Some results of voltage increase in marine electrical propulsion installations

Abstract The main voltage parameters of marine electrical propulsion installations, at various load capacities, with further stress assessment are discussed in the article. By considering voltage options, it was revealed that an increase in inductive resistance makes it possible to manufacture a mac...

Full description

Bibliographic Details
Published in:Journal of Physics: Conference Series
Main Authors: Romanovsky, V, Nikiforov, B, Avramenko, A
Format: Article in Journal/Newspaper
Language:unknown
Published: IOP Publishing 2021
Subjects:
Online Access:http://dx.doi.org/10.1088/1742-6596/2131/5/052001
https://iopscience.iop.org/article/10.1088/1742-6596/2131/5/052001
https://iopscience.iop.org/article/10.1088/1742-6596/2131/5/052001/pdf
id crioppubl:10.1088/1742-6596/2131/5/052001
record_format openpolar
spelling crioppubl:10.1088/1742-6596/2131/5/052001 2024-06-02T08:15:11+00:00 Some results of voltage increase in marine electrical propulsion installations Romanovsky, V Nikiforov, B Avramenko, A 2021 http://dx.doi.org/10.1088/1742-6596/2131/5/052001 https://iopscience.iop.org/article/10.1088/1742-6596/2131/5/052001 https://iopscience.iop.org/article/10.1088/1742-6596/2131/5/052001/pdf unknown IOP Publishing http://creativecommons.org/licenses/by/3.0/ https://iopscience.iop.org/info/page/text-and-data-mining Journal of Physics: Conference Series volume 2131, issue 5, page 052001 ISSN 1742-6588 1742-6596 journal-article 2021 crioppubl https://doi.org/10.1088/1742-6596/2131/5/052001 2024-05-07T13:59:57Z Abstract The main voltage parameters of marine electrical propulsion installations, at various load capacities, with further stress assessment are discussed in the article. By considering voltage options, it was revealed that an increase in inductive resistance makes it possible to manufacture a machine with high power, but the quality of electrical energy in transient modes is deteriorated. During starts, reversals, resets and load surges of powerful consumers, large voltage dips will occur on the generator. To solve the problem, including determination of optimal parameters of the generator, based on the multifactorial nature of the task of creating an electric machine for a specific purpose, an analysis of all the necessary parameters was carried out. The main dimensions of the machine depend on its full power, angular speed and electromagnetic loads. The article presents technical solutions considered using the example of a modern multipurpose icebreaker-supply “Vitus Bering”. Also, as an example, an icebreaker of the Taimyr type with a limited draft is considered, for the first time in modern practice, an alternating-changing current EDMS is used. From the experience of operating the icebreakers “Taimyr” and “Vaigach”, the transition to high voltage did not lead to a complication and increase in the complexity of the maintenance of the MPM, although it required strict compliance with safety regulations during the work. During the operation of icebreakers with MPM 6.3 kV, not a single case of single-phase short circuit or electrical injury has been recorded. Article in Journal/Newspaper Taimyr IOP Publishing Journal of Physics: Conference Series 2131 5 052001
institution Open Polar
collection IOP Publishing
op_collection_id crioppubl
language unknown
description Abstract The main voltage parameters of marine electrical propulsion installations, at various load capacities, with further stress assessment are discussed in the article. By considering voltage options, it was revealed that an increase in inductive resistance makes it possible to manufacture a machine with high power, but the quality of electrical energy in transient modes is deteriorated. During starts, reversals, resets and load surges of powerful consumers, large voltage dips will occur on the generator. To solve the problem, including determination of optimal parameters of the generator, based on the multifactorial nature of the task of creating an electric machine for a specific purpose, an analysis of all the necessary parameters was carried out. The main dimensions of the machine depend on its full power, angular speed and electromagnetic loads. The article presents technical solutions considered using the example of a modern multipurpose icebreaker-supply “Vitus Bering”. Also, as an example, an icebreaker of the Taimyr type with a limited draft is considered, for the first time in modern practice, an alternating-changing current EDMS is used. From the experience of operating the icebreakers “Taimyr” and “Vaigach”, the transition to high voltage did not lead to a complication and increase in the complexity of the maintenance of the MPM, although it required strict compliance with safety regulations during the work. During the operation of icebreakers with MPM 6.3 kV, not a single case of single-phase short circuit or electrical injury has been recorded.
format Article in Journal/Newspaper
author Romanovsky, V
Nikiforov, B
Avramenko, A
spellingShingle Romanovsky, V
Nikiforov, B
Avramenko, A
Some results of voltage increase in marine electrical propulsion installations
author_facet Romanovsky, V
Nikiforov, B
Avramenko, A
author_sort Romanovsky, V
title Some results of voltage increase in marine electrical propulsion installations
title_short Some results of voltage increase in marine electrical propulsion installations
title_full Some results of voltage increase in marine electrical propulsion installations
title_fullStr Some results of voltage increase in marine electrical propulsion installations
title_full_unstemmed Some results of voltage increase in marine electrical propulsion installations
title_sort some results of voltage increase in marine electrical propulsion installations
publisher IOP Publishing
publishDate 2021
url http://dx.doi.org/10.1088/1742-6596/2131/5/052001
https://iopscience.iop.org/article/10.1088/1742-6596/2131/5/052001
https://iopscience.iop.org/article/10.1088/1742-6596/2131/5/052001/pdf
genre Taimyr
genre_facet Taimyr
op_source Journal of Physics: Conference Series
volume 2131, issue 5, page 052001
ISSN 1742-6588 1742-6596
op_rights http://creativecommons.org/licenses/by/3.0/
https://iopscience.iop.org/info/page/text-and-data-mining
op_doi https://doi.org/10.1088/1742-6596/2131/5/052001
container_title Journal of Physics: Conference Series
container_volume 2131
container_issue 5
container_start_page 052001
_version_ 1800739280414310400