Seismic resistance estimation of existing turbogenerator foundation structures under ductility level earthquake impact by nonlinear static method

Abstract The article considers the multimodal nonlinear static method as a seismic resistance estimation method of existing turbogenerator foundation structures. The object of research is the turbogenerator foundation on the Tom-Usinsk State District Power Station. The article proposes a modified al...

Full description

Bibliographic Details
Published in:IOP Conference Series: Materials Science and Engineering
Main Authors: Zubritskiy, Maksim, Ushakov, Oleg, Sabitov, Linar, Bambulevich, Maksim, Akhtyamova, Leysan
Format: Article in Journal/Newspaper
Language:unknown
Published: IOP Publishing 2021
Subjects:
Online Access:http://dx.doi.org/10.1088/1757-899x/1030/1/012028
https://iopscience.iop.org/article/10.1088/1757-899X/1030/1/012028/pdf
https://iopscience.iop.org/article/10.1088/1757-899X/1030/1/012028
id crioppubl:10.1088/1757-899x/1030/1/012028
record_format openpolar
spelling crioppubl:10.1088/1757-899x/1030/1/012028 2024-06-02T08:15:41+00:00 Seismic resistance estimation of existing turbogenerator foundation structures under ductility level earthquake impact by nonlinear static method Zubritskiy, Maksim Ushakov, Oleg Sabitov, Linar Bambulevich, Maksim Akhtyamova, Leysan 2021 http://dx.doi.org/10.1088/1757-899x/1030/1/012028 https://iopscience.iop.org/article/10.1088/1757-899X/1030/1/012028/pdf https://iopscience.iop.org/article/10.1088/1757-899X/1030/1/012028 unknown IOP Publishing http://creativecommons.org/licenses/by/3.0/ https://iopscience.iop.org/info/page/text-and-data-mining IOP Conference Series: Materials Science and Engineering volume 1030, issue 1, page 012028 ISSN 1757-8981 1757-899X journal-article 2021 crioppubl https://doi.org/10.1088/1757-899x/1030/1/012028 2024-05-07T13:58:48Z Abstract The article considers the multimodal nonlinear static method as a seismic resistance estimation method of existing turbogenerator foundation structures. The object of research is the turbogenerator foundation on the Tom-Usinsk State District Power Station. The article proposes a modified algorithm for the characteristic point search by the nonlinear static method. According to the calculations results, the existing foundation structures after a partial equipment replacement and the construction site increased seismicity are operational. Article in Journal/Newspaper Usinsk IOP Publishing Usinsk ENVELOPE(57.528,57.528,65.994,65.994) IOP Conference Series: Materials Science and Engineering 1030 1 012028
institution Open Polar
collection IOP Publishing
op_collection_id crioppubl
language unknown
description Abstract The article considers the multimodal nonlinear static method as a seismic resistance estimation method of existing turbogenerator foundation structures. The object of research is the turbogenerator foundation on the Tom-Usinsk State District Power Station. The article proposes a modified algorithm for the characteristic point search by the nonlinear static method. According to the calculations results, the existing foundation structures after a partial equipment replacement and the construction site increased seismicity are operational.
format Article in Journal/Newspaper
author Zubritskiy, Maksim
Ushakov, Oleg
Sabitov, Linar
Bambulevich, Maksim
Akhtyamova, Leysan
spellingShingle Zubritskiy, Maksim
Ushakov, Oleg
Sabitov, Linar
Bambulevich, Maksim
Akhtyamova, Leysan
Seismic resistance estimation of existing turbogenerator foundation structures under ductility level earthquake impact by nonlinear static method
author_facet Zubritskiy, Maksim
Ushakov, Oleg
Sabitov, Linar
Bambulevich, Maksim
Akhtyamova, Leysan
author_sort Zubritskiy, Maksim
title Seismic resistance estimation of existing turbogenerator foundation structures under ductility level earthquake impact by nonlinear static method
title_short Seismic resistance estimation of existing turbogenerator foundation structures under ductility level earthquake impact by nonlinear static method
title_full Seismic resistance estimation of existing turbogenerator foundation structures under ductility level earthquake impact by nonlinear static method
title_fullStr Seismic resistance estimation of existing turbogenerator foundation structures under ductility level earthquake impact by nonlinear static method
title_full_unstemmed Seismic resistance estimation of existing turbogenerator foundation structures under ductility level earthquake impact by nonlinear static method
title_sort seismic resistance estimation of existing turbogenerator foundation structures under ductility level earthquake impact by nonlinear static method
publisher IOP Publishing
publishDate 2021
url http://dx.doi.org/10.1088/1757-899x/1030/1/012028
https://iopscience.iop.org/article/10.1088/1757-899X/1030/1/012028/pdf
https://iopscience.iop.org/article/10.1088/1757-899X/1030/1/012028
long_lat ENVELOPE(57.528,57.528,65.994,65.994)
geographic Usinsk
geographic_facet Usinsk
genre Usinsk
genre_facet Usinsk
op_source IOP Conference Series: Materials Science and Engineering
volume 1030, issue 1, page 012028
ISSN 1757-8981 1757-899X
op_rights http://creativecommons.org/licenses/by/3.0/
https://iopscience.iop.org/info/page/text-and-data-mining
op_doi https://doi.org/10.1088/1757-899x/1030/1/012028
container_title IOP Conference Series: Materials Science and Engineering
container_volume 1030
container_issue 1
container_start_page 012028
_version_ 1800739945707470848