of IMRT QA Using EPID‐Acquired QA Planes
title_fullStr SU‐FF‐T‐76: Analysis of a Novel Method of IMRT QA Using EPID‐Acquired QA Planes
title_full_unstemmed SU‐FF‐T‐76: Analysis of a Novel Method of IMRT QA Using EPID‐Acquired QA Planes
title_sort su‐ff‐t‐76: analysis of a novel method of imrt qa using epid‐acquired qa planes
publisher Wiley
publishDate 2007
url http://dx.doi.org/10.1118/1.2760727
https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1118%2F1.2760727
https://onlinelibrary.wiley.com/doi/full/10.1118/1.2760727
long_lat ENVELOPE(-54.900,-54.900,-61.067,-61.067)
geographic Pinnacle
geographic_facet Pinnacle
genre Canis lupus
genre_facet Canis lupus
op_source Medical Physics
volume 34, issue 6Part8, page 2418-2418
ISSN 0094-2405 2473-4209
op_rights http://onlinelibrary.wiley.com/termsAndConditions#vor
op_doi https://doi.org/10.1118/1.2760727
container_title Medical Physics
container_volume 34
container_issue 6Part8
container_start_page 2418
op_container_end_page 2418
_version_ 1784268441550585856