Simplified method for microlitre deuterium measurements in water and urine by gas chromatography–high‐temperature conversion–isotope ratio mass spectrometry

Abstract Deuterium ( 2 H) in water and urine can be measured by off‐line and, more recently, on‐line techniques using isotope ratio mass spectrometry (IRMS). We describe a new simple on‐line pyrolysis method for the analysis of 2 H/ 1 H in water and urine samples by continuous flow IRMS, normally us...

Full description

Bibliographic Details
Published in:Rapid Communications in Mass Spectrometry
Main Authors: Gucciardi, Antonina, Cogo, Paola E., Traldi, Umberto, Eaton, Simon, Darch, Tegan, Simonato, Manuela, Ori, Carlo, Carnielli, Virgilio P.
Format: Article in Journal/Newspaper
Language:English
Published: Wiley 2008
Subjects:
Online Access:http://dx.doi.org/10.1002/rcm.3593
https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1002%2Frcm.3593
http://onlinelibrary.wiley.com/wol1/doi/10.1002/rcm.3593/fullpdf
id crwiley:10.1002/rcm.3593
record_format openpolar
spelling crwiley:10.1002/rcm.3593 2024-06-02T07:57:39+00:00 Simplified method for microlitre deuterium measurements in water and urine by gas chromatography–high‐temperature conversion–isotope ratio mass spectrometry Gucciardi, Antonina Cogo, Paola E. Traldi, Umberto Eaton, Simon Darch, Tegan Simonato, Manuela Ori, Carlo Carnielli, Virgilio P. 2008 http://dx.doi.org/10.1002/rcm.3593 https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1002%2Frcm.3593 http://onlinelibrary.wiley.com/wol1/doi/10.1002/rcm.3593/fullpdf en eng Wiley http://onlinelibrary.wiley.com/termsAndConditions#vor Rapid Communications in Mass Spectrometry volume 22, issue 13, page 2097-2103 ISSN 0951-4198 1097-0231 journal-article 2008 crwiley https://doi.org/10.1002/rcm.3593 2024-05-03T10:40:05Z Abstract Deuterium ( 2 H) in water and urine can be measured by off‐line and, more recently, on‐line techniques using isotope ratio mass spectrometry (IRMS). We describe a new simple on‐line pyrolysis method for the analysis of 2 H/ 1 H in water and urine samples by continuous flow IRMS, normally used for 2 H/ 1 H measurements in organic compounds. A deactivated column connected the split injector to a high‐temperature conversion reactor (TC HD), and 0.5 µL of sample was injected. Accuracy and precision were determined with Vienna Standard Mean Ocean Water (VSMOW), Standard Light Antarctic Precipitation (SLAP), and Greenland Ice Sheet Precipitation (GISP). The range of linearity was measured with a calibration curve of enriched water from 0 up to 0.1 atom percent excess (APE) (i.e. −72 up to 6323 delta per mil ( δ D ‰)) with a precision of <5‰ and accuracy ranging between 1 and 55‰. Blinded reanalysis of urine samples by an equilibration device (Gas Bench) and by a dedicated pyrolysis system (TC/EA) was performed and results compared by the Bland‐Altman test. Enrichments ranged between 600 and 2400‰ δD VSMOW with a precision of ±5‰. Urine enrichments described by our method were strongly correlated with values obtained by Gas Bench and TC/EA ( p < 0.0001). There was a significant memory effect that was reduced by injecting the sample 15 times and discarding the first 10 injections, together with accurate furnace conditioning and appropriate cleaning of the syringe. Data indicate that the method is accurate, and that it can be used for water and urine deuterium determination when a Gas Bench or TC/EA instrument is not available and the amount of sample is limited. Copyright © 2008 John Wiley & Sons, Ltd. Article in Journal/Newspaper Antarc* Antarctic GISP Greenland Ice Sheet Wiley Online Library Antarctic Greenland Rapid Communications in Mass Spectrometry 22 13 2097 2103
institution Open Polar
collection Wiley Online Library
op_collection_id crwiley
language English
description Abstract Deuterium ( 2 H) in water and urine can be measured by off‐line and, more recently, on‐line techniques using isotope ratio mass spectrometry (IRMS). We describe a new simple on‐line pyrolysis method for the analysis of 2 H/ 1 H in water and urine samples by continuous flow IRMS, normally used for 2 H/ 1 H measurements in organic compounds. A deactivated column connected the split injector to a high‐temperature conversion reactor (TC HD), and 0.5 µL of sample was injected. Accuracy and precision were determined with Vienna Standard Mean Ocean Water (VSMOW), Standard Light Antarctic Precipitation (SLAP), and Greenland Ice Sheet Precipitation (GISP). The range of linearity was measured with a calibration curve of enriched water from 0 up to 0.1 atom percent excess (APE) (i.e. −72 up to 6323 delta per mil ( δ D ‰)) with a precision of <5‰ and accuracy ranging between 1 and 55‰. Blinded reanalysis of urine samples by an equilibration device (Gas Bench) and by a dedicated pyrolysis system (TC/EA) was performed and results compared by the Bland‐Altman test. Enrichments ranged between 600 and 2400‰ δD VSMOW with a precision of ±5‰. Urine enrichments described by our method were strongly correlated with values obtained by Gas Bench and TC/EA ( p < 0.0001). There was a significant memory effect that was reduced by injecting the sample 15 times and discarding the first 10 injections, together with accurate furnace conditioning and appropriate cleaning of the syringe. Data indicate that the method is accurate, and that it can be used for water and urine deuterium determination when a Gas Bench or TC/EA instrument is not available and the amount of sample is limited. Copyright © 2008 John Wiley & Sons, Ltd.
format Article in Journal/Newspaper
author Gucciardi, Antonina
Cogo, Paola E.
Traldi, Umberto
Eaton, Simon
Darch, Tegan
Simonato, Manuela
Ori, Carlo
Carnielli, Virgilio P.
spellingShingle Gucciardi, Antonina
Cogo, Paola E.
Traldi, Umberto
Eaton, Simon
Darch, Tegan
Simonato, Manuela
Ori, Carlo
Carnielli, Virgilio P.
Simplified method for microlitre deuterium measurements in water and urine by gas chromatography–high‐temperature conversion–isotope ratio mass spectrometry
author_facet Gucciardi, Antonina
Cogo, Paola E.
Traldi, Umberto
Eaton, Simon
Darch, Tegan
Simonato, Manuela
Ori, Carlo
Carnielli, Virgilio P.
author_sort Gucciardi, Antonina
title Simplified method for microlitre deuterium measurements in water and urine by gas chromatography–high‐temperature conversion–isotope ratio mass spectrometry
title_short Simplified method for microlitre deuterium measurements in water and urine by gas chromatography–high‐temperature conversion–isotope ratio mass spectrometry
title_full Simplified method for microlitre deuterium measurements in water and urine by gas chromatography–high‐temperature conversion–isotope ratio mass spectrometry
title_fullStr Simplified method for microlitre deuterium measurements in water and urine by gas chromatography–high‐temperature conversion–isotope ratio mass spectrometry
title_full_unstemmed Simplified method for microlitre deuterium measurements in water and urine by gas chromatography–high‐temperature conversion–isotope ratio mass spectrometry
title_sort simplified method for microlitre deuterium measurements in water and urine by gas chromatography–high‐temperature conversion–isotope ratio mass spectrometry
publisher Wiley
publishDate 2008
url http://dx.doi.org/10.1002/rcm.3593
https://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1002%2Frcm.3593
http://onlinelibrary.wiley.com/wol1/doi/10.1002/rcm.3593/fullpdf
geographic Antarctic
Greenland
geographic_facet Antarctic
Greenland
genre Antarc*
Antarctic
GISP
Greenland
Ice Sheet
genre_facet Antarc*
Antarctic
GISP
Greenland
Ice Sheet
op_source Rapid Communications in Mass Spectrometry
volume 22, issue 13, page 2097-2103
ISSN 0951-4198 1097-0231
op_rights http://onlinelibrary.wiley.com/termsAndConditions#vor
op_doi https://doi.org/10.1002/rcm.3593
container_title Rapid Communications in Mass Spectrometry
container_volume 22
container_issue 13
container_start_page 2097
op_container_end_page 2103
_version_ 1800740837263409152