Effectiveness Evaluation of Cellar Application with Controlled Temperature Mode in Low-Rise Buildings with Pile Foundations

Abstract Low-rise buildings made of light steel thin-walled structures (LSTS below) in the Arctic regions are considered by thermal protection destruction due to many heat-conducting elements and high air infiltration. Constructive measures have been recommended to increase thermal protection for bu...

Full description

Bibliographic Details
Published in:IOP Conference Series: Materials Science and Engineering
Main Authors: Kornilov, T A, Nikiforov, A Ya
Format: Article in Journal/Newspaper
Language:unknown
Published: IOP Publishing 2021
Subjects:
Online Access:http://dx.doi.org/10.1088/1757-899x/1079/6/062011
https://iopscience.iop.org/article/10.1088/1757-899X/1079/6/062011
https://iopscience.iop.org/article/10.1088/1757-899X/1079/6/062011/pdf
id crioppubl:10.1088/1757-899x/1079/6/062011
record_format openpolar
spelling crioppubl:10.1088/1757-899x/1079/6/062011 2024-06-02T08:01:55+00:00 Effectiveness Evaluation of Cellar Application with Controlled Temperature Mode in Low-Rise Buildings with Pile Foundations Kornilov, T A Nikiforov, A Ya 2021 http://dx.doi.org/10.1088/1757-899x/1079/6/062011 https://iopscience.iop.org/article/10.1088/1757-899X/1079/6/062011 https://iopscience.iop.org/article/10.1088/1757-899X/1079/6/062011/pdf unknown IOP Publishing http://creativecommons.org/licenses/by/3.0/ https://iopscience.iop.org/info/page/text-and-data-mining IOP Conference Series: Materials Science and Engineering volume 1079, issue 6, page 062011 ISSN 1757-8981 1757-899X journal-article 2021 crioppubl https://doi.org/10.1088/1757-899x/1079/6/062011 2024-05-07T14:02:47Z Abstract Low-rise buildings made of light steel thin-walled structures (LSTS below) in the Arctic regions are considered by thermal protection destruction due to many heat-conducting elements and high air infiltration. Constructive measures have been recommended to increase thermal protection for buildings made of LSTS including thermally insulated cellar with a controlled temperature mode. A comparative assessment of the energy efficiency of the proposed measures has been carried out. A significant temperature improvement on the inner surface of the basement slab was obtained. The energy characteristics improvement of a building made of LSTS is shown in comparison with the indicators of a standard solution. Article in Journal/Newspaper Arctic IOP Publishing Arctic IOP Conference Series: Materials Science and Engineering 1079 6 062011
institution Open Polar
collection IOP Publishing
op_collection_id crioppubl
language unknown
description Abstract Low-rise buildings made of light steel thin-walled structures (LSTS below) in the Arctic regions are considered by thermal protection destruction due to many heat-conducting elements and high air infiltration. Constructive measures have been recommended to increase thermal protection for buildings made of LSTS including thermally insulated cellar with a controlled temperature mode. A comparative assessment of the energy efficiency of the proposed measures has been carried out. A significant temperature improvement on the inner surface of the basement slab was obtained. The energy characteristics improvement of a building made of LSTS is shown in comparison with the indicators of a standard solution.
format Article in Journal/Newspaper
author Kornilov, T A
Nikiforov, A Ya
spellingShingle Kornilov, T A
Nikiforov, A Ya
Effectiveness Evaluation of Cellar Application with Controlled Temperature Mode in Low-Rise Buildings with Pile Foundations
author_facet Kornilov, T A
Nikiforov, A Ya
author_sort Kornilov, T A
title Effectiveness Evaluation of Cellar Application with Controlled Temperature Mode in Low-Rise Buildings with Pile Foundations
title_short Effectiveness Evaluation of Cellar Application with Controlled Temperature Mode in Low-Rise Buildings with Pile Foundations
title_full Effectiveness Evaluation of Cellar Application with Controlled Temperature Mode in Low-Rise Buildings with Pile Foundations
title_fullStr Effectiveness Evaluation of Cellar Application with Controlled Temperature Mode in Low-Rise Buildings with Pile Foundations
title_full_unstemmed Effectiveness Evaluation of Cellar Application with Controlled Temperature Mode in Low-Rise Buildings with Pile Foundations
title_sort effectiveness evaluation of cellar application with controlled temperature mode in low-rise buildings with pile foundations
publisher IOP Publishing
publishDate 2021
url http://dx.doi.org/10.1088/1757-899x/1079/6/062011
https://iopscience.iop.org/article/10.1088/1757-899X/1079/6/062011
https://iopscience.iop.org/article/10.1088/1757-899X/1079/6/062011/pdf
geographic Arctic
geographic_facet Arctic
genre Arctic
genre_facet Arctic
op_source IOP Conference Series: Materials Science and Engineering
volume 1079, issue 6, page 062011
ISSN 1757-8981 1757-899X
op_rights http://creativecommons.org/licenses/by/3.0/
https://iopscience.iop.org/info/page/text-and-data-mining
op_doi https://doi.org/10.1088/1757-899x/1079/6/062011
container_title IOP Conference Series: Materials Science and Engineering
container_volume 1079
container_issue 6
container_start_page 062011
_version_ 1800746415690874880