O009 Are there Differences in SpO2 Recordings from Two Oximeters on the same hand during an Overnight Sleep Study Significant?

Abstract Background Accurate non-invasive oxygen saturation (SpO2) measurement is crucial in healthcare, however is challenged by numerous devices using variable algorithms1. We compared two commonly used oximeter devices worn simultaneously in patients during an overnight polysomnogram. Aim To asse...

Full description

Bibliographic Details
Published in:Sleep Advances
Main Authors: McDermott, E, Cuesta, R, van Braak, E, Spiteri, M, Davis, S, Beranek, R, Kaur-Bains, S, Slater, B, Naughton, M, Roebuck, T, Nguy, R
Format: Article in Journal/Newspaper
Language:English
Published: Oxford University Press (OUP) 2023
Subjects:
Online Access:http://dx.doi.org/10.1093/sleepadvances/zpad035.009
https://academic.oup.com/sleepadvances/article-pdf/4/Supplement_1/A3/52405572/zpad035.009.pdf
id croxfordunivpr:10.1093/sleepadvances/zpad035.009
record_format openpolar
spelling croxfordunivpr:10.1093/sleepadvances/zpad035.009 2023-12-31T10:08:24+01:00 O009 Are there Differences in SpO2 Recordings from Two Oximeters on the same hand during an Overnight Sleep Study Significant? McDermott, E Cuesta, R van Braak, E Spiteri, M Davis, S Beranek, R Kaur-Bains, S Slater, B Naughton, M Roebuck, T Nguy, R 2023 http://dx.doi.org/10.1093/sleepadvances/zpad035.009 https://academic.oup.com/sleepadvances/article-pdf/4/Supplement_1/A3/52405572/zpad035.009.pdf en eng Oxford University Press (OUP) https://creativecommons.org/licenses/by-nc-nd/4.0/ Sleep Advances volume 4, issue Supplement_1, page A3-A4 ISSN 2632-5012 General Medicine journal-article 2023 croxfordunivpr https://doi.org/10.1093/sleepadvances/zpad035.009 2023-12-06T09:07:51Z Abstract Background Accurate non-invasive oxygen saturation (SpO2) measurement is crucial in healthcare, however is challenged by numerous devices using variable algorithms1. We compared two commonly used oximeter devices worn simultaneously in patients during an overnight polysomnogram. Aim To assess (1) differences between two SpO2 recording devices and (2) SpO2 accuracy against SaO2. Methods SpO2 data of two devices were recorded, downloaded and analysed with corresponding software: device 1 (Rad7 [Masimo, Irvine, CA, USA] set at 2-4sec averaging time) with software 1 (PSG 4 [Compumedics, Melbourne, Australia]) and device 2 (Wrist-Ox2® [Nonin Medical Inc, Plymouth, MN, USA] set at 3 sec averaging time) with software 2 (Noxturnal [Nox Medical Inc, Reykjavik, Iceland]). Responsiveness of each oximeter to changes in the patients’ desaturations associated with apnoeas and hypopnoeas overnight was assessed. In addition, both device SpO2 values were compared with SaO2 from simultaneous arterial blood gas sampling. Preliminary Results 7 patients (age 56.4±7.1 years, BMI 31.6±2.2 kg/m2, 100% male, 87% light skinned) were studied. The mean SpO2 with RAD7 was higher than the Nonin (95.9±1.6 vs 94.2±1.4%, mean difference 1.6±1.0%). Differences in the responsiveness of the oximeters during overnight desaturations were also observed. However, both device SpO2 values were found to be within ±2% of SaO2. Conclusions Discrepancies in SpO2 measurement do occur between devices and may have important clinical implications especially when it comes to the measurement of hypoxemic burden during sleep. 1.Blanchet MA et al. Accuracy of Multiple Pulse Oximeters in Stable Critically Ill Patients. Respir Care. 2023 May;68(5):565-574. Article in Journal/Newspaper Iceland Oxford University Press (via Crossref) Sleep Advances 4 Supplement_1 A3 A4
institution Open Polar
collection Oxford University Press (via Crossref)
op_collection_id croxfordunivpr
language English
topic General Medicine
spellingShingle General Medicine
McDermott, E
Cuesta, R
van Braak, E
Spiteri, M
Davis, S
Beranek, R
Kaur-Bains, S
Slater, B
Naughton, M
Roebuck, T
Nguy, R
O009 Are there Differences in SpO2 Recordings from Two Oximeters on the same hand during an Overnight Sleep Study Significant?
topic_facet General Medicine
description Abstract Background Accurate non-invasive oxygen saturation (SpO2) measurement is crucial in healthcare, however is challenged by numerous devices using variable algorithms1. We compared two commonly used oximeter devices worn simultaneously in patients during an overnight polysomnogram. Aim To assess (1) differences between two SpO2 recording devices and (2) SpO2 accuracy against SaO2. Methods SpO2 data of two devices were recorded, downloaded and analysed with corresponding software: device 1 (Rad7 [Masimo, Irvine, CA, USA] set at 2-4sec averaging time) with software 1 (PSG 4 [Compumedics, Melbourne, Australia]) and device 2 (Wrist-Ox2® [Nonin Medical Inc, Plymouth, MN, USA] set at 3 sec averaging time) with software 2 (Noxturnal [Nox Medical Inc, Reykjavik, Iceland]). Responsiveness of each oximeter to changes in the patients’ desaturations associated with apnoeas and hypopnoeas overnight was assessed. In addition, both device SpO2 values were compared with SaO2 from simultaneous arterial blood gas sampling. Preliminary Results 7 patients (age 56.4±7.1 years, BMI 31.6±2.2 kg/m2, 100% male, 87% light skinned) were studied. The mean SpO2 with RAD7 was higher than the Nonin (95.9±1.6 vs 94.2±1.4%, mean difference 1.6±1.0%). Differences in the responsiveness of the oximeters during overnight desaturations were also observed. However, both device SpO2 values were found to be within ±2% of SaO2. Conclusions Discrepancies in SpO2 measurement do occur between devices and may have important clinical implications especially when it comes to the measurement of hypoxemic burden during sleep. 1.Blanchet MA et al. Accuracy of Multiple Pulse Oximeters in Stable Critically Ill Patients. Respir Care. 2023 May;68(5):565-574.
format Article in Journal/Newspaper
author McDermott, E
Cuesta, R
van Braak, E
Spiteri, M
Davis, S
Beranek, R
Kaur-Bains, S
Slater, B
Naughton, M
Roebuck, T
Nguy, R
author_facet McDermott, E
Cuesta, R
van Braak, E
Spiteri, M
Davis, S
Beranek, R
Kaur-Bains, S
Slater, B
Naughton, M
Roebuck, T
Nguy, R
author_sort McDermott, E
title O009 Are there Differences in SpO2 Recordings from Two Oximeters on the same hand during an Overnight Sleep Study Significant?
title_short O009 Are there Differences in SpO2 Recordings from Two Oximeters on the same hand during an Overnight Sleep Study Significant?
title_full O009 Are there Differences in SpO2 Recordings from Two Oximeters on the same hand during an Overnight Sleep Study Significant?
title_fullStr O009 Are there Differences in SpO2 Recordings from Two Oximeters on the same hand during an Overnight Sleep Study Significant?
title_full_unstemmed O009 Are there Differences in SpO2 Recordings from Two Oximeters on the same hand during an Overnight Sleep Study Significant?
title_sort o009 are there differences in spo2 recordings from two oximeters on the same hand during an overnight sleep study significant?
publisher Oxford University Press (OUP)
publishDate 2023
url http://dx.doi.org/10.1093/sleepadvances/zpad035.009
https://academic.oup.com/sleepadvances/article-pdf/4/Supplement_1/A3/52405572/zpad035.009.pdf
genre Iceland
genre_facet Iceland
op_source Sleep Advances
volume 4, issue Supplement_1, page A3-A4
ISSN 2632-5012
op_rights https://creativecommons.org/licenses/by-nc-nd/4.0/
op_doi https://doi.org/10.1093/sleepadvances/zpad035.009
container_title Sleep Advances
container_volume 4
container_issue Supplement_1
container_start_page A3
op_container_end_page A4
_version_ 1786841116443672576