Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation

Abstract Background Optimal pulmonary vein (PV) occlusion, usually verified with selective contrast injection, is mandatory to obtain an effective PV isolation during cryoballoon (CB) ablation. Aim of the study The purpose of this study was to verify the feasibility and the accuracy of a new dielect...

Full description

Bibliographic Details
Published in:Pacing and Clinical Electrophysiology
Main Authors: Cauti, Filippo Maria, Solimene, Francesco, Stabile, Giuseppe, Polselli, Marco, Schillaci, Vincenzo, Arestia, Alberto, Shopova, Gergana, Iaia, Luigi, Giannitti, Carlo Maria, Rossi, Pietro, Bianchi, Stefano
Format: Article in Journal/Newspaper
Language:English
Published: Wiley 2020
Subjects:
Online Access:http://dx.doi.org/10.1111/pace.14130
https://onlinelibrary.wiley.com/doi/pdf/10.1111/pace.14130
https://onlinelibrary.wiley.com/doi/full-xml/10.1111/pace.14130
id crwiley:10.1111/pace.14130
record_format openpolar
spelling crwiley:10.1111/pace.14130 2023-12-03T10:18:14+01:00 Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation Cauti, Filippo Maria Solimene, Francesco Stabile, Giuseppe Polselli, Marco Schillaci, Vincenzo Arestia, Alberto Shopova, Gergana Iaia, Luigi Giannitti, Carlo Maria Rossi, Pietro Bianchi, Stefano 2020 http://dx.doi.org/10.1111/pace.14130 https://onlinelibrary.wiley.com/doi/pdf/10.1111/pace.14130 https://onlinelibrary.wiley.com/doi/full-xml/10.1111/pace.14130 en eng Wiley http://onlinelibrary.wiley.com/termsAndConditions#vor Pacing and Clinical Electrophysiology volume 44, issue 1, page 63-70 ISSN 0147-8389 1540-8159 Cardiology and Cardiovascular Medicine General Medicine journal-article 2020 crwiley https://doi.org/10.1111/pace.14130 2023-11-09T13:24:01Z Abstract Background Optimal pulmonary vein (PV) occlusion, usually verified with selective contrast injection, is mandatory to obtain an effective PV isolation during cryoballoon (CB) ablation. Aim of the study The purpose of this study was to verify the feasibility and the accuracy of a new dielectric sensing system in assessing PV occlusion during CB ablation in patients with atrial fibrillation (AF). Methods We enrolled 28 consecutive patients with paroxysmal or persistent AF. After transseptal access, a detailed image reconstruction of left atrium and PVs was achieved with an octapolar or decapolar mapping catheter (Achieve catheter, Medtronic Inc.) and KODEX‐EPD system (EPD Solutions, a Philips company). The degree of PV occlusion with the inflated Arctic Front Advance Cryoballoon (Medtronic Inc.) was verified using the new “occlusion tool” software module (EPD Solutions, a Philips company) and compared to an angiogram obtained with contrast medium injection in each PV. Results A total of 105 PV CB occlusion were tested. The new occlusion tool software module showed a 91% sensitivity and 76% specificity in assessing a complete PV occlusion verified with contrast medium injection. The positive predictive value was 80%, and the negative predictive value was 88.6%. Mean procedure time was 81 ± 17 minutes. Mean fluoroscopy time was 6 ± 2 minutes. No 30‐day complications were observed. Conclusion The new dielectric imaging system was able to assess the degree of PV occlusion during a CB ablation with good sensitivity and specificity. Article in Journal/Newspaper Arctic Wiley Online Library (via Crossref) Arctic Pacing and Clinical Electrophysiology 44 1 63 70
institution Open Polar
collection Wiley Online Library (via Crossref)
op_collection_id crwiley
language English
topic Cardiology and Cardiovascular Medicine
General Medicine
spellingShingle Cardiology and Cardiovascular Medicine
General Medicine
Cauti, Filippo Maria
Solimene, Francesco
Stabile, Giuseppe
Polselli, Marco
Schillaci, Vincenzo
Arestia, Alberto
Shopova, Gergana
Iaia, Luigi
Giannitti, Carlo Maria
Rossi, Pietro
Bianchi, Stefano
Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation
topic_facet Cardiology and Cardiovascular Medicine
General Medicine
description Abstract Background Optimal pulmonary vein (PV) occlusion, usually verified with selective contrast injection, is mandatory to obtain an effective PV isolation during cryoballoon (CB) ablation. Aim of the study The purpose of this study was to verify the feasibility and the accuracy of a new dielectric sensing system in assessing PV occlusion during CB ablation in patients with atrial fibrillation (AF). Methods We enrolled 28 consecutive patients with paroxysmal or persistent AF. After transseptal access, a detailed image reconstruction of left atrium and PVs was achieved with an octapolar or decapolar mapping catheter (Achieve catheter, Medtronic Inc.) and KODEX‐EPD system (EPD Solutions, a Philips company). The degree of PV occlusion with the inflated Arctic Front Advance Cryoballoon (Medtronic Inc.) was verified using the new “occlusion tool” software module (EPD Solutions, a Philips company) and compared to an angiogram obtained with contrast medium injection in each PV. Results A total of 105 PV CB occlusion were tested. The new occlusion tool software module showed a 91% sensitivity and 76% specificity in assessing a complete PV occlusion verified with contrast medium injection. The positive predictive value was 80%, and the negative predictive value was 88.6%. Mean procedure time was 81 ± 17 minutes. Mean fluoroscopy time was 6 ± 2 minutes. No 30‐day complications were observed. Conclusion The new dielectric imaging system was able to assess the degree of PV occlusion during a CB ablation with good sensitivity and specificity.
format Article in Journal/Newspaper
author Cauti, Filippo Maria
Solimene, Francesco
Stabile, Giuseppe
Polselli, Marco
Schillaci, Vincenzo
Arestia, Alberto
Shopova, Gergana
Iaia, Luigi
Giannitti, Carlo Maria
Rossi, Pietro
Bianchi, Stefano
author_facet Cauti, Filippo Maria
Solimene, Francesco
Stabile, Giuseppe
Polselli, Marco
Schillaci, Vincenzo
Arestia, Alberto
Shopova, Gergana
Iaia, Luigi
Giannitti, Carlo Maria
Rossi, Pietro
Bianchi, Stefano
author_sort Cauti, Filippo Maria
title Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation
title_short Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation
title_full Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation
title_fullStr Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation
title_full_unstemmed Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation
title_sort occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation
publisher Wiley
publishDate 2020
url http://dx.doi.org/10.1111/pace.14130
https://onlinelibrary.wiley.com/doi/pdf/10.1111/pace.14130
https://onlinelibrary.wiley.com/doi/full-xml/10.1111/pace.14130
geographic Arctic
geographic_facet Arctic
genre Arctic
genre_facet Arctic
op_source Pacing and Clinical Electrophysiology
volume 44, issue 1, page 63-70
ISSN 0147-8389 1540-8159
op_rights http://onlinelibrary.wiley.com/termsAndConditions#vor
op_doi https://doi.org/10.1111/pace.14130
container_title Pacing and Clinical Electrophysiology
container_volume 44
container_issue 1
container_start_page 63
op_container_end_page 70
_version_ 1784265222395002880