Test Results for Ventilation Units
Abstract The article presents the findings of the tests conducted for the forced air heating unit of a supply ventilation system. The supply air system is designed to feed clean air into the industrial facility of the oil-gas field of the Yamalo-Nenets Autonomous District. The tests were performed i...
Published in: | IOP Conference Series: Materials Science and Engineering |
---|---|
Main Authors: | , |
Format: | Article in Journal/Newspaper |
Language: | unknown |
Published: |
IOP Publishing
2021
|
Subjects: | |
Online Access: | http://dx.doi.org/10.1088/1757-899x/1079/4/042049 https://iopscience.iop.org/article/10.1088/1757-899X/1079/4/042049 https://iopscience.iop.org/article/10.1088/1757-899X/1079/4/042049/pdf |
id |
crioppubl:10.1088/1757-899x/1079/4/042049 |
---|---|
record_format |
openpolar |
spelling |
crioppubl:10.1088/1757-899x/1079/4/042049 2024-06-02T08:10:31+00:00 Test Results for Ventilation Units Mozgova, A S Shchennikova, T V 2021 http://dx.doi.org/10.1088/1757-899x/1079/4/042049 https://iopscience.iop.org/article/10.1088/1757-899X/1079/4/042049 https://iopscience.iop.org/article/10.1088/1757-899X/1079/4/042049/pdf unknown IOP Publishing http://creativecommons.org/licenses/by/3.0/ https://iopscience.iop.org/info/page/text-and-data-mining IOP Conference Series: Materials Science and Engineering volume 1079, issue 4, page 042049 ISSN 1757-8981 1757-899X journal-article 2021 crioppubl https://doi.org/10.1088/1757-899x/1079/4/042049 2024-05-07T14:02:25Z Abstract The article presents the findings of the tests conducted for the forced air heating unit of a supply ventilation system. The supply air system is designed to feed clean air into the industrial facility of the oil-gas field of the Yamalo-Nenets Autonomous District. The tests were performed in five modes at the ambient air temperatures of -5, -10, -15, -20, -25 °C. The mode throughout the tests was steady, i.e. the temperatures of water and air remained unchanged within 30 minutes before the tests. Since the capacity of the heater unit was proved to be 24 - 41.5% according to the test results, recommendations were made to improve the capacity. With the said measures having been taken, control measurements of test parameters were carried out, the actual U-value was calculated and the capacity of the heater unit was determined. The performed work is relevant in view of theoretical and practical significance for engineers and employees of industrial enterprises servicing the ventilation systems. Article in Journal/Newspaper nenets Yamalo Nenets IOP Publishing IOP Conference Series: Materials Science and Engineering 1079 4 042049 |
institution |
Open Polar |
collection |
IOP Publishing |
op_collection_id |
crioppubl |
language |
unknown |
description |
Abstract The article presents the findings of the tests conducted for the forced air heating unit of a supply ventilation system. The supply air system is designed to feed clean air into the industrial facility of the oil-gas field of the Yamalo-Nenets Autonomous District. The tests were performed in five modes at the ambient air temperatures of -5, -10, -15, -20, -25 °C. The mode throughout the tests was steady, i.e. the temperatures of water and air remained unchanged within 30 minutes before the tests. Since the capacity of the heater unit was proved to be 24 - 41.5% according to the test results, recommendations were made to improve the capacity. With the said measures having been taken, control measurements of test parameters were carried out, the actual U-value was calculated and the capacity of the heater unit was determined. The performed work is relevant in view of theoretical and practical significance for engineers and employees of industrial enterprises servicing the ventilation systems. |
format |
Article in Journal/Newspaper |
author |
Mozgova, A S Shchennikova, T V |
spellingShingle |
Mozgova, A S Shchennikova, T V Test Results for Ventilation Units |
author_facet |
Mozgova, A S Shchennikova, T V |
author_sort |
Mozgova, A S |
title |
Test Results for Ventilation Units |
title_short |
Test Results for Ventilation Units |
title_full |
Test Results for Ventilation Units |
title_fullStr |
Test Results for Ventilation Units |
title_full_unstemmed |
Test Results for Ventilation Units |
title_sort |
test results for ventilation units |
publisher |
IOP Publishing |
publishDate |
2021 |
url |
http://dx.doi.org/10.1088/1757-899x/1079/4/042049 https://iopscience.iop.org/article/10.1088/1757-899X/1079/4/042049 https://iopscience.iop.org/article/10.1088/1757-899X/1079/4/042049/pdf |
genre |
nenets Yamalo Nenets |
genre_facet |
nenets Yamalo Nenets |
op_source |
IOP Conference Series: Materials Science and Engineering volume 1079, issue 4, page 042049 ISSN 1757-8981 1757-899X |
op_rights |
http://creativecommons.org/licenses/by/3.0/ https://iopscience.iop.org/info/page/text-and-data-mining |
op_doi |
https://doi.org/10.1088/1757-899x/1079/4/042049 |
container_title |
IOP Conference Series: Materials Science and Engineering |
container_volume |
1079 |
container_issue |
4 |
container_start_page |
042049 |
_version_ |
1800756406038560768 |