Retinal Oximetry

Abstract. Purpose: Malfunction of retinal blood flow or oxygenation is believed to be involved in various diseases. Among them are retinal vessel occlusions, diabetic retinopathy and glaucoma. Reliable, non‐invasive technology for retinal oxygen measurements has been scarce and most of the knowledge...

Full description

Bibliographic Details
Published in:Acta Ophthalmologica
Main Author: Hardarson, Sveinn Hakon
Format: Article in Journal/Newspaper
Language:English
Published: Wiley 2013
Subjects:
Online Access:http://dx.doi.org/10.1111/aos.12086
https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1111%2Faos.12086
https://onlinelibrary.wiley.com/doi/pdf/10.1111/aos.12086
id crwiley:10.1111/aos.12086
record_format openpolar
spelling crwiley:10.1111/aos.12086 2024-06-23T07:54:07+00:00 Retinal Oximetry Hardarson, Sveinn Hakon 2013 http://dx.doi.org/10.1111/aos.12086 https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1111%2Faos.12086 https://onlinelibrary.wiley.com/doi/pdf/10.1111/aos.12086 en eng Wiley http://onlinelibrary.wiley.com/termsAndConditions#vor Acta Ophthalmologica volume 91, issue thesis2, page 1-47 ISSN 1755-375X 1755-3768 journal-article 2013 crwiley https://doi.org/10.1111/aos.12086 2024-06-11T04:49:20Z Abstract. Purpose: Malfunction of retinal blood flow or oxygenation is believed to be involved in various diseases. Among them are retinal vessel occlusions, diabetic retinopathy and glaucoma. Reliable, non‐invasive technology for retinal oxygen measurements has been scarce and most of the knowledge on retinal oxygenation comes from animal studies. This thesis describes human retinal oximetry, performed with novel retinal oximetry technology. The thesis describes studies on retinal vessel oxygen saturation in (1) light and dark in healthy volunteers, (2) central retinal vein occlusion, (3) branch retinal vein occlusion, (4) central retinal artery occlusion, (5) diabetic retinopathy, (6) patients undergoing glaucoma surgery and (7) patients taking glaucoma medication. Methods: The retinal oximeter (Oxymap ehf., Reykjavik, Iceland) is based on a fundus camera. An attached image splitter allows the simultaneous capture of four images of the same area of the fundus. Two images are used for further analysis, one acquired with 586 nm light and one with 605 nm light. Light absorbance of retinal vessels is sensitive to oxygen saturation at 605 nm but not at 586 nm. Measurement of reflected light at these wavelengths allows estimation of oxygen saturation in the main retinal vessels. This is performed with custom‐made analysis software. Results Light and dark After 30 min in the dark, oxygen saturation in retinal arterioles of healthy volunteers was 92 ± 4% (mean ± SD, n = 15). After 5 min in 80 cd/m 2 light, the arteriolar saturation was 89 ± 5%. The decrease was statistically significant (p = 0.008). The corresponding values for retinal venules were 60 ± 5% in the dark and 55 ± 10% in the light (p = 0.020). Similar results were found after alternating 5 min periods of darkness and light. In a second experiment ( n = 19), a significant decrease in retinal vessel oxygen saturation was found in 100 cd/m 2 light compared with darkness but 1 and 10 cd/m 2 light had no significant effect. Central retinal vein occlusion In ... Article in Journal/Newspaper Iceland Wiley Online Library Acta Ophthalmologica 91 thesis2 1 47
institution Open Polar
collection Wiley Online Library
op_collection_id crwiley
language English
description Abstract. Purpose: Malfunction of retinal blood flow or oxygenation is believed to be involved in various diseases. Among them are retinal vessel occlusions, diabetic retinopathy and glaucoma. Reliable, non‐invasive technology for retinal oxygen measurements has been scarce and most of the knowledge on retinal oxygenation comes from animal studies. This thesis describes human retinal oximetry, performed with novel retinal oximetry technology. The thesis describes studies on retinal vessel oxygen saturation in (1) light and dark in healthy volunteers, (2) central retinal vein occlusion, (3) branch retinal vein occlusion, (4) central retinal artery occlusion, (5) diabetic retinopathy, (6) patients undergoing glaucoma surgery and (7) patients taking glaucoma medication. Methods: The retinal oximeter (Oxymap ehf., Reykjavik, Iceland) is based on a fundus camera. An attached image splitter allows the simultaneous capture of four images of the same area of the fundus. Two images are used for further analysis, one acquired with 586 nm light and one with 605 nm light. Light absorbance of retinal vessels is sensitive to oxygen saturation at 605 nm but not at 586 nm. Measurement of reflected light at these wavelengths allows estimation of oxygen saturation in the main retinal vessels. This is performed with custom‐made analysis software. Results Light and dark After 30 min in the dark, oxygen saturation in retinal arterioles of healthy volunteers was 92 ± 4% (mean ± SD, n = 15). After 5 min in 80 cd/m 2 light, the arteriolar saturation was 89 ± 5%. The decrease was statistically significant (p = 0.008). The corresponding values for retinal venules were 60 ± 5% in the dark and 55 ± 10% in the light (p = 0.020). Similar results were found after alternating 5 min periods of darkness and light. In a second experiment ( n = 19), a significant decrease in retinal vessel oxygen saturation was found in 100 cd/m 2 light compared with darkness but 1 and 10 cd/m 2 light had no significant effect. Central retinal vein occlusion In ...
format Article in Journal/Newspaper
author Hardarson, Sveinn Hakon
spellingShingle Hardarson, Sveinn Hakon
Retinal Oximetry
author_facet Hardarson, Sveinn Hakon
author_sort Hardarson, Sveinn Hakon
title Retinal Oximetry
title_short Retinal Oximetry
title_full Retinal Oximetry
title_fullStr Retinal Oximetry
title_full_unstemmed Retinal Oximetry
title_sort retinal oximetry
publisher Wiley
publishDate 2013
url http://dx.doi.org/10.1111/aos.12086
https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1111%2Faos.12086
https://onlinelibrary.wiley.com/doi/pdf/10.1111/aos.12086
genre Iceland
genre_facet Iceland
op_source Acta Ophthalmologica
volume 91, issue thesis2, page 1-47
ISSN 1755-375X 1755-3768
op_rights http://onlinelibrary.wiley.com/termsAndConditions#vor
op_doi https://doi.org/10.1111/aos.12086
container_title Acta Ophthalmologica
container_volume 91
container_issue thesis2
container_start_page 1
op_container_end_page 47
_version_ 1802646088622014464